55
Flare 12M CXP User's Manual
To set the power-up profile write the
User Set Default Selector
register with a value from 1 to
8 for one of the user profiles or 0 for the factory profile.
3.14 Camera Reset
Write a 1 to the
Camera Reset
register to fully reset a Flare CXP camera. When the reset
command is received the camera will reload various settings from memory (serial number,
ADC ramp values, etc), reload the bad pixel table, and then load the power up profile. The
discovery process on the frame grabber will have to be re-initiated after the reset completes.
3.15 Control Packet CRC
For the complexity, and to relax a closed system frame grabber design, the CRC value in the
uplink control packets are not checked by default. To enable the CRC check write a 1 to the
CRC Check Enable
register. The register is saveable to the user profiles.
3.16 Device Discovery
To start imaging the Flare CXP cameras require the
StreamPacketSizeMax
bootstrap register
to be written with a non-zero, and a one must be written to the
Start Acquisition
register.
When sending out frames the LED on the back of the camera will be flashing green.
IO Industries Inc.
www.ioindustries.com
Revision 2.0