IPEX
(IP Electronix)
PH485iX
:
User’s Manual
Page 7 of 12
Doc No. : PH485iX-UM-001
21 August 2019
6.
Device Settings
RS-422
To use PH485iX as a RS-232 to RS-422 converter, it is not required to set a Baud-Rate and DIP-Switch condition
(on the Top Panel), is not important.
RS-485
Before using PH485iX as a RS-232 to RS-485 converter, it is necessary to set the DIP-Switch (on the top Panel) to
proper condition according to desired Parity, Baud-Rate and . PH485iX supports a wide range Baud-Rates from
1200 bps to 921600 bps.
Set the DIP-Switch condition according to the following table to set the suitable Baud-Rate.
6.1)
Parity
Set the Parity type by the DIP-Switch keys number 1 and number 2 on the device. “None”, “Even” and “Odd”
Parity type are supported by PH485iX. The Parity setting are shown in the following table.
6.2)
Noisy Environment
In the noisy environments, set the key number 3 ON (up state), otherwise set it OFF (down state)
6.3)
Data-Length
7-Bits and 8-Bits Data-Length are supported by PH485iX. Set Data-Length by key number 4.