background image

SEH50-SEH100-SEH200

Heavy Duty High Head Sewage Pumps

OPERATION MANUAL

Dated: 03/22/2018

Document Name: SEH50-SEH100-SEH200_OM

Page 1 of 12

www.ionproducts.net

Introduction

Thank you for purchasing an Ion Technologies heavy 

duty high head  sewage pump. Take the time to read 

the instructions carefully before using this appliance. 

We strongly recommend that you keep this instruction 

manual in a safe place for future reference. 

Check the nameplate for your pump’s specification, 

refer to the table list.

Be careful not to exceed the given specifications in 

the use of your pump.

Each pump is individually factory tested to ensure 

proper performance. Closely following these 

instructions will eliminate potential operating problems 

assuring years of trouble-free service.

Most accidents can be avoided by using common 

sense.
IMPORTANT:  Ion Technologies is not responsible 

for losses, injury or death resulting from failure to 

observe these safety precautions, misuse, abuse 

or misapplication of pumps or equipment.

Marks & Meanings

CAUTION: 

Keep the pump equipment out of 

the reach of children! Warns that the failure to 

follow the directions given could cause serious risk to 

individuals or objects.

WARNING: 

This sign warns the operator that 

the failure to follow an instruction may damage 

the pump and/or the system.

Safety Warnings

CAUTION: 

Read  these  safety  warnings  first 

before  installing,  servicing,  or  operating  any 

pump.

Before Installation

This manual contains important information for the safe 

use of this product. Read this manual completely and 

follow the instructions carefully. Reasonable care and 

safe methods relating to the installation and operation 

of this product should be practiced. Check local codes 

and requirements before installation.

WARNING: 

Risk of Electrical Shock or 

Electrocution. May result in serious injury or 

death  or  fire  hazard.  Installer  must  disconnect  all 

electrical  sources  prior  to  installation,  handling  or 

servicing.  Only  qualified  personnel  may  install  this 

system. NFPA 70/National Electric Code (NEC) or 

local codes must be followed. System must be properly 

grounded according to NEC. Do not lift pump by power 

cord.

WARNING: 

Risk of Fire or Explosion. Do not 

smoke  or  use  open  flames  in  or  around  this 

system. This system is not intended for use in 

hazardous  locations  per  NFPA  70  National  Electric 

Code. Do not pump flammable liquids. Consult factory 

for  optional  equipment  rated  for  hazardous  location 

use.

CAUTION: 

Rotating machinery, 

amputation or severe lacerations can 

result. Keep clear of suction and discharge 

openings. DO NOT insert fingers into pump 

with power connected. 

Risk of serious cutting or 

Summary of Contents for SEH100M-03

Page 1: ...he operator that the failure to follow an instruction may damage the pump and or the system Safety Warnings CAUTION Read these safety warnings first before installing servicing or operating any pump B...

Page 2: ...NING Installation wiring and junction connections must be in accordance with the National Electric Code and all applicable state and local codes Requirements may vary depending on usage and location W...

Page 3: ...quently Never handle connected power cords with wet hands Never let cords or plugs lie in water outside the pit These pumps are offered in a three phase and single phase wiring configuration Voltages...

Page 4: ...odel HP Volt Ph Nema Start Code FLA Cord Size Cord Type Cord O D Inches SEH50M 11 0 5 60 115 1 3450 12 0 SOW 16 3 0 43 SEH50M 21 0 5 60 230 1 3450 6 0 SOW 16 3 0 43 SEH50M 03 0 5 60 208 3 3450 4 2 SOW...

Page 5: ...s and connected to discharge pipe so that space is provided under pump for entrance of sewage Pump inlet should not be closer than 2 inches from bottom of sump It is not generally desirable to install...

Page 6: ...per motor rotation can result in poor pump performance and can damage the motor and or pump Identification Plate Note the numbers on the pumps identification plate and record in this manual for future...

Page 7: ...ags or labels have been removed 5 Used in a heavy grease application 6 Used in applications exceeding the designed temperature range of 32 104 degrees F Troubleshooting Pump does not run and or just h...

Page 8: ...5010 2 BEARING 10 091EP5011 1 C RING 11 091EP7512 1 ROTOR ASSY 1 2 HP 091EP1012 1 ROTOR ASSY 1 0 HP 091SWH212 1 ROTOR ASSY 2 0 HP 12 091EP5013 1 SPRING WASHER 13 091EP5014 1 TOP COVER 14 091EP5015 1 G...

Page 9: ...High Head Sewage Pumps OPERATION MANUAL Dated 03 22 2018 Document Name SEH50 SEH100 SEH200_OM Page 9 of 12 www ionproducts net Exploded View 1 2 3 4 5 7 8 9 11 13 16 17 18 5 19 20 21 22 23 14 15 25 26...

Page 10: ...SEH50 SEH100 SEH200 Heavy Duty High Head Sewage Pumps OPERATION MANUAL Dated 03 22 2018 Document Name SEH50 SEH100 SEH200_OM Page 10 of 12 www ionproducts net Notes...

Page 11: ...SEH50 SEH100 SEH200 Heavy Duty High Head Sewage Pumps OPERATION MANUAL Dated 03 22 2018 Document Name SEH50 SEH100 SEH200_OM Page 11 of 12 www ionproducts net Notes...

Page 12: ...orrect a defect in a product shall extend the Warranty beyond the period set forth above Metropolitan shall not be obligated to remedy any defect where otherwise required pursuant to the Warranty unle...

Reviews: