Hazardous Conditions, Devices and Cables: 

Hazardous electrical conditions can be present on/in power supply units and their cables. Disconnect the power cord 
and any other devices attached to the server before opening the case. Failing to follow safety procedures will increase 
the risk of personal injury or equipment damage.

Electrostatic Discharge (ESD) and ESD Protection: 

In most cases, ESD may damage disk drives, electronic boards and other parts. We recommend that you conduct 
installation only at an ESD free space. If not possible, perform ESD protection protocol by wearing anti-static wrist 
straps attached to the ground on any unpainted metal surface on your server during operation.

Installing or Removing Jumpers: 

A jumper is a short length conductor used to close, open or bypass part of an electronic circuit. Jumpers on InWin 
backplanes have a small tab on top that you can pick up with your fingertips. Grip the jumper carefully and plug the 
jumper to cover the jumper pins on the backplane. Once you need to remove the jumper, grip the jumper and carefully 
pull without squeezing.

CAUTION

To avoid damage and maintain your safety, please read the following terms listed below: 

1.  Do not populate hard drives and turn on the power until the system has stabilized. Make sure hard drives and other 

components are properly connected before turning on the system.

2.  Tighten or loosen all screws with a screwdriver.
3.  Apply the correct screws packed in the accessories box.
4.  For your safety, please have at least two people lift and install the unit in its designated area.
5.  Before mounting the unit to the cabinet, make sure the rail is installed correctly.
6.  When installing and removing any module or part, please use the handles.

Summary of Contents for IW-RS436-07

Page 1: ...4U NVMe Hybrid Storage Server User Manual IW RS436 07 ...

Page 2: ... typical office environment The location should be clean dry and free of airborne particles It should be placed in a well ventilated room and away from sources of heat including direct sunlight and radiators It should be kept away from sources of vibration or physical shock The space should be accommodated with a properly grounded wall outlet and with sufficient space to access the power supply co...

Page 3: ...to close open or bypass part of an electronic circuit Jumpers on InWin backplanes have a small tab on top that you can pick up with your fingertips Grip the jumper carefully and plug the jumper to cover the jumper pins on the backplane Once you need to remove the jumper grip the jumper and carefully pull without squeezing CAUTION To avoid damage and maintain your safety please read the following t...

Page 4: ...4 When you open the IW RS436 07 box the contents should include following 1 1 Box Contents 1 Product Introduction ...

Page 5: ...Accessories Box No Item No Item 1 Label x 1 4 Power LED 3 pin to 2 pin Adapter x 1 2 Motherboard Stand off Sockets and Screws x 12 5 Cable Ties 1 x 5 Cable Ties 2 x 6 3 2 5 HDD Screws x 108 6 Jumper for HDD Backplane x 2 ...

Page 6: ...TX CEB EEB M B mounting area 4 Rear backplane 12 80 Plus Platinum CRPS including PDB 5 80 x 38mm PWM hot swap top fans x 4 13 Rear 2 5 hot swap SSD trays x 2 6 80 x 38mm PWM hot swap bottom fans x 4 14 Rear I O shield mounting area 7 Front controls and indicator 15 Low profile PCI slot x 7 8 2 5 3 5 hot swap front trays x 24 16 2 5 3 5 hot swap rear trays x 12 1 2 3 4 8 7 9 6 5 14 15 16 13 12 11 1...

Page 7: ...button to activate user defined function 3 Power On Off Button with LED Green Solid on System is powered on N A Off System is off 4 Chassis ID Button with LED Blue Solid on Press the button to activate system identification 5 Hard Disk LED Amber Blinking System HDD accessing 6 System Fail LED Amber Solid on System Status Green Solid on System Status 7 LAN LED From top to bottom ranked LAN1 LAN4 Gr...

Page 8: ...or InWin OS disk backup module which supports two 2 5 12G SSDs and features hot swap function 4 System I O Depends on M B Specifications The I O shield should come with the motherboard or is provided by motherboard vendors 5 Low profile PCIe slots x 7 The slots support low profile cards The bracket should be removed before using 6 NVMe x 4 disk bays for faster hybrid storage performance ...

Page 9: ... to mount disks and can swap drives faster For a quick installation video please visit 07 Series HDD Tray Installation 2 2 HDD Tray Installation The IW RS436 07 s built in fan modules feature a tool less design which makes it easy to maintain For a quick installation video please visit 07 Series Fan Installation 2 3 Fan Installation The IW RS436 07 has a built in redundant power supply unit With t...

Page 10: ...Unit mm 435mm 450mm 635mm 435mm 435mm 330mm 300mm 435mm 635mm 285mm 375mm 5V 6pin front BP 5V 6pin front BP 8 pin CPU 12V 8pin rear BP 12V 8pin front BP 12V 8pin front BP 8 pin CPU 24 pin main motherboard 5V 6pin rear BP 4 pin rear 2 5 HDD BP PMBus ...

Page 11: ...2 ID LED ID LED RED BLACK Chassis ID Button with LED CN3 SYSTEM LED SYS LED RED BLACK System Fail LED CN4 ID Switch ID SW RED BLACK Chassis ID Button with LED CN5 Power LED PW LED RED BLACK Power ON OFF Button with LED CN6 LAN 1 LED LAN1 LED RED BLACK LAN LED CN7 HDD LED HDD LED RED BLACK HDD Active LED CN8 Power Switch PW SW RED BLACK Power ON OFF Button with LED CN9 Reset Switch RESET SW RED BLA...

Page 12: ...ue pulling the inner rail until the second stops Release the white slide tab to remove the inner rail Pull the latch on the middle rail upward and retract the middle rail back Align the chassis sidewall standoffs to the inner rail keyholes Slide the inner rail toward the front until the standoffs snap into place securing the rail to the chassis Repeat the same action on the other side When removin...

Page 13: ...Hang the front hooks of the outer rail at the front of the rack post holes Pull the rail bracket pins that go into the front post holes on the rack until they click The other side is the same process Repeat the installation steps 1 4 Once you would like to detach the bracket pull outward on the front and the rear hooks of the outer rail to release the bracket Repeat the same action to the other si...

Page 14: ...is to the stop position and then release the blue slide tab by either pulling the tab forward or pushing the tab back to continue Until reaching the second stop position release the blue slide tab again to continue Push the chassis into position on the rack completely Make sure that the front end of the chassis is aligned with the edge of the rack to complete the installation Step 1 Step 2 Step 3 ...

Page 15: ...ions for supporting Intel Xeon Scalable AMD EPYC family by adding NVMe support The active backplanes support state of the art SAS3 12Gbps HDD SSD and are also backward compatible with SAS 6Gbps SATA 6Gps and SATA 3Gps HDD SSD The backplane varies by order Please reference the IW RS436 07 Backplane Connection to complete the installation Front Host Side Front HDD Side ...

Page 16: ...Port 2 Port 1 Port 3 3 2 Slimline Backplane for NVMe Port 2 Port 1 Port 3 16 Rear Host Side Rear HDD Side Front Host Side Front HDD Side ...

Page 17: ...and 1 to connect the motherboard or RAID controller and port 3 for cascading Rear Host Side Rear HDD Side Location Description JD1 Firmware Programming Header JM1 M B Fan Speed Control JB1 System_Fail LED JB2 Mute_Button JC3 Firmware Programming Header JC1 JC2 I2C Header The IW RS436 07 supports NVMe SSDs through either Oculink x 12 or Slimline x 12 connectors and these two independent backplanes ...

Page 18: ...mance and avoid system failure InWin strongly recommends customers to choose the components from InWin s compatibility list All the components are tested in InWin s lab and assured the components are compatible with InWin s chassis You can download the latest updated device compatibility list from InWin s website ipc in win com If you need help with installation or troubleshooting you can contact ...

Page 19: ...Copyright In Win Development Inc All Rights Reserved ...