background image

SEF100-SEF200

Heavy Duty Sewage Pumps

OPERATION MANUAL

Dated: 08/09/2016

Document Name: SEF100-SEF200_OM

Page 3 of 12

Register your product at www.ionproducts.net

CAUTION: 

These pumps are NOT to be 

installed in locations classified as 

hazardous in accordance with the National Electric 

Code, ANSI/NFPA 70.

WARNING: 

Do not introduce into any sewer, 

either  directly,  or  through  a  kitchen  waste 

disposal  unit  or  toilet:  Seafood  Shells,  Aquarium 

Gravel,  Cat  Litter,  Plastic  Objects,  Sanitary 

Napkins  or  Tampons,  Diapers,  Rags,  Disposable 

Wipes or Cloth, Medications, Flammable Material, 

Oil or Grease, Strong Chemicals, Gasoline. 

•  Operation against a closed discharge valve will 

cause premature bearing and seal failure on 

any pump.

•  Any wiring of pumps should be performed by a 

qualified electrician.

•  Cable should be protected at all times to avoid 

punctures, cuts, bruises, and abrasions-inspect 

frequently.

•  Never handle connected power cords with wet 

hands.

•  Never let cords or plugs lie in water outside the pit.

•  These pumps are offered in a three phase and 

single  phase  wiring  configuration.  Voltages  will 

vary according to the application and can be seen 

in the tables in this manual.

P

uMP

 I

nstallatIon

These important instructions must be followed for 

satisfactory performance of your pump. Before 

installation,  check  your  local  electrical  and  plumbing 

codes.

The sump or basin shall be sealed and vented in 

accordance with local plumbing codes. This pump is 

designed to pump domestic wastewater, nonexplosive 

and noncorrosive liquids and shall NOT be installed in 

locations classified as hazardous in accordance with 

the National Electrical Code (NEC) ANSI/ NFPA 70 

or Canadian Electric Code (CEC). The pump should 

never be installed in a trench, ditch, or hole with a dirt 

bottom. The legs will sink into the dirt and the suction 

will become plugged.

d

IMensIons

P

erforMance

Capacity (GPM)

Total Dynamic Head (ft.)

0

50

100

150

200

250

300

50

40

30

20

10

SEF100

SEF200

177

54

35

7

14

2

25

7

3” NPT

528

171

Summary of Contents for SEF100M03

Page 1: ...operator that the failure to follow an instruction may damage the pump and or the system Safety Warnings CAUTION Read these safety warnings first before installing servicing or operating any pump Befo...

Page 2: ...RNING Installation wiring and junction connections must be in accordance with the National Electric Code and all applicable state and local codes Requirements may vary depending on usage and location...

Page 3: ...Never handle connected power cords with wet hands Never let cords or plugs lie in water outside the pit These pumps are offered in a three phase and single phase wiring configuration Voltages will va...

Page 4: ...MFG Date 3 Phase Models Phase Amps L1 2 Volts L1 2 HP Amps L2 3 Volts L2 3 SN Amps L3 3 Volts L3 3 Model HP Volt Ph Nema Start Code FLA Cord Size Cord Type Cord O D Inches SEF100M21 1 60 230 1 1750 1...

Page 5: ...egs and connected to discharge pipe so that space is provided under pump for entrance of sewage Pump inlet should not be closer than 2 inches from bottom of sump It is not generally desirable to insta...

Page 6: ...oper motor rotation can result in poor pump performance and can damage the motor and or pump Identification Plate Note the numbers on the pumps identification plate and record in this manual for futur...

Page 7: ...tags or labels have been removed 5 Used in a heavy grease application 6 Used in applications exceeding the designed temperature range of 32 104 degrees F Troubleshooting Pump does not run and or just...

Page 8: ...091SW1027 091SW1027 SCREW 3 6 091SW1028 091SW1028 091SW1028 091SW1028 WASHER 4 1 091SWF104 091SWF204 091SWF231 091SWF241 STATOR ASSEMBLY 5 4 091SW1029 091SW1029 091SW1029 091SW1029 SCREW 6 2 091SW103...

Page 9: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 9 of 12 Register your product at www ionproducts net Exploded View 1 2 3 4 5 6 7 8 9 10 11...

Page 10: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 10 of 12 Register your product at www ionproducts net Notes...

Page 11: ...SEF100 SEF200 Heavy Duty Sewage Pumps OPERATION MANUAL Dated 08 09 2016 Document Name SEF100 SEF200_OM Page 11 of 12 Register your product at www ionproducts net Notes...

Page 12: ...correct a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unl...

Reviews: