ipf electronic opti-check OC5396 Series Quick Start Manual Download Page 2

Creating a job in 4 steps

Overview feature checks

Commissioning of Ethernet interface

Part location

Part location  

on contours

Part location  

on edges

Part location  

on circle

Part location  

on text line

Geometry

Distance

Circle

Angle

Count edges

Point position

Feature comparison

Count  

contour points

Contour 

comparison

Brightness

Contraste

Area size

Count areas

Pattern 

comparison

Identification

Barcode

Matrix code

Text

To use 

opti-check

 in your network, you must assign the device a unique IP address. 

The default factory configuration is:
1.  If your network has an DHCP server, the IP address will request from that server.  
 

You do not need any further manual adjustments.

2.  If a valid IP address can not be determined within 15 seconds, the following  
 

network configuration is used: 

 

Default IP address: 

192.168.0.250

 (Subnet mask: 

255.255.255.0

)

My device is not located in the selection list after launching the 
Application Suite?

1.  Check that the power cable of 

opti-check

 is connected correctly.

2.  Make sure that your PC and 

opti-check

 are connected in the same network.

3.  Check the network settings of your PC, especially the IP address and subnet  
 

mask. Contact your administor possibly.

4.  Make sure that each IP address is unique in your network!

Choose your device in the selection list. With 

CONNECT

 

button, you connect with the selected 

opti-check

 vision 

sensor.

Launch of 

opti-check

 

Application Suite

To implement reliable inspection with the 

opti-check

 

vision sensor, the features to be inspected must be clearly 
visible.
Set the 

image focus

 with an inbus key on the 

opti-

check

 vision sensor installed at the testing site. The 

corresponding inbus screw can be found on the sensor’s 
LED panel.
Set the trigger to 

CONTINuOuS IMAGE CAPTuRE

Use the option 

Automatically generate suggestion…

 

Enter the 

speed

 of the object and the 

distance

 to object 

between the sensor and the object (see front page, 
Mechanical setup). The 

Application Suite calculates the 

corresponding parameters automatically.
Manual fine adjustments of 

image brightness 

can be 

made with the slider bar 

EXPOSURE TIME

. Adjust the image 

so that the object is seen to be bright enough without the 
need to override.

1.  Adjusting an optimum image

Now you can determine which features of the object to 
be checked.
The command to link new feature checks is located in the 
right hand corner of the 

parameter area

. With the 

ADD

 

button, you can create a new feature check for your job.
As each inspection process has 

tolerances with regard 

to the position

 of the test object, most jobs begin with 

part location

. The part location searches for the reference 

edges of the test object and aligns all subsequent feature 
checks to these reference edges.
After selection of a feature check you can parametrize the 
feature to be checked. Each feature is optimized for just 
one inspection task and supplies a 

Pass (OK)

 or  

Fail (NOK)

 result.

2.  Add new feature checks

You can now activate 

opti-check

.  

The 

Application Suite displays the current statistics of 

each feature check, the entire evaluation and live images

4. Activate 

opti-check

 

3.  Configure interfaces

Example:  
Setting of feature check 

BRIGhTNESS

For this example, select the feature check 

BRIGHTNESS

 on 

the tab 

FEATURE COMPARISON

. Confirm selection of this 

feature check with OK. 
 
 
 
In the example, the 

working area

 is dragged as a circle. 

Adjust it by clicking on area’s center and holding the left 
mouse button depressed. 
 
 

The mean gray-value currently measured in the working 
area is indicated as 

BRIGHTNESS

The associated switching thresholds for Pass/Fail may be 
adjusted by graphic input or by directly entering the  

MIN 

/

 MAX

 values. 

 
Confirm your settings with the 

OK

 button.

The description of feature checks in detail is found in the 
information window of the 

Application Suite and in the 

technical documentation.

2.  Add new feature checks

NOTE

For OC539620-OC539622 and 
OC539720-OC539722, the image 
focus is set on the installed lens.

Select the appropriate settings on the tabs.

Output assignment, Flexible result conjunction  

(OC5394XX / OC5395XX / OC5396XX / OC5397XX only)

Output time, Duration of output signal

Settings, as the data is transferred 

(excluding OC5391XX)

Inputs about the process interface 

(excluding OC5391XX)

Configuration web interface

Reviews: