3. Installation cased (2 ducts).
Room at minimum frost free (
T > 1°C
).
Parameter « Air pipes» to be set « Outer/Outer »
Recommended room : living area (the heat loss of the water heater
remains in heated area), close to external walls. Avoid installation of water
heater and/or ducts near to sleeping rooms.
Examples :
•
Washing room,
•
Storage room,
•
Cupboard in entry area.
670mm
mini
Keep a free space of 500 mm in front of electric compartment and 300 mm around hydraulic
connections to allow easy access for maintenance.
100mm
mini
Respect the maximum length of ducts. Use insulated rigid ducts.
Plan grids at air entry and exit to avoid intrusion of objects or animals.
Attention, entry or exit grids with manual closing device are forbidden.