Basic info about Blood Pressure
Systolic pressure means that the ventricles contract and pump out
blood, increasing the blood pressure. The diastolic pressure means
that the ventricles relax so the blood pressure decreases.
AHA indicator
After each measurement an arrow indicates the corresponding
category color on the left of the display. The colors represent the
different categories of the American Heart Association blood
pressure classification as depicted in the chart below.
Changes in blood pressure
There are many factors that cause the blood pressure to change.
Weather, emotions, stress, food, physical activities; all these
influence the variations in the blood pressure. Bear in mind that
measuring in clinical settings tend to cause the blood pressure to
increase. This is called “white coat effect”.
Error Messages and FAQ
Important Symbols on the Monitor
Complied European Standards List
Normal
less than 120
less than 80
100 or higher
Higher than 100
Higher than 180
80-89
120-139
Prehypertension
High Blood Pressure
(hypertension) Stage 1
High Blood Pressure
(hypertension) Stage 2
Hypertensive Crisis
(Emergency care needed)
140-159
160 or higher
90-99
and
or
or
or
or
Blood Pressure
Category
Systolic
mm HG (upper#)
Diastolic
mm Hg (lower#)
Power supply
Display mode
Digital LCD V.A.36mmx41mm
Measurement mode
Oscillographic testing mode
Measurement range
Accuracy
Normal working condition
Storage & transportation
condition
Measurement perimeter
of the wrist
About 13.5cm-21.5cm
Net Weight
Approx.120g(Excluding the dry cells)
External dimensions
Attachment
Mode of operation
Continuous operation
Degree of protection
Type BF applied part
Protection against
ingress of water
Software version
Device classification
Internally Powered ME Equipment
Temperature:-20
℃
to 60
℃
Relative Humidity: 10% RH to 93% RH
Temperature:5
℃
-40
℃
Relative humidity: ≤85%RH
Atmospheric pressure: 86kPa to 106kPa
Pressure:
5
℃
-40
℃
within±3mmHg(0.4kPa)
Pulse value:±5%
Rated cuff pressure:
0mmHg~300mmHg (0kPa - 40kPa)
Measurement pressure: 40mmHg-230mmHg
(5.3kPa-30.7kPa)
Pulse value: (40-199) beat/minute
Symbol for “THE OPERATION
GUIDE MUST BE READ”
Symbol for “TYPE BF APPLIED
PARTS”
Symbol for “DIRECT CURRENT”
Symbol for “ENVIRONMENT
PROTECTION - Electrical waste products
should not be disposed of with
household waste. Please recycle where
facilities exist. Check with your local
authority or retailer for recycling advice”
Symbol for “MANUFACTURE
DATE”
Caution: These notes must be
observed to prevent any damage
to the device.
Electromagnetic Compatibility Measures
Please pay attention to the precautions of EMC (Electromagnetic
Compatibility) of this Monitor. The Blood Pressure Monitor must
be installed and used according to the EMC information shown in
this manual. The device can be affected by portable and mobile RF
communication equipment.
Remove any devices that emit electromagnetic fields such as
mobile phones from nearby the device.
The Blood Pressure Monitor has been tested and inspected to
guarantee a proper performance.
Do not store or use this Monitor with other electric equipment.
Manufacturer’s declaration on Electromagnetic Emissions for all ME
Equipments and Sytem
Manufacturer’s declaration on Electromagnetic
Immunity for all ME Equipments and Systems
Manufacturer’s declaration on Electromagnetic
Immunity for all ME Equipments and Systems
that do not provide LIFE-SUPPORTING
The safe distances between portable and mobile
RF communications equipment, ME Equipments
and Systems that are not LIFE-SUPPORTING
Warranty
This Limited Warranty covers any defects in materials or work-
manship under normal use during the Warranty Period. iProvèn
will either replace the product or repair the product at no charge,
using new or refurbished replacement parts. The Warranty Period
of this iProvèn product is 2 years from the date of purchase. A
replacement product or product part assumes the remaining
warranty of the original product purchase. This Limited Warranty
does not cover batteries and packaging, nor any problem that is
caused by conditions, malfunctions, or damage not resulting from
defects in material or workmanship.
To obtain warranty service, contact our customer support at
www.iproven.com to determine the problem and the most
appropriate solution for your situation.
iProvèn owns and reserves the rights comprised in the copyright of
this document. No part of this document may be changed, copied,
reproduced, or imitated in any form or by any means without
prior written consent of iProvèn. All statements, information, and
recommendations in this document are provided “AS IS” without
warranties, guarantees or representations of any kind, either
express or implied. The information in this document is subject to
change without notice. iProvèn reserves the right of final interpre-
tation of this document.
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
HEADQUARTERS
Ebweg 12D
2991 LT Barendrecht
The Netherlands
Phone: +31 (0)84-8838876
DISTRIBUTED BY
NETDIRECT DISTRIBUTION, LLC
9360 Federal Blvd
Denver , CO 80260
Phone: 1-503-974-0913
ISO 15223-1:2012
IEC 62304:2006
IEC 62366:2007
IEC60601-1-6:2010
ISO 81060-2:2009
Atmospheric pressure: 50PA to 106kPa
ISO 14971:2007
IEC 60601-1:2005
IEC 60601-1-2: 2007
Symbol for Serial Number
IEC 60601-1-11:2010
IEC80601-2-30: 2009
Particular requirements for the basic safety and
essential performance of automated noninvasive
sphygmomanometers