ipf electronic OV630840 Operating Instructions Download Page 2

H1   H2     

S7

S1 - S3

OUTPUT-
STATUS

OUTPUT-
STATUS

GAIN-
CONTROL

GAIN-
CONTROL

ALARM

ON

TEST/RESET

high

high

manual

manual

low

low

automatic

automatic

dark

dark

light

light

MANUAL

GAIN

MANUAL

GAIN

SENSOR
ERROR

SENSOR
ERROR

AMPLIFIER MODE

IT

IT

IR

IR

CHANNEL 1

CHANNEL 2

C

h

a

n

n

e

l1

C

h

a

n

n

e

l2

2-CHANNEL

INFRARED-AMPLIFIER

S4 - S6

H3   H4     
H5   H6     

P1   P2  

H7 - H8     

CH 1

CH 2

Anzeigen und Bedienelemente

H1 - H2:   Schaltzustand / Senderfehler-Anzeige

 - gelb

H3 - H4:   Empfindlichkeit / Empfängerfehler-Anzeige

 - grün

H5 - H6:   Sensor-Fehler

 - rot

H7:   

 Alarmanzeige

 - rot

H8:   

 Betriebsanzeige

 - grün

P1-P2:   Empfindlichkeitseinsteller für Manuell-Betrieb

S1 - S3:   DIP-Schalter Kanal 1

S4 - S6:   DIP-Schalter Kanal 2

S7:   

 Test / Reset-Taster

Display content and operating elements

H1 - H2:   Switching indicator / Transmitter error 

- yellow

H3 - H4:   Sensitivity display / Receiver error

 - green

H5 - H6:   Sensor Error display

 - red

H7:   

 Alarm display

 - red

H8:   

 Power On display

 - green

P1 - P2:   Manual Gain control

S1 - S3:   DIP-switch channel 1

S4 - S6:   DIP-switch channel 2

S7:   

 Test / Reset-Taster 

Inbetriebnahme

Vor Inbetriebnahme DIP-Schalter S1 - S3 (S4 - S6) am Gerät passend einstellen. Sen-

soren aufeinander ausrichten. Nach Anlegen der Betriebsspannung und automatischem 

Reset, stellt sich in der Betriebsart 

Automatik

 die Sendeleistung selbstständig ein. Bei 

fehlerfreiem Betrieb leuchtet H3 (H4) auf (Automatik aktiv). Gleichzeitig  leuchtet in Hell-

schaltung H1 (H2). In der Betriebsart 

Manuell

 muss der Anwender die Sendeleistung mit 

P1 (P2) auf die erforderliche Höhe bringen, sodass bei Sichtverbindung H3 (H4) leuchtet. 

In Hellschaltung leuchtet auch hier gleichzeitig H1 (H2) (siehe 

Tabelle: Schaltlogik

).

- Alarm - mit Alarmausgang

Der Alarmzustand tritt ein, wenn die Sendeleistung im Manuell-Betrieb nicht ausreichend 

ist, oder im Automatik-Betrieb der Prozessor nicht mehr nachregeln kann. Ursache 

ist z. B. eine Verschlechterung der Sicht, eine zu große Distanz oder Dejustage der 

Sensoren. Nach Beseitigung des Fehlers erlischt die Anzeige.

Testeingang

Legt man an den Testeingang 24 V DC an, so schaltet der Sender ab. Damit kann die 

Funktion der Lichtschranke überprüft werden.

- Test -

Durch kurzes Drücken von S7 - Funktion Test - wird erst die Streckenqualität von Kanal 

1 durch Blinken von H3 (1x - schlecht bis 10x - sehr gut) angezeigt. Ist keine Sichtver-

bindung vorhanden, blinkt lediglich H5. Danach folgt das Ergebnis von Kanal 2 mit H4. 

Ist hier keine Sichtverbindung vorhanden, blinkt lediglich H6.

- Reset -

Nach Anlegen der Betriebsspannung oder langes Drücken von S7, führt das Gerät 

einen Reset durch. Der Reset beinhaltet einen Lampentest. Alle Anzeigen erlischen  

und leuchten danach kurz auf. Zusätzlich findet im Automatik-Betrieb eine automatische 

Neuregelung der Sendeleistung vom Maximalwert auf den Sollwert statt.

- Sensor Error - mit Errorausgang

Mit der Sensor Error-Funktion überwacht das Gerät den elektrischen Zustand der Sen-

soren auf Kurzschluss und Unterbrechung. Tritt ein Fehler auf, so meldet dies das Gerät 

durch die Anzeigeelemente. Schnelles Blinken bedeutet Kurzschluss und langsames 

Blinken bedeutet Unterbrechung (siehe Tabelle 

Logik Sensor Error

).

Operating procedure

Before operating procedure you have to choose the DIP switch setting S1 - S3 (S4-S6) 

for your application. Sensor heads adjusts one on top of the other. After switch on the 

power supply and automatic reset, the transmit power will be turned to the optimum 

(Automatic mode). When there is no error LED H3 (H4) lights (automatic active) and 

H1(H2) lights (in light switching mode). In the Manual mode you have to adjust the 

transmit power with P1 (P2) until H3 (H4) signals sufficient power. In light switching 

mode H1 (H2) lights too (See also 

table: Switching logic

).

- Alarm - with Alarm output

Alarm is active, when the transmit power is not sufficient in the Manual mode or the 

automatic adjustment is interrupted. The cause can be e. g. deterioration of the beam, 

too large distance or misadjustment of sensor heads. Is the cause removed, the alarm 

is no longer active.

Test input

With a voltage about 24 V DC at the test input, the transmitter beam switches off. With 

this feature you can test the system.

- Test -

Short-time pressing of button S7 results flashes between 1 and 10 times of H3 to signal 

the received power of channel 1. They are proportional to the received signal. If there 

is no received signal, only H5 flashes up. After that the same procedure starts with ch 

2. Here H4 signals the quality and if there is no signal, only H6 flashes up. 

- Reset -

After connecting the device with power supply or pressing of button S7 for longer time, 

a Reset will done. This means a test of all displays. All LEDs lights down and up for 

a short time. Additionally in Automatic mode a new adjustment of the transmit power 

starts from maximum to the nominal value.

- Sensor Error - with error output

This function controls the electrical state of the sensor heads. If there is an error (short-

circuit or too high resistance resp. disconnection) H5 (H6) lights up. Additionally H1(H2) 

(= transmitter error) or / and H3 (H4) (= receiver error) flashes slowly (= high resistance) 

or fast (= short-circuit). See for this table 

Logic Sensor Error

.

Logik Sensor Error | Logic Sensor Error

89,6

95

58

Maßzeichnungen

 

in mm |

 

Dimensions

 

in mm

Technische Daten

 (bei 20 °C U

b

= 24 V DC)

OV630840

Technical data

 (at 20 °C (68 °F), V

s

= 24 V DC)

Betriebsspannung

24 V DC / ± 20% / 3,6 W

Supply power

Messverfahren

moduliertes OE-Licht

modulated OE-light

Operating basis

max. Reichweite (Einweg)

Max. range (Through beam)

Sender

Empfänger / Receiver 

OE 12 63...

Empfänger / Receiver 

OE 10 60 ..., 12 60 ..., 13 60 ...

     Transmitter

OS 10 60 ..., 12 60 01, 12 60 03, 12 60 20, 13 60 ...

8 m (26 ft)

20 m (66 ft)

     OS 10 60 ..., 12 60 01, 12 60 03, 12 60 20, 13 60 ...

OS 12 60 08, 12 60 26

10 m (33 ft)

30 m (99 ft)

     OS 12 60 08, 12 60 26

OS 10 61 ..., 12 63 ...

20 m (66 ft)

55 m (182 ft)

     OS 10 61 ..., 12 63 ...

Sendefrequenz

3,9 kHz

Transmit frequency

Multiplexgeschwindigkeit

8 ms

Multiplex speed

Sendeleistung

manuell / automatisch

manual / automatic

Transmit power

Schaltfunktion bzw. Schaltverhalten

hell / dunkel

light / dark

Switching behavior

Grundleistung

high / low

System power manual mode

Schaltverzögerung / Impulsbreite

Switching delay / impulse period

Schaltausgang (kurzschlussfest)

Schließer (Halbleiter-Relais)

NO (Semiconductor-Relay)

Switching output (short-circuit proof)

max. Schaltwerte

100 mA / 60 V AC (DC)

values (max.)

Reaktionszeit

24 ms

reaction time

Alarm-/Errorausgang (kurzschlussfest)

pnp: 100 mA / 24 V DC

Alarm / Error output (short-circuit proof)

Analogausgang

Analog output

Testeingang

Activ HIGH (L= 0...5 V DC, H= 15...30 V DC)

Test input

Gehäusewerkstoff

NORYL RAL 7035 (grau / grey)

Housing material

Schutzart

IP 20

Protection class

Anschluss-Querschnitt

0,14 - 2,5 mm²

Terminal size

Betriebstemperatur

-25 °C...+50 °C (-13 °F...+122 °F)

Operating temperature

Gehäuseabmessungen

siehe Maßzeichnung

see dimensions

Housing measurements

BEDIENUNGSANLEITUNG • Änderungen vorbehalten! Stand: 

Juli 2022

ipf electronic gmbh • Rosmarter Allee 14 • 58762 Altena 

 Tel +49 2351 9365-0 • Fax +49 2351 9365-19 

 [email protected] • www.ipf.de 

2

 

Reviews: