PIERCE & PASS THE CABLE THROUGH THE GROMMET BEFORE PROCEEDING.
It is recommended that the grommet is pierced with a screwdriver to ensure a better seal.Allow
approximately 50mm of cable to pass through the grommet. 

Fit the grommet into its location, ensuring a good seal.  

Fix the mounting plate to the wall.  Take care not to overtighten the screws to prevent damage to
the mounting plate.  If using a power screwdriver, use the lowest torque setting.

Fit the lamp
The Lantern can be suspended below the wall bracket to ease installation. Simply turn the
lantern as Diagram E and clip the lantern onto to the hook on the inside of the wall plate. The
lantern will now be restrained to aid cable connection.

CONNECTION

Connect the cable to the terminal block on the unit as
follows (see connection diagram): 
NEUTRAL (Blue)  

N      

EARTH (Green/Yellow) 
LIVE (Brown)  

L

Ensure that the connections are secure.
Ensure no wires are trapped. 
Refit the wall antern to the bracket (reversal of
diagram C) ensuring the lower clip is firmly located.

Clip the lantern top to the lantern ensuring the clips and location marks on lantern top are
aligned. See Diagram F.

Isolation 
Switch

A

LUX

Time

dusk/
dawn

2

4

8

IQ-PCL-PH-13-6-B.qxp  14/12/2006  10:52  Page 4

Summary of Contents for E-294B

Page 1: ... E 13W Low Energy Lantern E 294B Version 1 12 06 IQ PCL PH 13 6 IQ Europe Limited Sandbeck Lane Wetherby LS22 7TW Visit us at www iq europe co uk Installation helpline 0871 717 1100 IQ PCL PH 13 6 B qxp 14 12 2006 10 52 Page 1 ...

Page 2: ...ility of the buyer to prove delivery to IQ The product has been bought by the user The product has not been misused or handled carelessly installed incorrectly or used on a voltage supply other than that shown on it Repairs have not been attempted by anyone other than IQ s staff The product has been used for domestic purposes only The product has not been installed in any unusually exposed or hars...

Page 3: ...s screwdriver Wire cutters IMPORTANT As of 1 January 2005 changes to the Building Regulations affect domestic electrical installations in England and Wales You don t need to be a qualified electrician to make changes to your home s electrical system but the work must be done in accordance with the Regulations Where you employ an electrician who is a member of a competent person self certification ...

Page 4: ...t to ease installation Simply turn the lantern as Diagram E and clip the lantern onto to the hook on the inside of the wall plate The lantern will now be restrained to aid cable connection CONNECTION Connect the cable to the terminal block on the unit as follows see connection diagram NEUTRAL Blue N EARTH Green Yellow LIVE Brown L Ensure that the connections are secure Ensure no wires are trapped ...

Page 5: ...off baseplate to release lantern 2 C 1 1 Release lower edge of wall bracket from lantern 2 Lift lantern off wall bracket to release from locating pillars Locating holes and pillars IQ PCL PH 13 6 B qxp 14 12 2006 10 52 Page 5 ...

Page 6: ... to carefully prise 2 x clips on underside of lantern lid to release this mark on the lid above clip location identifies the position of the clips to aid re assembly F D wall fixing holes cable inlet E IQ PCL PH 13 6 B qxp 14 12 2006 10 52 Page 6 ...

Page 7: ...At this position the unit should become operative at approximately the same level of darkness each evening Observe the operation of the unit If the unit is starting to operate too early ie when it is quite light adjust the control slightly anti clockwise If the unit starts to operate too late ie only when it is very dark adjust the control slightly clockwise Continue to adjust until the unit opera...

Page 8: ...eration at the current DUSK setting During the hours of darkness adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details Adjust the setting anti clockwise to lower the level of ambient light required for activation If you experience problems refer to Troubleshooting Guide If problems still exist do not immediately return the unit to store Tele...

Page 9: ...oyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the li...

Reviews: