Specification Parameters:
Input Voltage
12VDC
Operation
Environment
No-condensation 20-90% RH
,
-20
℃~
40
℃
Wattage
40W
Working
Range
Up to 5m in a cone of 120
degrees
Mounting Hole
Spacing
60mm
Matching
Box
75mm x 75mm x 50mm
Dimension
86mm x 86mm x 43mm
Weight
72g
Wiring Diagram and Installation Guide:
BRT-319 occupancy sensor switch is powered by 12V DC supply:
In+
:
Coming from the positive of power supply;
In-
:
Coming from the negative of power supply; and
Load wires:
Going to the load.
Fig. 3
BRT-319 Wiring Diagram
Fig. 3 shows the wiring diagram and Fig. 4 shows the step-by-step installation instructions. There
are three easy steps:
Step one:
Use a screwdriver to pry off the front plate in position A;
Step two:
Wiring according to the diagram and the labelled ports of the switch; and
Step three: Install screws and front plate.