iOptron ZEQ25GT Instruction Manual Download Page 25

 
 

25

5.3.9. Upgrade RA & DEC 

Use this operation to upgrade 8408 hand controller, R.A. and DEC motor controller firmware. Please 

refer to iOptron online documents for ZEQ25 firmware upgrade details. The password is 

9999

 

5.4. Align  

This function is used for aligning the telescope. The hand controller provides “Polar Align”, which 

uses a set of 2 bright stars for polar alignment. This provides a viable polar alignment approach for those 
who can’t see the polar star or has a mount does not equip an iOptron AccuAlign

TM

 polar scope. The system 

also provides three alignment methods: “SolarSys Align”, “One Star Align”, and “Multi-Star Align”. The 
mount has to be at Zero Position before performing any star alignment. 

5.4.1. Polar Alignment 

Press the MENU button, then select “

Align

” and “

Polar Align

”. The HC will display the azimuth and 

altitude position of several bright stars near meridian. Select one that is visible with high altitude as 
Alignment Star A. Follow the HC instruction to move the Star A to the center of the eyepiece with the 
combination of Latitude Adjustment Knob and “

” or “

” button. Press ENTER to confirm. Next, select a 

bright star that is close to the horizon as the Alignment Star B. Center it using the Azimuth Adjustment Knob 
and “

” or “

” button (

The “

▲”

 and “

▼”

 buttons are not used here

). Press ENTER to confirm.  

The telescope will now slew back to Star A to repeat above steps. The iteration can be stopped 

when it is determined that the alignment error is at the minimum. Press BACK button to exit alignment 
procedure.  

NOTE: It is highly recommended to use an eyepiece with crossed-hair line for accurate centering.  

NOTE: The movement of the alignment star in your eyepiece may not be perpendicular but crossed, 

depends on its location in the sky. 

5.4.2. SolarSys Alignment 

Press MENU button and select “

Align

”. Select “

SolarSys Align

” and press ENTER for available 

alignment object.  

5.4.3. One-Star Alignment 

Press MENU button and select “

Align

”. Select “

One Star Align

” and press ENTER. A list of 

alignment stars that are above the horizon is computed based on your local time and location. With the 
mount at the “Zero Position,” use 

 and 

 buttons to select a star and press ENTER. Center the target in 

your eyepiece using arrow key. Press ENTER when finished. If your mount is well set up and polar aligned, 
one star alignment should be sufficient for good GOTO accuracy. To increase the accuracy you may 
choose to do multi star alignment. 

5.4.4. Multi-Star Alignment 

With iOptron’s multi-star alignment, you can choose two, three, or as many stars as you want to 

reduce the mount alignment offset.  

Press MENU button and select “

Align

”. Select “

Multi-Star Align

” in the align menu. A list of 

alignment stars that are above the horizon is computed based on your local time and location. With the 
mount is at the “Zero Position,” use 

 and 

 buttons to select first alignment star and press ENTER. 

Center the target in your eyepiece using arrow key. Press ENTER when finished. The hand controller will 
prompt you to choose the second star. If the star you choose is too close to the first one, the system will let 
you choose another one. When you are aligned with the second star, the two star alignment is finished. You 
can reject the suggested star if it is blocked by a tree or other obstruction.  

Summary of Contents for ZEQ25GT

Page 1: ...iOptron ZEQ25GT Balanced GoTo Equatorial Mount With Go2Nova 8408 Hand Controller Instruction Manual Product 7100 7101 and 7102...

Page 2: ...mplete Functions of Go2Nova 8408 Hand Controller 22 5 1 Slew to an Object 22 5 1 1 Solar System 22 5 1 2 Deep Sky Objects 22 5 1 3 Stars 22 5 1 4 Constellations 22 5 1 5 Comets 22 5 1 6 Asteroids 22 5...

Page 3: ...0 Appendix C Firmware Upgrade 32 Appendix D Computer Control an ZEQ25GT Mount 33 Appendix E Go2Nova Star List 34 IOPTRON TWO YEAR TELESCOPE MOUNT AND CONTROLLER WARRANTY 41 WARNING NEVER USE A TELESCO...

Page 4: ...axis servomotor with enhanced optical encoder for precise GOTO and accurate tracking iOptron AccuAligningTM calibrated polar scope with dark field illumination and easy polar alignment procedure allo...

Page 5: ...Tripod 7100 or 2 inch Tripod 7200 Tripod spreader One 10 4lbs 4 7 kg counterweight Counterweight shaft Dark field illuminating LED cable for model 7100 and 7200 with polar scope AC adapter 100V 240V...

Page 6: ...g Screw Polar Axis Cover Polar Scope Cover Polar Axis R A axis Azi Adj Knob Lat Adj Knob Lat Locking T bolt CW mounting nose Front CW position screw R A Drive Unit DEC Drive Unit Dovetail Saddle Main...

Page 7: ...o other iOptron accessories such as a laser pointer or a planetary dome control HBX Hand Box For connecting to an 8408 Hand Controller Reticle Power supply for the polar scope dark field illumination...

Page 8: ...scrolling Number Keys Input numerical values Also used to adjust slewing speeds 1 1X 2 2X 3 8X 4 16X 5 64X 6 128X 7 256X 8 512X 9 MAX Key Identify and display nearby bright stars or objects where the...

Page 9: ...ht Ascension of the telescope or R A 4 Declination Declination of the telescope or DEC 5 Azimuth Azimuth of the telescope north is 0 east 90 south 180 and west 270 6 Altitude Altitude of the telescope...

Page 10: ...Axis alignment equatorial mounts use a combination of both mount types described above The adjustable part of the mount moves in the Alt Az mode in order to align the R A axis also known as the mount...

Page 11: ...w Bottom Post Locking Screw to free the Bottom Latitude Adj Post and remove the Latitude Adj Knob Thread in evenly the adequate Latitude Adj Knob to Top and Bottom Latitude Adjustment Posts Reinstall...

Page 12: ...phone You will have to change this latitude setting every time you significantly change your night sky viewing location This setting directly affects the mount s tracking and GOTO accuracy Slightly lo...

Page 13: ...e CW through the shaft Use the CW Locking Screw to hold the CW in place Place Safety Cap back onto the shaft ZEQ25 comes with a 10 4 lbs 4 7kg counterweight It should be able to balance a total payloa...

Page 14: ...e on the worm assembly is kept at a minimum STEP 8 Connect Cables Connect DEC unit to the main control unit with a short straight RJ11 cable Connect the Go2Nova 8408 hand controller to the HC port on...

Page 15: ...ton is 300 minutes behind UT Los Angeles is 480 minutes behind UT Rome is 60 minutes ahead of UT Beijing is 480 minutes ahead of UT Sydney is 600 minutes ahead of UT All the time zones in North Americ...

Page 16: ...format by multiplying the decimal numbers by 60 For example N47 53 can be changed to N47 31 48 47 53 47 0 53 0 53 0 53x60 31 8 0 8 0 8x60 48 Therefore 47 53 47 31 48 or 47d31m48s Select N S Hemispher...

Page 17: ...e LED cable between Reticle plug located on the main unit and the LED socket at the bottom of the DEC axle as shown in Figure 18 The light intensity can be adjusted using the HC via Set Polar Scope Li...

Page 18: ...e MENU button then select Align and Polar Align The HC will display the azimuth and altitude position of several bright stars near meridian Select one that is visible with high altitude as Alignment S...

Page 19: ...19 Figure 20 Zero position...

Page 20: ...p the hand controller to correct any pointing discrepancy of the Zero Position and to improve the GOTO accuracy To perform One Star Align press MENU button scroll down to Align select One Star Align a...

Page 21: ...rns from the fully tightened position Ideally it should be at a position just deep enough to rid any free movements plays while force on the worm assembly is kept at a minimum 4 7 Turn Off the Mount W...

Page 22: ...named deep sky objects is included in Appendix E Messier Catalog consists of all 110 Messier objects NGC IC Catalog consists of 7 840 objects in NGC catalog and 5 386 objects in IC catalog To select...

Page 23: ...as one star alignment except that you choose the object to sync to One star align chooses the star object for you 5 3 Set Up Controller 5 3 1 Set Up Time Site Refer to STEP 9 in Section 3 2 5 3 2 Set...

Page 24: ...ount when it passes the meridian Telescope Flip will flip the telescope and continuous to track the object The third option is Continue to Track In this case the mount will keep tracking and the OTA c...

Page 25: ...recommended to use an eyepiece with crossed hair line for accurate centering NOTE The movement of the alignment star in your eyepiece may not be perpendicular but crossed depends on its location in th...

Page 26: ...he Go2Nova hand controller needs to record the PE first The periodic error of the worm gear drive will be used to correct periodic error The data will be lost when the power is turned off Here s how t...

Page 27: ...few times to go back to Set User Objects You may review the records or delete the ones you don t want it anymore Press BACK button to finish the operation Now you can slew to your favorite stars from...

Page 28: ...ephone calls So please contact iOptron first to avoid returning the mount for repair It is strongly suggested that to send technical questions to support ioptron com Call in the U S 1 781 569 0200 6 3...

Page 29: ...on Synchronous belt Gear Latitude adjustment range 0 60 Azimuth adjustment range 10 GPS Internal 32 channel GPS Polar Scope AccuAligningTM dark field illuminated Level indicator Level bubble Hand Cont...

Page 30: ...ect Messier Catalog NGC IC Catalog UGC Catalog Caldwell Catalog Herschel Catalog Named Object Messier Catalog NGC IC Catalog UGC Catalog Caldwell Catalog Herschel Catalog Named Stars Binary Stars SAO...

Page 31: ...te All Records Set User Objects Set User Objects Add A New Record Add A New Record Browse Records Browse Records Delete One Record Delete One Record Delete All Records Delete All Records To Zero Posit...

Page 32: ...The firmware in the 8408 hand controller and motor control boards can be upgraded by the customer Please check iOptron s website www iOptron com under Support Directory ZEQ Mounts select ZEQ25GT with...

Page 33: ...via ASCOM protocol you need 1 Download and install ASCOM Platform from http www ascom standards org Make sure you PC meet the software requirement Refer to the ascom standards website for details 2 D...

Page 34: ...Appendix E Go2Nova Star List Messier Catalog This table is licensed under the GNU Free Documentation License It uses material from the Wikipedia article List of Messier objects...

Page 35: ...024 Alkalurops 073 Dabih 122 Mintaka 171 Sulafat 025 Alkes 074 Deneb 123 Mira 172 Syrma 026 Almach 075 Deneb Algedi 124 Mirach 173 Talitha 027 Alnasl 076 Deneb Kaitos 125 Mirfak 174 Tania Australis 02...

Page 36: ...er 20 Cepheus Cep 64 Phoenix Phe 21 Cetus Cet 65 Pictor Pic 22 Chamaeleon Cha 66 Pisces Psc 23 Circinus Cir 67 Piscis Austrinus PsA 24 Columba Col 68 Puppis Pup 25 Coma Berenices Com 69 Pyxis Pyx 26 C...

Page 37: ...2 13 California Nebula 1499 43 Owl Nebula 3587 97 14 Cat s Eye Nebula 6543 44 Pelican Nebula 5070 15 Cocoon Nebula 5146 45 Phantom Streak Nebula 6741 16 Cone Nebula 2264 46 Pinwheel Galaxy 598 33 17 C...

Page 38: ...36 51 66 Cet 16 5 5 7 7 5 129752 17 Nu Aur 55 4 0 9 5 58502 52 Eps CMa 7 5 1 5 7 4 172676 Adhara 18 Ome Aur 5 4 5 0 8 0 57548 53 Tau CMa 8 2 4 4 10 11 173446 19 Eps Boo 2 8 2 5 4 9 83500 Izar 54 145 C...

Page 39: ...7 6 5 10 72509 87 Psi Dra 30 3 4 9 6 1 8890 122 Gam 1 Leo 4 4 2 2 3 5 81298 Algieba 88 26 Dra 1 7 5 3 8 0 17546 123 Iot Leo 1 7 4 0 6 7 99587 89 16 17 Dra 90 5 4 5 5 6 4 30012 124 54 Leo 6 6 4 3 6 3...

Page 40: ...ntaka 191 59 Ser 3 8 5 3 7 6 123497 157 Iot Ori 11 3 2 8 6 9 132323 Nair al saif 192 Zet Sge 8 5 5 0 8 8 105298 158 Lam Ori 4 4 3 6 5 5 112921 Meissa 193 Eta Sgr 3 6 3 2 7 8 209957 159 Sig Ori 13 3 8...

Page 41: ...to abuse misuse mishandling or unauthorized repair Further product malfunction or deterioration due to normal wear is not covered by this warranty IOPTRON DISCLAIMS ANY WARRANTIES EXPRESS OR IMPLIED W...