background image

 

Walter-Bouhon-Strasse 4 
90427 Nuremberg 
Germany 

Edition June 2021 

Version 1.4 

Phone: 
Fax: 
Internet: 
E-mail: 

+49 911 18 07 91-0 
+49 911 18 07 91-10 

https://www.ipcomm.de

 

[email protected] 

 

 

SEC3x 

Small Embedded Controller

 

 

General Operating, Maintenance, 

 

 

and Installation Manual 

 

 

 

 

Summary of Contents for SEC3 Series

Page 1: ...uremberg Germany Edition June 2021 Version 1 4 Phone Fax Internet E mail 49 911 18 07 91 0 49 911 18 07 91 10 https www ipcomm de info ipcomm de SEC3x Small Embedded Controller General Operating Maint...

Page 2: ...ainboard 9 2 4 2 RS 232 RS 422 RS 485 Interfaces 9 2 4 3 Network Interfaces 9 2 4 4 PROFIBUS 10 2 4 5 I O Interfaces 11 2 4 6 Mobile Network Interfaces 12 2 4 7 Flash Mass Storage 12 2 4 8 Lithium Bat...

Page 3: ...on of your data and equipment against external influences We will be pleased to draw up a non binding offer for you Finally we want to draw your attention to the fact that any warranties with respect...

Page 4: ...n all interfaces min 48 hours Communication disruptions transmission errors and every important component with regard to function temperature voltages etc are monitored Hundreds of restarts are execut...

Page 5: ...ights reserved Germany 2 3 Controls and Display Elements 2 3 1 SEC3 SEC3 SA Figure 1 SEC3 front view Figure 2 SEC3 rear view Diagnostic LEDs CPU User Power COM2 port COM1 port Power supply connection...

Page 6: ...rved Germany 2 3 2 SEC3PB Figure 3 SEC3PB front view Figure 4 SEC3PB rear view PROFIBUS Diagnostic LEDs Receive Power Operation Diagnostic LEDs CPU User Power COM1 port ETH0 port ETH1 port PROFIBUS US...

Page 7: ...SEC3IO SA Figure 5 SEC3IO front view Figure 6 SEC3IO rear view Diagnostic LEDs 8x digital input 8x digital output Diagnostic LEDs CPU User Power COM1 port ETH0 port ETH1 port Connector strip for digit...

Page 8: ...ts reserved Germany 2 3 4 SEC3M Figure 7 SEC3M front view Figure 8 SEC3M rear view Diagnostic LEDs CPU User Power COM1 COM2 port ETH0 Eth1 port SIM card slot Mobile radio diagnostic LED Power supply c...

Page 9: ...be configured as a RS 232 RS 422 RS 485 interface by the software SERIAL PORT RJ45 female connector Pin RS 232 RS 422 RS 485 1 DSR 2 RTS TXD Data 3 GND GND GND 4 TXD TXD Data 5 RXD RXD 6 DCD RXD 7 CTS...

Page 10: ...edded controller offers a purely passive PROFIBUS DP interface The injection of data into the PROFIBUS is physically prevented PROFIBUS PORT DB9 female connector Pin Signal 1 2 3 BUS B D 4 5 GND 6 5 V...

Page 11: ...1 GND 2 DI 1 3 DI 2 4 DI 3 5 DI 4 6 DI 5 7 DI 6 8 DI 7 9 DI 8 Figure 13 Pin assignment digital inputs The digital outputs are also equipped with overvoltage protection and an additional overcurrent p...

Page 12: ...card not included in the scope of delivery SMA female antenna connector An LTE GSM antenna with flexible joint is used SMA male connector 08 mm x 95 mm D x H 2dBi 698 960 MHz 1710 2700 MHz 50 Ohm Opt...

Page 13: ...ame type 3 V DC CR2032 Used batteries are to be disposed in accordance with the manufacturer s instructions Contact IPCOMM GmbH to order a low priced spare battery CAUTION The device must be de energi...

Page 14: ...oltage Pin assignment power supply connection There are two voltage inputs for redundant feed in Voltage input 1 UPWR1 Pin 1 2 Voltage input 2 UPWR2 Pin 3 4 Figure 16 Power supply connection Each unit...

Page 15: ...play If the PWR LED is lit the module is supplied with voltage The USR LED is freely configurable An imaginable function would be to display a particular connection status or more than one as an overa...

Page 16: ...twork modem as follows STATUS LED ON LED OFF Setting up connection or Error 0 5s 0 5s No data channel OFFLINE 0 5s 5s Data channel established ONLINE 5s 0 5s 3 3 SEC3PB PROFIBUS Figure 20 PROFIBUS LED...

Page 17: ...Inputs Figure 21 LEDs for digital inputs When the input level high is reached the diagnostic LEDs DI 1 to DI 8 light up green 3 4 2 Digital Outputs Figure 22 LEDs for digital outputs If a digital outp...

Page 18: ...y to this document In addition to pure technical data the document also contains information on approval and applied standards EMC A current version of these can be found on our website under Hardware...

Page 19: ...ormity for the individual hardware models is available separately for this document A current version of these can be found on our website under Hardware SEC3x Documentation SEC3 SEC3 SA https www ipc...

Page 20: ...uration Power supply Value Description A 85 264 V AV E 9 60 V DC F 9 60 V DC EMV IEC 61850 3 RAM Flash Value Description A 256 MB 512 MB Flash Model Value Description A SEC3 The base model B SEC3PB Th...

Page 21: ...Subject to alterations Version 1 4 IPCOMM GmbH 21 SEC3x Manual Walter Bouhon Strasse 4 Copyright IPCOMM GmbH 2021 90427 Nuremberg All rights reserved Germany 7 SEC3x Dimensions 7 1 1 SEC3 7 1 2 SEC3PB...

Page 22: ...Subject to alterations Version 1 4 IPCOMM GmbH 22 SEC3x Manual Walter Bouhon Strasse 4 Copyright IPCOMM GmbH 2021 90427 Nuremberg All rights reserved Germany 7 1 3 SEC3IO 7 1 4 SEC3M...