10.

 

Network Connection Testing 

Connect PH232Ex1 to the Ethernet based network by connecting RJ45 LAN socket to network via a switch or 
Hub by an ordinary CAT5 or CAT6 cable. If everything is set properly, the green and yellow LEDs on the 
PH231Ex2’s RJ45 socket will blink. 

Now it is important to check the network wiring topology, and testing all the cables, routers, switches … in the 
route from PH232Ex1 to the computer. This test is done simply by using PING command from computer. 

Go to Windows command prompt, (press WINDOWS KEY + R to going to run dialog and then type CMD and 
press enter): 

 

 

Type ping with the device IP address, for example “ping 192.168.0.2”and press Enter. 

Now you should see the ping response from the device.  

Summary of Contents for PH232Ex1 Series

Page 1: ...Doc No PH232Ex1 UM 001 USER S MANUAL IPEX IP Electronix 14 January 2014 PH232Ex1 1 RS 232 Serial Port to Ethernet Terminal Server Client...

Page 2: ...4 TOP PANEL 4 5 FRONT PANEL 5 6 RS 232 SERIAL PORTS PIN CONFIGURATION PORT 1 PORT 2 5 7 RS 232 CONNECTING METHODS 6 8 CONNECTION DIAGRAM 9 9 DEVICE NETWORK AND SERIAL PORT SETTINGS 11 10 NETWORK CONN...

Page 3: ...solation between Ethernet and RS 232 sides in i model PH232Ex1 comes complete with drivers for Microsoft Windows XP CE 2003 2008 7 Its setup file creates a virtual COM Port on your Server PC or Laptop...

Page 4: ...eneral Indicators POWER LED Green It is turned ON when the power supply connects to VDC and GND correctly SERVER LED Green It is turned ON if the device is in Server Mode CLIENT LED Green It is turned...

Page 5: ...www ipelectronix com IPEX IP Electronix PH232Ex1 User s Manual Page 5 of 23 Doc No PH232Ex1 UM 001 14 January 2014 5 Front Panel 6 RS 232 Serial Ports Pin Configuration PORT 1 PORT 2...

Page 6: ...es Modem or other DCE devices DB9 Female Pin Number PH232Ex1 Port 1 as DTE DB9 Male Pin Number Pin 1 DCD Output Pin 1 DCD Input Pin 2 RxD Output Pin 2 RxD Input Pin 3 TxD Input Pin 3 TxD Output Pin 4...

Page 7: ...other DTE devices DB9 Male Pin Number PH232Ex1 Port 1 as DTE DB9 Male Pin Number Pin 7 RTS Output Pin 1 DCD Input Pin 3 TxD Output Pin 2 RxD Input Pin 2 RxD Input Pin 3 TxD Output Pin 6 DSR Input Pin...

Page 8: ...7 3 Simple Null Modem Connection to PC PLC Without Hardware Handshaking PC PLC or other DTE devices DB9 Male Pin Number PH232Ex1 Port 1 as DTE DB9 Male Pin Number Pin 3 TxD Output Pin 2 RxD Input Pin...

Page 9: ...tion software you want There are two methods in order to be connected to the PH232Ex1 COM Ports via Ethernet As the first way it is possible to connect to the device by opening a normal COM Port if yo...

Page 10: ...RS 232 Ports to each other via Ethernet network you can use this connecting method Take two PH232Ex1 Set one PH232Ex1 as Server and another one as Client with adding Remote Server IP on it These two c...

Page 11: ...connectors on the both ends which connect at least pins 2 to 3 3 to 2 and 5 to 5 of both sides Now run a terminal emulator on your computer You can find some terminal emulators in the Utility folder i...

Page 12: ...on the Hyper Terminal Entering Device Network and Serial Ports Setting Menu IMPORTANT Now to enter device network and serial ports settings menu follow the below procedure step by step 1 Push the CONF...

Page 13: ...lt settings in this page It is possible to change the entire network and serial ports settings from this menu For example if you want to change the IP Address of the device first press 1 enter new IP...

Page 14: ...ly the green and yellow LEDs on the PH231Ex2 s RJ45 socket will blink Now it is important to check the network wiring topology and testing all the cables routers switches in the route from PH232Ex1 to...

Page 15: ...23 Doc No PH232Ex1 UM 001 14 January 2014 If there are any problems in the network you could not see response from the device If you see this timeout window you can t continue installation and first...

Page 16: ...port numbers is as follow Port 1 9761 Port 2 9762 only in PH232Ex2 For example we connect to Port 1 by means of Hyper Terminal Run Hyperterm exe and from properties dialog box select TCP IP Winsock En...

Page 17: ...he second method for connecting to PH232Ex1 serial ports is to install virtual COM port driver on your computer and open ports as a normal Windows COM port Run PHEx2_32bit exe if your Windows is 32 bi...

Page 18: ...www ipelectronix com IPEX IP Electronix PH232Ex1 User s Manual Page 18 of 23 Doc No PH232Ex1 UM 001 14 January 2014 In this dialog box click on Next Now click on Install...

Page 19: ...ny running application on your system and then from Windows Start Programs IPEX run PHEX2 exe Simply Enter PH232Ex1 IP Address and serial port number for Port 1 and then press apply For example type 4...

Page 20: ...1 User s Manual Page 20 of 23 Doc No PH232Ex1 UM 001 14 January 2014 If during installation you see this Window Select Install the software automatically Recommended and click on Next Now click on Fin...

Page 21: ...NOTICE If COM Port number you select is previously used by other application you cannot choose that port number for the device To see which COM Port is in use by the system run Device Manager and from...

Page 22: ...EX IP Electronix PH232Ex1 User s Manual Page 22 of 23 Doc No PH232Ex1 UM 001 14 January 2014 Now you can see which COM port is free and which COM port is in use You must select COM port number for you...

Page 23: ...arantee All products manufactured by IPEX are under warranty regarding defective materials for a period of one year from the date of delivery to the original purchaser 15 Technical Support If you have...

Reviews: