IQAir GC series User Manual Download Page 10

11

Chapter 4 – Using the Control Panel

4.1.1 Description of Control Panel Keys

Power Key
The Power key switches the IQAir® ystem on and off. When the system is switched off, the fan stops to run, but

the system will remain connected to the power supply (standby mode).The standby mode allows for automatic timer
start-up. In the standby mode, the different menu functions can be accessed.
Tip: In a menu window the Power key also serves as a quick exit key to return to the main display window.

Arrow (

) Key

When the system is switched on, the

key allows the adjustment of the fan speed. In the enter mode, indicated

by the appearance of a black flashing cursor (see “Enter Key” below), the

key is used to modify the selected setting

in the display window. Confirmed with the Enter key, the enter mode is automatically terminated. The LCD will then
display the current menu settings for another 15 seconds before reverting to the main window display.

Chapter 4 – Using the Control Panel

The IQAir system is operated and controlled via the electronic control panel which is located at the top of the front
locking arm.

Several operations can be completed via the electronic control panel, including:

Switching the system on and off

Controlling the fan speed and corresponding air delivery rate

Checking the remaining filter life of the individual filters

Setting the automatic timer

Resetting the Filter Life Monitor after replacing a filter

Locking the control panel to avoid tampering with the system’s settings

Choosing the desired display language

4.1 Description of Control Panel Elements

LCD = Liquid
Crystal Display

Power

Key

Enter

Key

Menu

Key

Arrow

Key

Filter Life LED: Filter 3

Filter Life LED: Filter 2

Pre-filter Life LED: Filter 1

Timer LED

Fan Speed LEDs

LCD Display

The 2-line LCD displays important information about the system’s settings. In
standby mode, the first line shows the current day and time. If the timer is
activated, the programmed start and stop times will be displayed on the second
line.

If the IQAir system is on, the first line displays the current speed setting and the
second line displays the corresponding air delivery rate of the system. By
pressing the Menu key, ten active menu functions may be accessed. These
functions are explained in detail in this chapter.

LED = Light Emitting Diode

Main window: Standby mode

Main window: On mode

Menu window: Filter Life monitor

All manuals and user guides at all-guides.com

Summary of Contents for GC series

Page 1: ...GC Series High Performance Air Cleaning System User s Manual HB GCSer_GB_0407 105 10 35 12 Swiss Made All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...appliances Only use this appliance for its intended purpose of air cleaning in non industrial environments Do not use this appliance in areas with very high concentrations of dusts or powder to preven...

Page 3: ...4 4 Setting the Weekly Timer 16 4 4 5 Timer ON OFF Fan Speed Selection 16 4 4 6 Timer Information in the Control Panel 17 4 4 7 Time Day Setting 17 4 4 8 Filter Life Reset 18 4 4 9 Changing Airflow Un...

Page 4: ...air is high or the indoor air quality requirements are stringent the hourly air delivery of the system needs to exceed the room air volume several times To achieve that level of air turnover it may b...

Page 5: ...equest we will also keep you up to date with technical and promotional information relating to this air cleaning system The shell and serial numbers are located at the base of the system IQ HB ZB 3yGa...

Page 6: ...a soft and clean surface Place the mounting rail on the purifier s base so that the holes line up with the black connector pins on the base The cut ins should face the center of the unit Press down u...

Page 7: ...a cupboard In general the more centrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cable is positioned in a way that...

Page 8: ...e Pre Filter which is fixed inside the frame by four filter clamps The fan assembly comprises two housing modules with the centrifugal fan inside The Frame module 2 consists of frame 2 and a steel bas...

Page 9: ...ate post filter sleeves hold back abrasion particles from the gas phase filter media 6 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 3 2 Description of Removable Co...

Page 10: ...ions can be completed via the electronic control panel including Switching the system on and off Controlling the fan speed and corresponding air delivery rate Checking the remaining filter life of the...

Page 11: ...matically either due to a reduction in airflow particle filters are clogged or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through t...

Page 12: ...cific environment are calculated as follows hourly air delivery of the IQAir system m3 h air changes per hour ACH air volume of the room m3 N B The air delivery rates at the various fan speeds setting...

Page 13: ...memory bank which contains infor mation about the different filters lives under specific conditions of use The Filter Life Monitor makes a calculation of the remaining filter life taking into account...

Page 14: ...the Menu key twice 2 Press and hold the Enter key until the cursor starts to flash 3 Press the key once to activate the timer Note If the start and stop time are identical the timer cannot be activat...

Page 15: ...de 4 4 4 Setting the Weekly Timer The weekly timer allows the activation deactivation of the Timer ON period on certain days of the week In its default setting the timer is enabled on all seven days o...

Page 16: ...ursor starts to flash 3 Select the hour by pressing the key 4 Press the Enter key to save the hour setting and to proceed to the minute setting 5 Select the minutes by pressing the key 6 Press the Ent...

Page 17: ...urrent display language is displayed 2 To change the display language press and hold the Enter key until the cursor starts to flash 3 Use the key to scroll through the display language options 4 Press...

Page 18: ...small combustion particles that are created as the result of combustion processes of automobiles small allergen particles such as cat allergens tobacco smoke particles etc 4 4 11 1 Determining the Fil...

Page 19: ...environment where the system is used for guidance see previous section 8 Press the Enter key to save the Chemical index setting 9 Press the key to preceed to the Fine Dust index 10 Press and hold the...

Page 20: ...e timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch the timer off press the Timer Modification key and then the Timer...

Page 21: ...the IQAir system on the right side of the control panel shows the positions of the individual filters These positions correspond to the actual positions of the filters within the system 6 2 Ordering...

Page 22: ...ush the locking arms inwards simultaneously until they snap back into the housing 23 Chapter 6 Replacing Filters Opening Closing 6 3 1 Troubleshooting when closing the Housing If the IQAir system does...

Page 23: ...1 Open the locking arms remove the diffuser and frame 3 2 Frame 2 contains the four gas phase filter cartridges with the four post filter sleeves Remove frame 2 with the cartridges 3 Twist each cartri...

Page 24: ...ocal regulations and laws Chapter 7 Maintenance 7 1 Cleaning the Housing Unplug the IQAir system before attempting to clean it Use a soft and clean cloth for cleaning For water soluble stains use a wi...

Page 25: ...ting of the IQAir system where floor space is limited InFlow Complete ducting adapter kit for the creation of positive pressure if placed within the room and negative pressure if placed outside the ro...

Page 26: ...INCEN AG Blumenfeldstrasse 15 CH 9403 Goldach Switzerland Tel 41 71 844 0844 Fax 41 71 844 0845 email info incen com www iqair com All manuals and user guides at all guides com a l l g u i d e s c o m...

Reviews: