CONNECTION DIAGRAM
Isolation
Switch
Mains
Supply
Ensure that all connections are secure.
Ensure the terminal block is attached to its mounting posts in the sensor body.
Un-hook the sensor unit from the wall plate and re-attach to the wall plate box as follows:-
Ensure no wires are trapped.
Align the sensor centrally over the wiring box and attach the top edge of the sensor to the wall
plate. see diagram I. There will be an audible click indicating that the top clips are located into the
wallplate.
Slowly rotate the sensor body downwards and and ensure no wires are trapped, the lower edge of
the unit will locate into the wallplate.
Fullly tighten the fixing screw. See diagram F.
Installation is complete.
MANUAL OVERRIDE MODE
The light can be switched on for longer time periods by use of the
Manual Override Mode
. This
can be activated at night by using the internal wall switch or circuit breaker.
Switch the internal wall switch/circuit breaker off/on off/on within 1 second. The unit will now
illuminate continuously until dawn or until it is switched back into
Auto Mode
.
To switch the unit back into
Auto Mode
, flick the internal wall switch/circuit breaker off/on once
within 20 seconds. The unit will return to
Auto Mode
.
Security
Load
Max 1000W
Courtesy
Load.
Max 120W
Common