Wiegand 50. Multiple selections are available, but the actual Wiegand format will depend on the
option in
[Wiegand output bits]
.
For Example: If the 26-bit Wiegand26, 34-bit Wiegand34a, 36-bit Wiegand36, 37-bit Wiegand37a
and 50-bit Wiegand50 are chosen in
[Wiegand Format]
, but 36 bits is selected in
[Wiegand
output bits]
, then the actual Wiegand format for use will be 36-bit Wiegand36.
Wiegand output bits
: Number of bits of Wiegand data. After choosing
[Wiegand output bits]
, the
device will use the set number of bits to find the suitable Wiegand format in
[Wiegand Format]
.
Failed ID:
It is defined as the output value of failed user verification. The output format depends on
the
[Wiegand Format]
setting. The default value ranges from 0 to 65535.
Site Code:
It is similar to device ID except that it can be set manually and repeatable with different
devices. The default value ranges from 0 to 256.
Pulse Width (us):
The width of pulse sent by Wiegand. The default value is 100 microseconds,
which can be adjusted within the range of 20 to 100 microseconds.
Pulse Interval (us):
The default value is 1000 microseconds, which can be adjusted within the range
of 200 to 20000 microseconds.
ID Type:
Output content after successful verification. User ID or card number can be chosen.
7
System
Set system parameters to meet user's demand as many as possible. Including the Date Time,
Attendance, Fingerprint and so on.