background image

 

 

15 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

  If the motherboard’s led power source is a 3-pin type, please use the 2-Pin to 3-Pin convertor   

adapter from the accessories box to connect. 

 

2.8  Installing the Slide Rail 

The  InWin  IW-RS104-07  is  a  rackmount  model,  which  supports  EIA-RS310D  standard 
cabinet and chassis racks. InWin provides standard slide rails to allow customers to mount 
the chassis onto the cabinet. 

 

2.8.1    Identifying the Slide Rail   

The slide rail by your order might be different. You can reference the quick installation 
guide inside the slide rail package and follow the instructions to mount the rail onto 
your cabinet or chassis rack. 

 
2.8.2

 

Installing the Slide Rail   

Step 1: Release the inner rail from the slide. 

 
 
 
 
 
 
 
 
 
 

No. 

Connector Name 

Color 

Front I/O Indication 

P2 

NMI Switch 

Black/Brown 

NMI Button 

P3 

Reset Switch 

Red/Orange 

Power Reset Button with LED 

P4 

LAN LED 4   

Yellow/Green 

LAN LED 

P5 

LAN LED 3 

Blue/Purple 

LAN LED 

P6 

LAN LED 2 

Gray/White 

LAN LED 

P7 

LAN LED 1 

Black/Brown 

LAN LED 

P8 

HDD LED 

Red/Orange 

HDD Active LED 

P9 

System LED 

Yellow/Green 

System Fail LED 

P10 

ID LED 

Blue/Purple 

Chassis ID Button with LED 

P11 

ID Switch 

Gray/White 

Chassis ID Button with LED 

P12 

Power LED

 

Black/Brown 

Power ON/OFF Button with LED 

P13 

Power Switch 

Red/Orange 

Power ON/OFF Button with LED 

USB 

USB 3.0 Connector  Black Flat 

USB 3.0 

Summary of Contents for IW-RS104-07

Page 1: ...IW IW IW IW RS104 RS104 RS104 RS104 07 07 07 07 User Manual User Manual User Manual User Manual ...

Page 2: ...d Expansion Card Installation 11 2 2 HDD Tray Installation 11 2 3 Backplane Connection 11 2 4 Fan Installation 11 2 5 Power Supply Installation 11 2 5 1 Power Supply Cable Information 12 2 6 Internal HDD Installation 14 2 7 Connecting Cables 14 2 7 1 Connecting Backplane Through SAS Connectors 14 2 7 2 Connecting LED Cable Front Control Panel and Front USB I O Ports 14 2 8 Installing the Slide Rai...

Page 3: ...3 Backplane Introduction 18 4 Compatibility Lists 19 5 Q A 20 6 Technical Support 21 ...

Page 4: ... from sources of heat including direct sunlight and radiators It should be kept away from sources of vibration or physical shock The space should be accommodated with a properly grounded wall outlet and with sufficient space to access the power supply cords The operating environment temperature should be around 0 C to 40 C 32 F to 104 F Heed Safety Instructions Before working with InWin IPC storag...

Page 5: ...er carefully and plug the jumper to cover the jumper pins on the backplane Once you need to remove the jumper grip the jumper and carefully pull without squeezing CAUTION To avoid damage and maintain your safety please read the following terms listed below 1 Do not populate hard drives and turn on the power until the system has stabilized Make sure hard drives and other components are properly con...

Page 6: ...D NVMe SAS SATA SFF 8639 x 4 Backplane 3 Host Mini SAS HD SFF 8643 x 1 HDD SAS SATA x 4 Cooling Fan 40 x 56mm PWM easy swap fans x 6 21500RPM modular design with anti vibration Expansion Slot Full height PCIe slot x 1 via riser card Material Material SGCC Thickness 1 0mm Rail Kit Supports 28 tool less ball bearing slide rails Product Dimensions D x W x H Chassis Only 676 5 x 438 x 43 4mm 26 6 x 17...

Page 7: ...4 Product Dimensions ...

Page 8: ...4 HDD Interface NVMe SAS SATA SFF 8639 x 4 Backplane 2 Oculink Backplane Dimensions W x H 416 6mm x 33mm Backplane Type Passive Host Interface Mini SAS HD SFF 8643 x 1 Oculink SFF 8611 x 4 HDD Interface NVMe SAS SATA SFF 8639 x 4 Backplane 3 SAS SATA Backplane Dimensions W x H 416 6mm x 33mm Backplane Type Passive Host Interface Mini SAS HD SFF 8643 x 1 HDD Interface SAS SATA x 4 ...

Page 9: ...6 1 Product Introduction 1 1 Box Contents When you open the IW RS104 07 box the contents should include following ...

Page 10: ...to 2 pin Adapter x 1 9 2 5 SSD screws x 24 4 Cable Ties and Mounts x 5 10 Backplane Jumper x 1 5 Motherboard Screws x 11 11 Single Power Supply Accessories a Countersunk Flat Head Screws x 2 b Oval Head Screws x 4 c Mounting Bracket x 1 6 Motherboard Stand off Sockets x 11 12 Redundant Power Supply Accessories a Screws x 6 b Mounting Brackets x 2 ...

Page 11: ...8 1 3 General Information When you open the chassis it should reflect the diagram s image ...

Page 12: ...2 Power ON OFF Button with LED Blue Solid on System is powered on Off System is off 3 NMI Button No LED function Press the button to activate user defined function 4 System Reset Button No LED function Press the button to activate system reset 5 USB3 0 Connector No LED function USB devices connections 6 LAN LED LAN1 LAN4 Amber Blinking Link between system and network Off No data transmission or re...

Page 13: ...rence InWin compatibility list to select the compatible models 2 System I O Depends on M B Specifications InWin offers a customized service for 1U I O shield For more information please contact InWin s sales reps 3 Full Height PCIe Slot x 1 The slot supports standard high profile cards The bracket should be removed before using ...

Page 14: ...tion video please visit 07 Series HDD Tray Installation 2 3 Backplane Connection The IW RS104 07 supports three high end backplanes including Slimline Oculink and Mini SAS HD For a quick installation video please visit 07 Series SAS SATA Backplane Connection and 07 Series Oculink and Slimline Backplane Connection 2 4 Fan Installation The IW RS104 07 s built in fan modules feature a tool less desig...

Page 15: ...12 2 5 1 Power Supply Cable Information 650W Single PSU Cable Information Length Unit mm ...

Page 16: ...13 750W Redundant PSU Cable Information Length Unit mm ...

Page 17: ... SATA 6Gps and SATA 3Gps HDD SSD Some of the backplanes support NVMe SSDs through either Oculink x 4 or Slimline x 4 connectors 2 7 1 Connecting Backplane Through SAS Connectors The InWin IW RS104 07 needs the SAS cable to connect to the backplane and your motherboard or RAID controller InWin provides verified SAS cables for installation please contact InWin sales reps to get more information 2 7 ...

Page 18: ...nstructions to mount the rail onto your cabinet or chassis rack 2 8 2 Installing the Slide Rail Step 1 Release the inner rail from the slide No Connector Name Color Front I O Indication P2 NMI Switch Black Brown NMI Button P3 Reset Switch Red Orange Power Reset Button with LED P4 LAN LED 4 Yellow Green LAN LED P5 LAN LED 3 Blue Purple LAN LED P6 LAN LED 2 Gray White LAN LED P7 LAN LED 1 Black Brow...

Page 19: ...the arrows show Step 3 Install the outer rails and the brackets onto the rack 2 8 3 Mounting the chassis onto the cabinet Step 1 Make sure the ball bearing retainer is at the forefront Step 2 Insert the inner rail to the outer rail which has already locked up on the cabinet ...

Page 20: ...17 Step 3 Mount the inner rail onto the chassis by the direction which the arrows show on the image Step 4 Tighten the thumb screws to secure the chassis ...

Page 21: ...der Please reference the backplane user guide to complete the installation The download link is at the download section of each product Please visit the InWin website ipc in win com SAS3 Backplane Top Side Bottom Side Oculink Backplane Top Side Bottom Side ...

Page 22: ...ut 3 GND FAN1 FAN12 Connect to fan modules The backplane supports up to 12 fan modules 4 Compatibility Lists To reach the best performance and avoid system failure InWin strongly recommends customers to choose the components from InWin s compatibility list All the components are tested in InWin s lab and assured the components are compatible with InWin s chassis You can download the latest updated...

Page 23: ...he best performance we recommend following the motherboard or RAID controller vendors instructions d Does the chassis support SSDs or flash NVMe drives A SAS SATA and NVMe SSD connections can be attached to the InWin IW RS104 07 We recommend customers refer to InWin s compatibility list to confirm if the SSDs are listed or please contact InWin s sales reps for better reference e If I don t need th...

Page 24: ...t a solid hardware RAID system it is required However whether you should use the RAID controller card or not depends on your purpose and budget We recommend discussing with InWin s channel partners for their suggestions i Where can I buy the SAS cable A The 12Gb SAS to 4 SATA or 12Gb SAS to 6Gb SAS are standard cables that you can easily buy from many vendors You can buy the verified cable from In...

Reviews: