© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Washer-Extractors
38
5-08-51
Anchoring to Concrete Base
The machine must be anchored directly to concrete
base. Refer to
Figure 23
.
Figure 23
IMPORTANT: Machine bolt should be re-checked
on a quarterly basis.
CHM2104N
1
Nut
.625 in. (M16)
2
Washer
1.57 in. x 0.60 in. x 0.15 in.
(40 mm x 17 mm x 4 mm)
3
Bolt
.625 in. (M16)
4
Concrete Base
15.74 in. (400 mm) (Models IWF033 and
IWF040), and 21.65 in. (550 mm)
(Model IWF055), and 27.55 in. (700 mm)
(Model IWF075)
5
Machine Base
CHM2104N
5
1
2
3
4