background image

ION F15R 1RU 

10

TECHNICAL 

SPECIFICATIONS

 F15R-650

F15R-1200

F15R-1600

BATTERY

Battery voltage

12Vdc

24Vdc

24Vdc

Battery type & number

6V 7AH *2

6V7AH *4

6V 9AH *4

Charging  Current

 1A

Typical Recharge Time

4 hours

Easy battery replacement

YES

INDICATORS

Display

LCD

Alarm

Battery mode: Sounding every 30 seconds

Low Battery: Sounding every 2 seconds

Over Load: Sounding every 0.5 seconds

Fault: Continuous sounding

PHYSICAL

Dimensions (W * H * D) (mm) 433*44*216

433*44*485

ENVIRONMENT

Humidity

0-90 % RH @ 0-40°C (non-condensing)

Noise Level

Less than 40 dB

INTERFACE

RS232

Yes

USB

Yes

EPO

Yes

Smart Slot

Yes

REGULATION

Safety

CE

Standard warranty

3 Year Advance Replacement*

Summary of Contents for F15R

Page 1: ...info ionups com au www ionups com au P 1300 700 805 ION F15R 1RU Line interactive 650 1200 1600VA User Guide...

Page 2: ...ION F15R 1RU...

Page 3: ...__ 4 Routine Maintenance and Storage___________ 5 Important Safety Instructions_______________ 6 Basic Operation__________________________ 7 Software Download______________________ 8 Technical Specifi...

Page 4: ...battery for at least 8 hours is recommended to ensure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the...

Page 5: ...l not be operated for long periods of time 1 First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected to the UPS to avoid battery drain 2 The UPS shou...

Page 6: ...rt equipment microwave ovens or vacuum cleaners to UPS Do not plug the UPS input into its own output Do not allow liquids or any foreign object to enter the UPS Do not place beverages or any other liq...

Page 7: ...nnection and communication from the DB9 serial on the computer to the UPS unit The UPS communicates its status to the software ION F15R 1RU Line interactive UPS 650 1200 1600VA 6 USB Port This port al...

Page 8: ...oad Input Status Voltage Frequency Normal 229 9V 49 90Hz Event Action Events Recipient Settings Logs Events Logs Status Records Settings Schedule Shutdown Output Status Voltage Frequency Load Normal E...

Page 9: ...VR 118 Buck Ratio AVR 85 Ac voltage regulation batt mode 10 Frequency Range batt mode 50 60 1 Hz Transfer time 4ms typical waveform batt mode Pure Sine Wave Outlet IEC 4 THDv 5 Linear Load Full protec...

Page 10: ...cement YES INDICATORS Display LCD Alarm Battery mode Sounding every 30 seconds Low Battery Sounding every 2 seconds Over Load Sounding every 0 5 seconds Fault Continuous sounding PHYSICAL Dimensions W...

Page 11: ...T Voltage V Line mode Bat mode Alarm Fault Sound disable Press the mute key 3s to disable and enable the buzzer sound Bat mode battery capacity Line mode 1 Battery charging cycle lighting 2 Battery fu...

Page 12: ...wer to outlets Beep 1 time In Every 2 Seconds Utility Failure The UPS is providing battery power The rapid beeps indicate the battery will run out of power shortly Beep 1 time In Every 0 5 Second Over...

Page 13: ...PS Connect power cord then turn the UPS on Make sure that your spare fuse meets the specification Batteries are discharged Allow the unit to recharge for at least 4 hours Unit has been damaged by a su...