35/42
Relay Output Setting
In relay output setting, the user can setup the output device to perform the
related output action.
I/O PIN definition, please refer to the following statement
ALARM
GND
ALARM INPUT
Standard Voltage: 3.3V (internal Voltage)
Connect “ALARM” and “GND” two pins.
N.C.
COM
N.O.
RELAY OUTPUT
Contact Rating: 30V DC/ 1A, 125V AC/ 0.3A
Depends on the devices, the user should connect “N.C.” and
“COM” pins or “N.O.” and “COM” pins
(1) Non-Triggered
(2) Triggered
Sensor
Device
ALARM
GND
3.3V
Sensor
Device
ALARM
GND
0V
3.3V
3.3V
Triggered