ipf electronic OT059176 Manual Download Page 2

 

 

 

MANUAL • Subject to alteration! Version: July 2019 

 

 

ipf electronic gmbh

 • Rosmarter Allee 14 • 58762 Altena 

 Tel +49 2351 9365-0 • Fax +49 2351 9365-19 

 [email protected] • www.ipf-electronic.com    

2

 

 

 
Installation and environment 

Two nuts are included to attach the device. 
The maximum tightening torque of 1Nm must not be exceeded! 

Coverings on the optics impair the function. Please install the device in such a way that dust cannot be deposited or 
liquids can get on the optics. The device should be accessible for cleaning. 
From time to time, the optics should be cleaned with a soft cloth moistened with soapy water.

 

 
 

Cable 

The connecting cable between sensor and M8-connector should be laid as fixed as possible or strain-relieved. 

 
 

Adjustment 

Mount the device by taking into account the sensing range, so that the object is reliably detected. In case of reliable 
detection, the LED lights up green. 
If the LED lights up yellow, the device is in an insecure area. The cause may be an object that is too far away or even 
soiling. 
There should be no other objects than the one to be detected within the detection area or its border.

 

The sensing range is adjustable between 30 and 100mm (90% reflectivity) by a teach-in-procedure.  

1.

 

Install the sensor at the required position and bring the object to be detected into the beam path within the 
specified operating range. 

2.

 

Connect the white wire (PIN 2) to the operating voltage (brown wire, PIN 1). 

3.

 

As soon as the LED starts to flash yellow, disconnect the connection. 

4.

 

The desired sensing range is set. 

5.

 

If the distance to the object is more than 100mm, the maximum operating range is automatically set. 

 

 
 

Note 

The devices respond to the intensity of the light that is reflected of any object. The nominal switching distances are 
based on white paper with an area of 100 x 100mm. The possible detection ranges for less reflective materials can be 
found  in  the  table  "sensing  range".  The  switching  distance  increases  with  more  reflective  materials  (e.g.  polished 
aluminum).

 

 
 

 

Sensing range 

    Light spot size 

target (reflectivity) 

operating range 

sensing range max. 

white (90%) 

0 … 100mm 

0 … 120mm 

grey (18%) 

0.1 … 50mm 

0.1 … 60mm 

black (6%) 

0.2 … 30mm 

0.2 … 35mm 

 
 
SAFETY WARNINGS: 
 

Before initial operation, please make sure to follow all safety instructions that may be provided in the product 
information! 

Never use these articles in applications where the safety of a person depends on their functionality. 

Reviews: