                                    SF6 P2 Instrument User Manual V1.2 

 

Unrivalled Gas Detect

ion.

                

Page 2 of 16

                                                      

ionscience.com

 

 

 

 

Declaration of conformity 

 

 

 

 

 

 

 

 

 

 

Name und Adresse des Herstellers / Manufacture´s name and address / 
ISM Deutschland GmbH, Laubach 30, 
 
Die ISM Deutschland GmbH bescheinigt die Konformität für das Produkt the product / ISM Deutschland GmbH dérclare la 
conformite du produit 
 
Bezeichnung / Product name : 

SF6-Raumluftmonitor / SF6-Roommonitor 

 
Typ / Type / Type: 

SF6 AREACHECK P2 

 
Mit den folgenden Bestimmungen / with applicable regulations / avec les directives suivantes 
 
EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG 
EMC Drective 89/336/EEC amended by 91/263/EWG, 92/31/EEC 
Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE 
Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG 
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC 
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE 
 
Angewendete harmonisierte Normen / Harmonized standards applied / Normes harmonisées utilisáes 
Sicherheit / Safety / Sécurité 
 
EN 61010-1 : 1993 / IEC (CEI) 1010- 
 
Überspannungskategorie / Overvoltage category / Catégorie de surtension: II 
 
Verschmutzungsgrad / Degree of pollution / Degré de pollution: 2 
 
Elektromagnetische Verträglichkeit / Electromagnetic compatibility / Compatibilité electromagnétique 
 
EN 50082-2: 1995 / VDE 0839 T82-2 
ENV 50140 : 1993 / IEC (CEI) 1001-4 
ENV 50141 : 1993 / IEC (CEI) 1000-4 
ENV 61000-4,2 : 1995 / IEC (CEI) 1000 
 
Prüfschärfe /Level / Niveau = 2 
EN 61000-4-4: 1995 / IEC (CEI) 1000 
 
Prüfschärfe /Level / Niveau = 3 
EN 50081-1 : 1992 / EN 55011 : 1991 / CISPR11 
 
Gruppe / group / groupe = 1, Klasse / Class / Classe = B 
 
Datum / Date / Date 
01.08.2005 
 
Unterschrift / Signature / Signatur 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
Hr. Becker 

 

Technical Director  

 

 
 

Summary of Contents for SF6 AREACHECK P2

Page 1: ...Unrivalled Gas Detection ionscience com Register your instrument online to receive your extended Warranty SF6 P2 Instrument User Manual V1 2...

Page 2: ...y Thank you for purchasing your Ion Science instrument The standard warranty of your instrument can be extended to up to two years To receive your extended warranty you must register your instrument o...

Page 3: ...inie 73 23 EWG erg nzt durch 93 68 EWG Low Voltage Equipment Directive 73 23 EEC amended by 93 68 EEC Directive des equipements basse tension 73 23 CEE amend e par 93 68 CEE Angewendete harmonisierte...

Page 4: ...rtup 7 Measuring interval 7 Indicator lights 7 Lamp test and manual reset 8 Configuration via the PC interface 9 Connecting to the host computer 9 User parameters 9 Changing the sensor unit 10 O2 sens...

Page 5: ...6 ionscience com Installation Location SF6 AREACHECK P2 is designed for indoor wall mounting Since SF6 tends to sink towards the ground in undisturbed air we suggest to place it approx 50 60 cm above...

Page 6: ...plies in case of power failure and whenever the instrument is taken into setup mode via the host computer interface via the RS232 connector The leftmost 6 position clamp block is provided for network...

Page 7: ...SF6 P2 Instrument User Manual V1 2 Unrivalled Gas Detection Page 6 of 16 ionscience com Network diagram...

Page 8: ...tomatically return to full sensitivity Since a reset is also performed when the instrument is taken into setup mode via the host computer interface the above also applies in this case After Power up o...

Page 9: ...s reflect the last sampling period s result in terms of alarm levels as designated On instruments equipped with the optional oxygen sensor these lights have the following additional functions The two...

Page 10: ...ard configuration also known as 9600 8 N 1 Further select none for the handshake protocol and TTY as emulation if available The option append CR for received lines should be checked for a more readabl...

Page 11: ...ensor Fit the replacement SmartSensor Power up the P2 insert fuse observing the hints below NOTE To precisely determine SF6 concentration SF6 AREACHECK P2 requires a reference value representing clean...

Page 12: ...easonable safety margin sensor life is fixed at one year no matter if shelfed or used this is due to the nature of galvanic cells in which the chemical reaction goes on at all times as long as oxygen...

Page 13: ...500 ppm O2 1 Mains power 100 240VAC 50 60Hz Power consumption 18 VA Operating temperature range 5 C 45 C Storage temperature range 20 C 60 C Operating humidity range 10 90 non condensing Max load rel...

Page 14: ...that your Extended Warranty Period has been activated and processed Full details along with a copy of our Warranty Statement can be found by visiting www ionscience com Service Ion Science is pleased...

Page 15: ...w ism d de Email info ism d de Italian Office ION Science Italia Via Emilia 51 c 40011 Anzola Emilia Bologna ITALY Tel 39 051 0561850 Fax 39 051 0561851 Web www ionscience com it Email info ionscience...

Page 16: ...V1 1 Layout and font update 28 01 13 SF6 P2 V1 1R Logo only 01 08 2017 SF6 P2 V1 2 Design update 05 05 2020 Disclaimer Information in this manual document is subject to change without notice and does...