background image

 

 

 

 

 

Wireless Digital Flat Panel Detector 

Mars1717XU-VSI  

User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

  

 

 Before operating, please read this user manual and pay attention to all safety precautions.   

Please ensure that this user's manual is properly maintained so that it can be accessed at any time 

( reserve ).   

Please use it correctly on the basis of full understanding of the content. 

 

Summary of Contents for Mars1717XU-VSI

Page 1: ...e operating please read this user manual and pay attention to all safety precautions Please ensure that this user s manual is properly maintained so that it can be accessed at any time reserve Please...

Page 2: ......

Page 3: ...se this product 3 The equipment should be maintained in a safe and operable condition by maintenance personnel 4 Use only computers and image display monitors complying with IEC 60601 1 or IEC 60950 1...

Page 4: ...use of this product 2 iRay shall not be liable to any damage loss or injury arising from unauthorized modifications repairs or alterations to this product or failure to strictly comply with iRay s ope...

Page 5: ...otice is used to identify conditions under which improper use of the product may cause minor personal injury This notice is used to identify conditions under which improper use of the product may caus...

Page 6: ...s symbol is used to indicate the name and address of the manufacturer the date of manufacture can be combined in this symbol This symbol is used to indicate consultation of the user guide for general...

Page 7: ...B type applied part Handled with care Caution refer to appending files for important information about safety such as warnings and matters needing attention which is not suitable to be shown on the in...

Page 8: ...1717XU Wireless Digital Flat Panel Detector User Manual 6 iRay Technology Co Ltd Package symbol do not roll the transportation package Package symbol this symbol is used to indicate stacking limit num...

Page 9: ...OPERATION 38 4 1 Main Operation 39 4 2 Block diagram 39 4 3 Work Flow 40 4 4 Description of workflow 40 5 REGULATORY INFORMATION 42 5 1 Registrant Information 43 5 2 Manufacturer Information 43 5 3 Me...

Page 10: ...ser Manual 8 iRay Technology Co Ltd 7 TROUBLE SHOOTING 55 8 SERVICE INFORMATION 56 8 1 Product lifetime 57 8 2 Regular inspection and Maintenance 57 8 3 Repair 58 8 4 Replacement parts support 58 APPE...

Page 11: ...1 Safety Information iRay Technology Co Ltd 9 1 Safety Information 1 1 Safety precautions 10 1 2 Notes for Using 14...

Page 12: ...h as medical equipment on cables and cords Do not pull bend bundle or step on them to prevent their sheath from being damaged and do not alter them neither Doing so may damage the cords which could re...

Page 13: ...alfunction of the equipment When a problem occurs Should any of the following occurs immediately unplug the power cord of Control Box and contact your sales representative or local iRay dealer When th...

Page 14: ...Otherwise it may cause a malfunction of the equipment or injury of the user due to tripping over the cable Power supply Always connect the three core power cord plug to a grounded AC power outlet To...

Page 15: ...function Be sure to use the equipment on a flat surface so it will not bend Otherwise the internal image sensor may be damaged Be sure to securely hold the detector while using it in upright positions...

Page 16: ...l image is acquired after exposure accomplished Due to disturbance from a device which does not complied with IEC60601 1 2 standard functions of the product are abnormal which results in no valuable c...

Page 17: ...ure or it may cause image noise or artifacts even incorrect images Do not use the devices near the equipment generating a strong magnetic field Otherwise it may cause image noise artifacts or even inc...

Page 18: ...d Product Components 18 2 5 Components Description 19 2 5 1 Detector 19 2 5 2 Power Supply 20 2 6 Product Specification 20 2 6 1 Detector 20 2 6 1 1 Basic 20 2 6 1 2 MTF 21 2 6 1 3 DQE 21 2 6 2 Power...

Page 19: ...es Mars1717XU a real portable panel 2 1 Scope This manual contains information about the iRay Mars1717XU All operators must read and understand this manual before using equipment All information in th...

Page 20: ...717XU intended use and the result of risk management identifying and describing the essential performance as the following a To perform communication and instruction transmission between the flat plan...

Page 21: ...A DC Input Interface DC input B Detector Indicator Power Internet Connection Status C Detector indicator of detector D Button Power button Reset Switch hole E Front surface film In line with biologic...

Page 22: ...Sensor a Si Amorphous Silicon TFT Pixel Size 139 m Pixel Matrix 3072 x 3072 Effective Area H x V 427 x 427 mm Greyscales 16bit Spatial Resolution 3 6 Lp mm Preview Acquisition Time Client 5GHz 2 5 se...

Page 23: ...Spatial Frequency lp mm MTF CsI 1 0 0 65 2 0 0 43 3 0 0 17 2 6 1 3 DQE Spatial Frequency lp mm RQA5 DQE CsI 2 5uGy 0 0 65 1 0 0 45 2 0 0 30 3 0 0 20 2 6 2 POWER SUPPLY Mars1717XU supports both DC and...

Page 24: ...ge 2 400 2 4835 GHz and 5 15 5 25 GHz 5 725 5 85 GHz Wireless Data Rate 802 11b Max 11Mbps 802 11a g Max 54Mbps 802 11n Max 300Mbps MIMO 2x2 2 6 4 WIRELESS COMMUNICATION Item Description Wireless Stan...

Page 25: ...Hard Disk 640 G LAN Card Intel Pro EXP9301CT PRO 2 6 6 USE ENVIRONMENT Operating Storage Temperature 5 35 30 55 Temperature change 1k min 1k min Humidity 30 80 RH 10 90 RH Atmospheric Pressure 700 10...

Page 26: ...c power 25 3 1 1 booting up 25 3 2 Software Installation 27 3 3 Detector Configuration 27 3 3 1 AP Mode 27 3 3 1 1 External Wireless LAN Setting 27 3 3 1 2 AP Mode Detector Configuration 29 3 3 2 Clie...

Page 27: ...f detector is powered off users can press the button for 3 seconds to power on the detector when a Lithium ion capacity is inserted and the Lithium ion capacitor is no less than 20 or direct current p...

Page 28: ...ter Orange ON with 1sec Power OFF 20 NO OFF after Green ON with 1sec Power OFF 20 NO Link indicator D shows as following LINK Indicator Lighting Status Description OFF Shut down Wired Wireless connect...

Page 29: ...tribute package NET Framework IDetector should not be used for terminal hospital 1 Install Microsoft NET Framework 4 5 before first use which needs to be downloaded from the Microsoft website 2 Need t...

Page 30: ...ars1717XU Wireless Digital Flat Panel Detector User Manual 28 iRay Technology Co Ltd Open the wireless signal list Select SSID belong to the detector and input the password Open wireless network statu...

Page 31: ...setting IP setting Network mask setting IP address 192 168 8 188 Subnet mask 255 255 255 0 Open SDK select a corresponding product and start connection by clicking connect 3 3 1 2 AP MODE DETECTOR CON...

Page 32: ...30 iRay Technology Co Ltd Click Detector button of IDetector software Click wifi button Select AP mode 1 Click Read Config button to read the default setting 2 Change SSID and password setting to make...

Page 33: ...3 Installation and Operation iRay Technology Co Ltd 31 Change the channel and frequency settings Click Chanel to select a clean wireless frequency and channel Click write Config...

Page 34: ...n the detector is power on next time 3 3 2 CLIENT MODE The user needs to complete the wireless client mode configuration according to the following operation When different detectors are used it is st...

Page 35: ...3 Installation and Operation iRay Technology Co Ltd 33 Open Local network configuration Open IPV4 setting IPSetting Network mask setting Select Obtain an IP address automatically...

Page 36: ...ugh the interface Wireless setup Configure 2 4GHz wireless network SSID NETGEAR_BIG_24 For example set up a wifi named Mars2 4G Security WPA2 PSK Password 12345678 Channel Please check the current Wi...

Page 37: ...lean channel LAN Setup Configure LAN IP address IP address 192 168 100 1 Subnet Mask 255 255 255 0 External Wireless AP Reboot Apply above settings and reboot your wireless router Recover Local Networ...

Page 38: ...ctor through wireless network card under AP mode of the detector Click Detector button of IDetector Click wifi button and Read Config button Select Client mode Change the default wireless router SSID...

Page 39: ...3 Installation and Operation iRay Technology Co Ltd 37 Reconnect IDetector and the flat panel detector Enter acquisition interface to set up connection...

Page 40: ...4 Operation iRay Technology Co Ltd 38 4 Operation 4 1 Main Operation 39 4 2 Block diagram 39 4 3 Work Flow 40 4 4 Description of workflow 40...

Page 41: ...eration of Mars1717XU Most importantly detector should build synchronization with X ray generator Mars1717XU is born with PREP_ACQ2 Mode to acquire X ray image 4 2 Block diagram Software mode is the b...

Page 42: ...on informs GCU I O Box to control high voltage generator to start anode rotation Push down hand switch I button GCU informs high voltage exposure preparation meanwhile informs the Panel to prepare for...

Page 43: ...tion to GCU and then corresponding information will be shown in IDetector information bar and the user is noticed that the detector is ready to receive X ray 7 GCU receives Exposure to start generatin...

Page 44: ...l equipment safety standards 43 5 4 References harmonized standards under Directive 93 42 EEC 44 5 5 Guidance and manufacture s declaration for EMC 45 5 6 Lithium ion Capacitor Reference Standards 47...

Page 45: ...ng Hi tech industrial district Pudong Shanghai PRC 201201 Production Address Room 202 Building 9 No 590 Ruiqing Rd East area of Zhangjiang Hi tech industrial district Pudong Shanghai PRC 201201 Contac...

Page 46: ...ical device Application of risk management to medical devices IEC 60601 1 2005 Amendment 1 2012 EN 60601 1 2006 Amendment 1 2013 Medical electrical equipment Part 1 General requirements for basic safe...

Page 47: ...Class B Professional healthcare facility environment Harmonic distortion IEC 61000 3 2 Class A Professional healthcare facility environment Voltage fluctuations and flicker IEC 61000 3 3 Compliance P...

Page 48: ...5 780 810 800 960 Pulse modulation 18Hz 28V m 870 930 1720 1700 1990 Pulse modulation 217Hz 28V m 1845 1970 2450 2400 2570 Pulse modulation 217Hz 28V m 5240 5100 5800 Pulse modulation 217Hz 9V m 5500...

Page 49: ...y unsafe situation Mars1717XU conforms to this EN60601 1 2 2015 standard for both immunity and emissions Nevertheless special precautions need to be observed The use of accessories transmitters and ca...

Page 50: ...HOUSING LABEL 5 8 Radio Frequency Compliance Information 5 8 1 SRRC COMPLIANCE This equipment has been tested and found to comply with CMIIT ID 2017AP3876 of SRRC Rules These limits are designed to p...

Page 51: ...ifferent from that to which the receiver is connected Consult the distributor or an experienced X ray technician for help 5 9 INFORMATION TO USER The users manual or instruction manual for an intentio...

Page 52: ...AND USED IN ACCORDANCE WITH THE INSTRUCTIONS MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS HOWEVER THERE IS NO GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR INSTALLATION IF THIS...

Page 53: ...6 Software Opeartion Information iRay Technology Co Ltd 51 6 Software Operation Information 6 1 Default Settings 52...

Page 54: ...el_3_L 30 normal operation low power warning forbid exposure Battery_Level_4_H 29 forbid use the system needs shut down 20 auto shut down Battery_Level_4_L 0 Wireless Signal_Split_1 70 normal operatio...

Page 55: ...300 Cfg_TotalAcqTimeout 30000 Cfg_PreExpImageAcqTimeout 1000 Cfg_CleanupProcessTime 2000 FactoryParameters Product No 45 Product No 45 Sub Product No SubProductNo_CsI550 Serial No VT36xxxxxxxxx Main V...

Page 56: ...on A4 Date 2017 08 23 Prep CapMode PrepCapMode_Acq2 Self CapEnable On Integrate Time ms 776 Self Clear Span Time us 100 Sequence Interval Time ms 8000 Tube Ready Time 500 Set Delay Time ms 600 Exp Win...

Page 57: ...7 Trouble Shooting iRay Technology Co Ltd 55 7 Trouble Shooting This section is detailed in the Mars1717XU service manual...

Page 58: ...ctor User Manual 56 iRay Technology Co Ltd 8 Service Information 8 1 Product lifetime 57 8 2 Regular inspection and Maintenance 57 8 2 1 Daily inspection 57 8 2 2 Monthly and annual inspection 57 8 3...

Page 59: ...ach two months during storage 8 2 1 DAILY INSPECTION Before and after using this product following inspections should be taken Item Operation Detector Ensure the detector has no screw loosening or cra...

Page 60: ...sed to the minimum if the user follow this manual to do maintenance on time However if a problem cannot be solved even taking the measures indicated in troubleshooting contact your sales representativ...

Page 61: ...Appendix iRay Technology Co Ltd 59 Appendix Appendix A Information of Manufactures 60...

Page 62: ...f Manufactures COMPANY iRay Technology Co LTD ADDRESS Rm202 Building 7 No 590 Ruiqing Rd Zhangjiang East Pudong New Area Shanghai China ZIP CODE 201201 TELEPHONE 86 21 50720560 FAX 86 21 50720561 HOME...