18
MSK-101-MM | Installation instructions v1.7 OCT 2018 | msk-101-mm_instructions_en_us v1.7 | © 2017-2018 Inxpect SpA
3
Appendix
Technical data
General specifications
Detection
method
Inxpect motion detection motor
based on FMCW radar
Frequency
Working band: 24–24.25 GHz
Transmission power: ≤ 13 dBm
Modulation: FMCW
Detection
interval
From 0.5 to 20 m (from 2 to 66 ft),
depending on the installation
conditions. Configurable in 30 cm
(1 ft) increments.
Field of
vision
Sensor horizontal plane: 90°
Sensor vertical plane: 30°
Height: from 0.5 to 3 m (from 1.6
to 10 ft)
Detection
speed
> 0.05 ms (2 in/s)
Relays
4 solid state relays, each max.
400 mA, 40 V dc(NO or NC
configurable, default NC)
Power supply
12 V dc *
Absorption
max. 100 mA
Electrical
protections
Inverted polarity
Overcurrent through integrated
fuse (max. 5 s @ 3 A)
Dimensions
103 x 110 x 81 mm (4.06 x 4.33 x
3.19 in)
Material
Technopolymer
Operating
temperature
From -40 to +70 °C (from -40 to
+158 °F)
Degree of
protection
IP66 and IP68
Cable
diameter
4–7 mm (0.16–0.27 in)
Approvals
Contains FCC ID: UXS-SMR-3X4
Compatible with EN50131-2-3
class IV grade 3**
Note
*: the device has been designed to be supplied by
an external power supply unit for alarm systems,
internally protected by a short-circuit.
Note
**: the instructions presented in this manual are
sufficient for meeting the requirements of standard
UL639. Installations not consistent with these
instructions could also comply with the standard.
MSK-101-MM dimensions
Perforated base dimensions
See "Perforated base dimensions" on page 21.
Disposal
MSK-101-MM contains electrical parts.
Dispose separately using the relative
recycling centers specified by the
government or local public authorities.
Correct disposal and recycling will
contribute to the prevention of potentially
harmful consequences to the