©2011 IQtronic, Ltd
Page 24 of 34
SMS Command
Description
SMS Response
Type
NEXTTESTTIME=1
Next activation of the input alarm is
possible after 1 minute.
NEXTTESTTIME=1
- OK
Cfg
NEXTTESTTIME?
Get current settings of Input1 time
delay
NEXTTESTTIME=1
minutes
Cfg
If an input alarm state occurs sooner than is
NEXTTESTTIME
value, alarm will
be activated after expiring of
NEXTTESTTIME
time. Setting
NEXTTESTTIME to
zero (0) value deactivated this option.
Defining which input state causes alarm activation
Input alarm can be activated by:
o
change of the input state, or
o
by existence of one from possible states Log.0 (inactive, false, L-low, no
voltage appears at the input pin or Log.1 (active, true, H-high, voltage
higher than threshold appears at the input pin).
This behavior is configured by command
INPUTTYPE
:
SMS Command
Description
SMS Response
Type
INPUTTYPE=CHANGE Alarm is activated at every change
of input state
INPUTTYPE=CHANGE
- OK
Cfg
INPUTTYPE=HIGH
Send alert SMS every time when
remaining battery charge falls below
defined threshold 50%.
INPUTTYPE=HIGH- OK
Cfg
INPUTTYPE=LOW
Disable sending remaining battery
charge alerts
INPUTTYPE=LOW- OK
Cfg
INPUTTYPE?
Get configuration of INPUTTYPE,
active setting is in () parentheses.
INPUTTYPE =(CHANGE),
HIGH, LOW
Cfg
Activation of the input alarm
Alarm detection at the input can be activated by the
INPUTALARMON/INPUTALARMOFF
commands:
SMS Command
Description
SMS Response
Type
INPUTALARMON
Input alarm is activated
INPUTALARMON
- OK
Ctrl
INPUTALARMOFF
Input alarm is deactivated
INPUTALARMOFF
- OK
Ctrl
Note…
While attempting to activate input alarm, you can receive
following error messages:
ALARM – no sensor
there is nothing connected to the input
jack
ALARM – no number
there is no phone number defined for
alerts