Page 16 of 60
3.5.9.
Input/Output control
Name
OID Value
Description
LED activity
1.2.17
Determines what the camera LED will represent. Options are OFF,
ACTIVITY and ON.
LED2 activity
2.45
Determines what the camera LED will represent. Options are
ENABLED, DISABLED and TIMEOUT.
Input state
1.3.15
Defines how the input from an attached device will cause a trigger.
Options are ONOPEN and ONCLOSE.
Simulate input
trigger
1.3.10
Writing this write only OID with the value
“
1
”
will cause a trigger
event just as if the input trigger activated.
Output relay state
1.3.5.1
Defines the normal (inactive) state of the output relay. Options are
OPEN and CLOSED.
Output relay
duration
1.3.5.2
Defines how long the output relay will be held in the active state
when triggered. Values can range from 1 to 60 seconds.
Simulate output
trigger
1.3.11
Writing this write only OID with the value
“
1
”
will active the output
relay.
Last trigger was
closed
1.3.17
This read only OID will return the time of the last trigger event in
seconds since the epoch. (1/1/1970 GMT)
Activate output
relay
17.4
TBD
3.5.10.
Motion windows
Name
OID Value
Description
Left edge
1.11.1.1.n
Left edge of motion window <n> in pixels.
Top edge
1.11.1.2.n
Top edge of motion window <n> in pixels.
Width
1.11.1.3.n
Width of motion window <n> in pixels.
Height
1.11.1.4.n
Height of motion window <n> in pixels.
Include window
1.11.1.5.n
Specifies if window <n> is type include, meaning use this window
for detecting motion. Options are
“
ON
”
and
“
OFF
”
.
Exclude window
1.11.1.6.n
Specifies if window <n> is type exclude meaning do not detect
motion in this area. Options are
“
ON
”
and
“
OFF
”
Enable
1.11.1.7.n
Specifies if window <n> should be used. Options are
“
ENABLED
”
and
“
DISABLED
”
Sensitivity
1.11.1.8.n
Specifies how sensitive window <n> should be for detecting motion.
Values range from 0 to 254. The default value is 0 which means
automatic sensitivity adjustment based on lighting conditions.
Percentage of
window
1.11.1.9.n
Specifies how many of the pixels in window <n> must change for
motion to be detected. Values range from 1% to 100%.
Remove all
windows
1.11.4
Writing this write only OID will reset the motion windows to their
factory default state.
Not all motion window OIDs are available for all camera models. See Section 3.6.10,
“
Motion Windows
Support
”