Do Not Overload Generator
Overloading a generator in excess of its rated wattage
capacity can result in damage to the generator and to
connected electrical devices.
To prolong the life of your generator and attached
devices, follow these steps to add electrical load:
Low Oil Shutdown
If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with
dipstick.
If oil level is between LOW and HIGH mark on
dipstick:
1.
DO NOT
try to restart the engine.
2. Contact an Authorized Service Dealer.
3.
DO NOT
operate engine until oil level is corrected.
If oil level is below LOW mark on dipstick:
1. Add oil to bring level to HIGH mark.
2. Restart engine and if the engine stops again a low
oil condition may still exist.
DO NOT
try to restart
the engine.
3. Contact Customer Service.
4.
DO NOT
operate engine until oil level is corrected.
DANGER
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Fire or explosion can cause severe burns or death.
NOTE:
DO NOT
stop the engine by moving choke control to
“START”
position.
Always ensure that the gasoline valve is on the
“OFF”
position and propane/LPG cylinder fully closed when
the engine is not in use. If the engine will not be used
for a period of two weeks or longer, please see the
Storage section for proper engine and fuel storage.
• Turn the propane/LPG cylinder knob to close
position.
1. Start the generator with no electrical load attached.
2. Allow the engine to run for several minutes to
stabilize.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
Changing Fuels
DANGER
Gasoline, gasoline vapor and propane/LPG are highly
flammable and explosive.
Fire or explosion can cause severe burns or death.
DANGER
2. Flip the engine switch to
“STOP”
position. Do
not leave the generator until it has completely
stopped.
3.Close the fuel sources.
•Turn the gasoline valve to
“OFF” (0)
position.
OFF
Summary of Contents for SUA12000ED
Page 38: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 40: ...Fontana CA 92337 USA Phone 1 855 888 3598 support a ipower com www a ipower com ...
Page 80: ......
Page 81: ......
Page 82: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 84: ...Fontana CA 92337 EE UU Teléfono 1 855 888 3598 support a ipower com www a ipower com ...
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...
Page 128: ...Fontana CA 92337 USA Téléphone 1 855 888 3598 support a ipower com www a ipower com ...