background image

INSTALLATION GUIDELINES

mOUNTING LOCATION

The IOTA Power Converter/Battery Charger can be mounted 
in any position within an enclosed or interior compartment. 
Provide sufficient air space to allow unrestricted airflow in and 
around the unit. Provide at least 4

 around the fan of the DLS 

to allow for proper air intake.
DO NOT mount the unit in a zero clearance compartment. 
DO NOT mount the DLS in the same compartment with 
flammable items such as gasoline or batteries. There are no 
components within the DLS unit that, during normal operation, 
produce arcs or sparks. However, all electronic devices have 
some potential for generating sparks in the event of failure 
which can result in explosion or fire.
DO NOT mount the DLS in an area that has the potential of 
dust, debris, or other foreign materials to enter in through the 
DLS vents. 
DO NOT place the DLS directly above the battery; the gases 
from the battery can corrode and damage the DLS.  

bATTERY CONNECTION

Before you connect the DLS to the battery, make sure that the 
AC power cord is NOT plugged into an electrical outlet.
Disconnect the positive side of the battery before installation. 
Connect the positive (red) and negative (black) terminal lugs to 
battery or load (lugs require a #2 square drive). Always use the 
proper size wire based on the amperage of the converter and 
the battery. When connecting to a battery, a breaker should be 
installed within 18

 

of the battery, connecting the battery posi-

tive to the line side of the breaker, and the IOTA unit to the load 
side. Connect “Chassis Bonding Lug” on the IOTA unit to vehicle 
chassis or other grounding source. Refer to Illustration 1.

120 VOLT A.C. INPUT

 

Plug the unit A.C. input cord into an appropriate 120-volt 3-wire 
grounded source. Refer to Illustration 2 for specifications of the 
cord provided with your DLS unit. See the Technical Specifica-
tions Chart on page 4 for maximum current draw and required 
input voltages.
DO NOT USE EXTENSION CORDS - Using an improper 
extension cord could result in a risk of fire and electric shock, 
and may result in property damage, personal injury or death.
DO NOT OPERATE THE DLS WITH A DAMAGED CORD OR 
PLUG. Have the cord or plug replaced immediately by qualified 
service personnel.

REVERSE POLARITY FUSES

The IOTA Battery Charger/Power Supply is protected against 
reverse polarity on the DC output. If a battery or the unit is 
hooked up incorrectly, the fuses will blow and can be easily 
replaced. Always use the same size and style fuse that came 
with the converter. To change the fuses, use a screwdriver 
to loosen the screws and remove the fuses. Always replace 
the fuses with the same type and rating. After inserting the 
new fuses, tighten the screws firmly. Apply 5 inch-pound  
maximum torque. DO NOT OVERTIGHTEN. Note: some 
DLS models require only one fuse. For these units, a small 
fiberglass spacer may be used in the empty fuse slot to aid 
with tightening.

IOTA DLS-48-20 Power Converter and DLS-54-13 Battery 
Chargers convert 120 volts nominal A.C. to volts D.C. As a 
power supply, the DLS-48-20’s tightly controlled regulation 
allows the user to operate any 12 volt nominal D.C. load up 
to the converter’s rated output current. As a battery char-
ger, the DLS-54-13 will maintain the battery, delivering its 
full-rated current when the battery capacity falls sufficiently 
low. The voltage is set to deliver its maximum current for 
the necessary period of time that minimizes undue stress 
to the battery caused by heating of its cells. This helps to 
ensure the longest possible life of the battery. Over time, 
as the battery nears its full capacity, the converter will float-
charge the battery to prevent self-discharge of its cells.  

PROTECTION FEATURES

The IOTA Power Converters/Battery Chargers are de-
signed with high quality components to help ensure 
years of continuous use. The unit is protected by multiple 
protection features for a long, trouble-free life.

1) Reverse Battery Polarity Protection. 2) Brown-Out In-
put Protection.
 3) Over-Current Protection - cycle by cycle 
peak limiting as well as rated current limiting to maximize 
the life of the converter. 4) Over-Temperature Protection. 
In addition, it is designed with a unique “proportional” fan 
control circuit. Fan speed is directly proportional to the 
converter’s internal ambient temperature. This enables 
the fan to turn on and off very slowly, minimizing unwanted 
fan-starting noise. 

The IOTA Power Converters/Battery Chargers are war-
ranted from defects in materials or workmanship for two 
years from date of retail purchase, and limits the remedies 
to repair or replacement. This warranty is valid only in 
the continental United States and Canada. For com-
plete warranty details, contact Customer Service or visit  
www.iotaengineering.com.

WARRANTY

PRODUCT DESCRIPTION

Reviews: