background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Tumblers – 120 and 170

4

4-08-45

Specifications and Dimensions

N/A = Not Applicable

Specifications

120 Pound

170 Pound

Noise level measured during operation 

at operator position of 3.3 feet (1 meter) 

in front of machine and 5.2 feet 

(1.6 meters) from floor.

66 dBA

66 dBA

Cylinder Size:

Inches (mm)

44 x 41 

(1118 x 1041)

50.75 x 42.5

(1289 x 1080)

Cylinder Capacity dry weight:

Pounds (kg)

120

(54.4)

170

(77.1)

Cylinder Motor Horsepower

0.75

0.75

Fan Motor Horsepower

1

3

Air Outlet Diameter:

Inches (mm)

10 

(254)

12

(300)

Maximum Static Back Pressure:

W.C.I. (mbar)

0.3

(0.8)

0.3

(0.8)

Maximum Airflow: 

C.F.M (L/sec.)

1600

(755)

2450

(1156)

Gas Models

Net Weight (approximate):

Pounds (kg)

1275

(580)

1575

(716)

Gas Connection

3/4 in. NPT

1 in. NPT

Gas Burner Rating:

Btu/hr. (Mj/hr.)

300,000

(316)

395,000

(421)

Steam Models

Net Weight (approximate):

Pounds (kg)

1375

(625)

1675

(761)

Steam Connection

3/4 in. NPT inlet

3/4 in. NPT outlet

3/4 in. NPT inlet

1 in. NPT outlet

Steam Coil Rating at 100 psig:

Boiler Horsepower (Btu/hr.)

(recommended operating pressure 

80-100 psig)

11.7

(405,000)

18.8

(648,000)

Summary of Contents for 120

Page 1: ...Refer to Installation manual for full instructions 4 08 45R4 June 2011 On Premise Laundry Planning Handbook 120 and 170 Pound Tumblers Through Serial No 0907000048 TMB1268C TMB1268C ...

Page 2: ...lers 120 and 170 2 Introduction 2 Model Identification 2 Specifications and Dimensions 4 120 Pound Tumbler Dimensions and Exhaust Outlet Locations 5 170 Pound Tumbler Dimensions and Exhaust Outlet Locations 6 Electric and Gas Connection Locations for Gas Models 7 Electric and Steam Connection Locations for Steam Models 8 Installation 9 Pre Installation Inspection 9 Tumbler Enclosure 10 Exhaust Req...

Page 3: ...del Identification Includes models with the following control suffixes TMB1268C TMB1268C Gas Steam Thermal Oil 120 Pound IPD120G2 IT120L IPD120G2 IT120N IPD120S2 IT120S IPD120S2 IT120T 170 Pound IPD170G2 IT170L IPD170G2 IT170N IPD170S2 IT170S IPD170S2 IT170T RD reversing DMP OPL RQ reversing dual digital timer ...

Page 4: ...e Multiply By To Obtain Multiply By To Obtain Btu 0 252 kCal Pounds sq inch 0 06895 Bars Btu 1055 Joules Pounds sq inch 0 070 kg sq cm Inch 25 4 Millimeters Pounds lbs 0 454 Kilograms Inches W C 0 036 Pounds sq inch Boiler Horsepower 33 479 Btu hr Inches W C 0 249 kPa Boiler Horsepower 34 5 lbs steam hr lb inch2 psi 6 895 kPa CFM 0 471 liters second ft 3 28 32 Liters kW 3414 Btu hr ...

Page 5: ...4 170 77 1 Cylinder Motor Horsepower 0 75 0 75 Fan Motor Horsepower 1 3 Air Outlet Diameter Inches mm 10 254 12 300 Maximum Static Back Pressure W C I mbar 0 3 0 8 0 3 0 8 Maximum Airflow C F M L sec 1600 755 2450 1156 Gas Models Net Weight approximate Pounds kg 1275 580 1575 716 Gas Connection 3 4 in NPT 1 in NPT Gas Burner Rating Btu hr Mj hr 300 000 316 395 000 421 Steam Models Net Weight appro...

Page 6: ... H I 120L N 31 38 in 797 mm 32 5 in 826 mm 48 91 in 1242 mm 49 91 in 1268 mm 67 92 in 1725 mm 45 38 in 1153 mm 46 38 in 1178 mm 85 7 in 2177 mm 70 in 1778 mm 120S 31 38 in 797 mm 32 5 in 826 mm 48 91 in 1242 mm 49 91 in 1268 mm 67 92 in 1725 mm 45 38 in 1153 mm 46 38 in 1178 mm 83 5 in 2121 mm 70 in 1778 mm Exhaust Outlet Dimensions and Locations Models U V W X Y Z 120L N 63 45 in 1612 mm 8 44 in ...

Page 7: ...duce the heights of these models TMB2334N A B C D W H F Y X V TOP VIEW OF EXHAUST DUCT E G I Cabinet Dimensions Models A B C D E F G H I 170L N S 33 86 in 860 mm 32 5 in 826 mm 50 75 in 1289 mm 51 75 in 1314 mm 68 85 in 1749 mm 52 12 in 1324 mm 53 12 in 1349 mm 94 in 2388 mm 75 12 in 1908 mm Exhaust Outlet Dimensions and Locations Models V W X Y 170L N S 42 38 in 1076 mm 6 75 in 171 mm 6 in 152 mm...

Page 8: ...D B D 120L N 170L N Models Electrical Connection Gas Connection A B C D Diameter Non CE 120L N 27 63 in 702 mm 72 24 in 1835 mm 12 78 in 325 mm 70 12 in 1781 mm 3 4 in NPT 170L N 31 12 in 790 mm 76 11 in 1933 mm 14 5 in 368 mm 77 38 in 1965 mm 1 in NPT CE 120L N 19 69 in 500 mm 74 98 in 1904 mm 12 78 in 325 mm 70 12 in 1781 mm 3 4 in NPT 170L N 23 18 in 589 mm 78 85 in 2003 mm 14 5 in 368 mm 77 38...

Page 9: ...5 in 911 mm 13 375 in 340 mm 82 75 in 2102 mm 170S 3 4 in NPT 37 625 in 956 mm 15 25 in 387 mm 88 in 2235 mm Models Steam Outlet Diameter B1 B2 D 120S 3 4 in NPT 34 625 in 879 mm 13 125 in 333 mm 68 5 in 1740 mm 170S 1 in NPT 44 625 in 1133 mm 8 75 in 222 mm 71 75 in 1822 mm Models Electrical Connection C E Non CE 120S 27 63 in 702 mm 72 24 in 1835 mm 170S 31 12 in 790 mm 76 11 in 1933 mm CE 120S ...

Page 10: ...possible and check the items listed on the packing list Advise the carrier of any damaged or missing articles as soon as possible A written claim should be filed with the carrier immediately if articles are damaged or missing IMPORTANT Warranty is void unless tumbler is installed according to instructions in this manual Installation should comply with minimum specifications and requirements detail...

Page 11: ...ece may be used to conceal the opening zero clearance allowed for trim 3 4 in 102 mm maximum header thickness 4 Minimum clearance permitted for remainder Gas 4 in 102 mm Steam 12 in 305 mm 5 Guard 6 Provision for Make Up Air 7 24 in 610 mm minimum 36 in 914 mm recommended for maintenance purposes 8 0 25 in 6 mm recommended for removal or installation purposes zero clearance allowed TMB2020N 4 1 5 ...

Page 12: ...nd may void machine warranty For maximum efficiency and minimum lint accumulation tumbler air must be exhausted to the outdoors by the shortest possible route Proper sized exhaust ducts are essential for proper operation All elbows should be sweep type Exhaust ducts must be assembled so the interior surfaces are smooth so the joints do not permit the accumulation of lint DO NOT use plastic or thin...

Page 13: ...TE Static back pressure must be measured with the tumbler running The maximum allowable length venting of the same diameter as the exhaust thimble is 14 feet 4 3 m and two 90 elbows or equivalent If the equivalent length of a duct required for an installation exceeds the maximum allowable equivalent length the diameter of a round duct must be increased by 10 for each additional 20 feet 6 1 m Cross...

Page 14: ...st be sized per local codes NOTE Inside of duct must be smooth Do not use sheet metal screws to join sections Consult your local building code for regulations which may also apply TMB2103N 1 Removable strip of panel in framing wall to permit removal of tumbler from framing wall 2 Partition or bulkhead 3 Minimum distance between exhaust opening and roof ground or other obstruction 36 in 914 mm 4 2 ...

Page 15: ...is not reduced Provisions MUST be made for lint removal and cleaning of the collector duct The vent collector system must be designed so the static back pressure measured 12 inches 305 mm from the exhaust outlet does not exceed the maximum allowable pressure specified on the installation sticker on the rear of tumbler Static back pressure must be measured with all tumblers vented into the collecto...

Page 16: ...K J I H G F E D C B A 3 1 2 ONE MANIFOLD ASSEMBLY Duct Station 120 Pound 170 Pound 10 in 254 mm Duct 12 in 305 mm Duct A 10 in 254 mm 12 in 305 mm B 15 in 381 mm 17 in 432 mm C 18 in 457 mm 21 in 533 mm D 21 in 533 mm 24 in 610 mm E 24 in 610 mm 27 in 686 mm F 26 in 660 mm 30 in 762 mm G 28 in 711 mm 32 in 813 mm H 30 in 762 mm 34 in 864 mm I 32 in 813 mm 36 in 914 mm J 33 in 838 mm 38 in 965 mm K...

Page 17: ...L K J I CONTINUE TO A CONTINUE TO A TWO MANIFOLD ASSEMBLIES Duct Station 120 Pound 170 Pound 10 in 254 mm Duct 12 in 305 mm Duct A 15 in 381 mm 17 in 432 mm B 21 in 533 mm 24 in 610 mm C 26 in 660 mm 30 in 762 mm D 30 in 762 mm 34 in 864 mm E 33 in 838 mm 38 in 965 mm F 36 in 914 mm 42 in 1067 mm G 39 in 991 mm 45 in 1143 mm H 42 in 1067 mm 45 in 1143 mm I 45 in 1143 mm 52 in 1321 mm J 47 in 1194 ...

Page 18: ...k Connections Required Rated Current Breaker Rating Breaker Poles Recommended Wire Size 208 230V 60Hz 3ph L1 L2 L3 and ground 7 7 15 Amps 3 14 AWG 2 08 mm2 380 415V 50Hz 3ph L1 L2 L3 and ground 3 8 10 Amps 3 14 AWG 2 08 mm2 380V 60Hz 3ph L1 L2 L3 and ground 4 1 10 Amps 3 14 AWG 2 08 mm2 440V 60Hz 3ph L1 L2 L3 and ground 3 8 10 Amps 3 14 AWG 2 08 mm2 460 480V 60Hz 3ph L1 L2 L3 and ground 3 9 10 Amp...

Reviews: