SECTION FIVE
TECHNICAL SPECIFICATIONS
Detection Range
Detection Angle
Power Supply
Lamp type
Maximum Switchable Load
Time On Adjustment
Dusk Level Adjustment
Environmental Protection
Up to 12 metres
200º
240 V AC ~ 50Hz
IQ-OEMCTV-200-150
240V Linear Tungsten Halogen 150W max (R7S cap)
IQ-OEMCTV-200-500
240V Linear Tungsten Halogen 500W max (R7S cap)
2000W (4 x 500W) Tungsten Halogen
1000W (10 x 100W GLS) Incandescent
500W Fluorescent
5 seconds - 5 minutes
Day & night or night only operation
IP44 (suitable for outdoor use)
MANUAL OVERRIDE MODE
At night
, to switch the unit into manual override mode, turn the power off/on/off/on (twice) within 1
second,using the internal wall switch/circuit breaker. The unit should now enter manual override
mode until dawn when it will reset to its normal operation. The lamp will illuminate at full power
until dawn.
To reset back to Auto mode, turn off the power again and wait 20 seconds. Switch back on. The
unit will go through its warm-up cycle before resuming normal PIR operation.
Halogen Lamp Replacement
CAUTION
Always handle quartz halogen bulbs with a soft cloth. Do not touch the bulb with your bare hand,
as it will shorten the life of the bulb.
1. Switch off the floodlight. Do not touch the Floodlight while it is in use or still hot. Allow it to cool
(about 5 minutes) before touching it.
2. Replacement bulb type is 240V mains halogen 150W or 500W R7S cap floodlight bulb.
3. Isolate the mains supply and then unscrew cover screw on the top of the unit.
4. Open the glass cover. The cover is mounted on hinges and will swing open.
5. To remove existing bulb, depress then lift one end of the bulb to remove.
6. Install new bulb by inserting one end first and depressing gently until enough clearance is
gained to seat the other end in the socket. Rotate the bulb to ensure it is properly seated.
Warning!
In the event of the cover glass shattering, do not replace with normal household glass.
Do not operate without the glass shield in place. If the glass shield is cracked or damaged, it
must be replaced. If the glass is replaced, use only tempered glass of equal thickness
SF-OEMCTV200-150&500-GR.qxd 16/05/2005 11:21 Page 9