Operation
Modline 5
83
Figure 75: Sensor with Laser Through the Lens Aiming Option
Laser pushbutton is located on the edge of rear panel. Visual sight is not available with this option
installed. LED above pushbutton is on when laser is energized.
See Section 5.11
, page 102 for complete Laser operation and safety instructions.
5.3
Navigation and Menus
5.3.1
Enter and Up / Down Arrow Pushbuttons
Up and Down Arrows
▼▲
are inoperative during valid temperature measurement. Arrows are
operable when an Alarm Condition has been sensed and the ALARM indicator is lit. Depressing the UP
Arrow
▲
will display an error code.
The Up Arrow should be depressed multiple times to view
simultaneous multiple Error Codes that might occur. If multiple errors have been displayed, the
Down Arrow
▼
will scroll backwards through the errors
. To return to the TEMP display while
viewing an Error Code, press Enter
. If no button is pressed after 15 seconds, the display returns to the
temperature display.
The ENT (
) pushbutton is also used to navigate from the TEMP display to the Main Setup Menus. Up
and Down Arrows
▼▲
and the ENT pushbutton are used to View, Select and Adjust Sensor Functions.
ENT (
) must be momentarily depressed (less than 5 seconds) when changing function
values and making selections. If ENT (
) is held depressed for 5 seconds, all
adjustments made in the current menu are canceled and the unit returns to the TEMP
Display.
5.4
Main Menus
Navigate from TEMP display, by pressing ENT
once. The last selected Main Menu will be displayed.
USE the UP / Down Arrows
▲▼
to step through and view the following four Main Menus. Menus are
displayed for 15 seconds before returning to the TEMP display if no further selection is made.
ENGR
(Engineering)
AOUT
(Analog Output)
COMM
(RS-485 Communications)
HEAD
(Operation Functions)
At a Main Menu, Press ENT
once to enter the Menu. One of the Function selections will be displayed.
USE the UP / Down Arrows
▲▼