InWin IW-MS08 User Manual Download Page 3

 

 

1

 

 

PREFACE

 

Thank

 

you

 

for

 

choosing

 

the

 

InWin

 

IW

MS08

 

SMB

 

Server.

 

This

 

manual

 

is

 

written

 

for

 

system

 

technicians

 

who

 

are

 

responsible

 

for

 

installation,

 

troubleshooting,

 

managing

 

and

 

repairing

 

this

 

server

 

chassis.

 

This

 

document

 

provides

 

the

 

overview

 

of

 

all

 

the

 

features

 

of

 

the

 

chassis,

 

a

 

list

 

of

 

accessories

 

or

 

other

 

components

 

you

 

may

 

need

 

to

 

finish

 

the

 

installation,

 

troubleshooting

 

methods

 

and

 

instructions

 

on

 

adding

 

and

 

removing

 

components

 

on

 

the

 

InWin

 

IW

MS08

 

SMB

 

Server.

 

For

 

the

 

latest

 

version

 

of

 

this

 

manual,

 

you

 

may

 

visit

 

InWin’s

 

server

 

website.

 

 
 

SAFETY

 

INFORMATION

 

To

 

ensure

 

a

 

safe

 

and

 

smooth

 

operation

 

of

 

your

 

InWin

 

IW

MS08

 

SMB

 

Server,

 

it

 

is

 

essential

 

that

 

you

 

choose

 

an

 

appropriate

 

location

 

for

 

the

 

system,

 

provide

 

an

 

appropriate

 

operating

 

environment

 

and

 

supply

 

an

 

adequate

 

amount

 

power

 

for

 

all

 

components

 

of

 

the

 

system.

 

As

 

you

 

plan

 

for

 

installation,

 

follow

 

the

 

guidelines

 

below

 

to

 

ensure

 

that

 

the

 

system

 

and

 

its

 

environment

 

are

 

safely

 

and

 

appropriately

 

positioned

 

for

 

efficient

 

operation

 

and

 

service.

 

Your

 

system

 

should

 

be

 

installed

 

and

 

serviced

 

only

 

by

 

a

 

qualified

 

technician.

 

 

Environment

 

Selection:

   

The

 

system

 

is

 

designed

 

to

 

operate

 

in

 

a

 

typical

 

office

 

environment:

   

 

The

 

location

 

should

 

be

 

clean,

 

dry

 

and

 

free

 

of

 

airborne

 

particles.

   

 

It

 

should

 

be

 

placed

 

in

 

a

 

well

ventilated

 

room,

 

and

 

away

 

from

 

sources

 

of

 

heat

 

including

 

direct

 

sunlight

 

and

 

radiators.

   

 

It

 

should

 

be

 

kept

 

away

 

from

 

sources

 

of

 

vibration

 

or

 

physical

 

shock.

   

 

The

 

space

 

should

 

be

 

accommodated

 

with

 

a

 

properly

 

grounded

 

wall

 

outlet,

 

and

 

with

 

sufficient

 

space

 

to

 

access

 

the

 

power

 

supply

 

cords.

   

 

The

 

operating

 

environment

 

temperature

 

should

 

be

 

around

 

0°C

 

to

 

40°C

 

(32°F

 

to

 

104°F).

 

 

Heed

 

Safety

 

Instructions:

   

Before

 

working

 

with

 

InWin

 

IPC/storage/SMB

 

server

 

products,

 

we

 

strongly

 

recommend

 

you

 

use

 

this

 

guide

 

as

 

a

 

reference

 

and

 

follow

 

the

 

safety

 

instructions.

 

The

 

instructions

 

in

 

this

 

manual

 

will

 

help

 

you

 

ensure

 

and

 

maintain

 

compliance

 

with

 

existing

 

product

 

certifications

 

and

 

approvals.

 

Follow

 

the

 

described,

 

regulated

 

components

 

mentioned

 

in

 

this

 

manual.

 

Use

 

of

 

non

UL

 

listing

 

products

 

or

 

other

 

regulators

 

may

 

not

 

comply

 

with

 

product

 

regulations

 

in

 

the

 

region(s)

 

in

 

which

 

the

 

product

 

is

 

sold.

   

 

System

 

Power

 

On/Off:

   

The

 

power

 

button

 

DOES

 

NOT

 

totally

 

turn

 

off

 

the

 

system

 

AC

 

power.

 

To

 

remove

 

the

 

power

 

of

 

the

 

system,

 

you

 

must

 

unplug

 

the

 

AC

 

power

 

cord

 

from

 

the

 

outlet

 

or

 

the

 

system’s

 

power

 

supply

 

units.

 

Make

 

sure

 

the

 

power

 

cord

 

is

 

unplugged

 

before

 

you

 

open

 

the

 

chassis

 

or

 

add/remove

 

any

 

components.

   

 

Hazardous

 

Conditions,

 

Devices

 

and

 

Cables:

   

Hazardous

 

electrical

 

conditions

 

can

 

be

 

present

 

on/in

 

power

 

supply

 

units

 

and

 

their

 

cables.

 

Disconnect

 

the

 

power

 

cord

 

and

 

any

 

other

 

devices

 

attached

 

to

 

the

 

server

 

before

 

opening

 

the

 

case.

 

Summary of Contents for IW-MS08

Page 1: ...IW MS08 User Manual...

Page 2: ...External 2 5 HDD 10 2 2 4 Installing the Internal 2 5 HDDs SSDs 11 2 2 5 Removing the Internal 2 5 HDDs SSDs for OS 12 2 3 Installing and Removing the Fans 13 2 3 1 Replacing the Middle Fan Modules 13...

Page 3: ...It should be placed in a well ventilated room and away from sources of heat including direct sunlight and radiators It should be kept away from sources of vibration or physical shock The space should...

Page 4: ...ou can pick up with your fingertips Grip the jumper carefully and plug the jumper to cover the jumper pins on the backplane Once you need to remove the jumper grip the jumper and carefully pull withou...

Page 5: ...SECC Thickness 1 0mm Product Dimensions DxWxH w o Front Door 513 x 170 x 340mm 20 2 x 6 7 x 13 4 Package Dimension DxWxH 630 x 450 x 310mm Weight Net Weight 10 37kg Gross Weight 12 52kg Cubic Feet 3...

Page 6: ...4 1 Product Introduction 1 1 Box Contents When you open the IW MS08 box the contents should include the following...

Page 7: ...ld reflect the diagram s image 80 x 25 mm PWM Fan x 2 Micro ATX Mini ITX M B Supported 1U Redundant 300W Or 1U Single 500W or 1U Flex 315W PSU 80 x 25 mm PWM Fan x 2 4500 RPM Front Bezel with Lock Sli...

Page 8: ...OFF Button with LED Blue Solid on System is powered on N A Off System is off 2 System Reset N A Press the button to reset system 3 USB3 0 Connector N A USB devices connection 4 LAN LED Amber Blinking...

Page 9: ...unted redundant single or Flex PSUs 2 System I O Depends on M B Specifications The I O shield should come with the motherboard or provided by motherboard vendors 3 4 Full Height PCI E Slots The slots...

Page 10: ...sis Step 2 Pull the hand hole on the side panel backwards and remove it from the chassis Step 3 If necessary repeat Step 2 to remove the other side panel Step 1 Step 2 Step 3 2 2 Installing and Removi...

Page 11: ...n the door Step 2 Press the release tab then pull the handle outward to reveal the disk tray Step 3 Place the hard drive into the tray Secure the hard drive on the tray with 4 screws Step 4 Insert the...

Page 12: ...5 HDD tray then remove the 3 5 HDD Step 3 Refer to steps 4 5 of 2 2 1 Step 2 2 2 3 Installing an External 2 5 HDD Step 1 Refer to step 1 of 2 2 1 to open the front door Step 2 Remove the 2 5 HDD tray...

Page 13: ...SSDs Step 1 Loosen the thumbscrew counterclockwise and take off the HDD trays Step 2 Insert the hard drive into the tray and use 4 screws to secure the HDD on the HDD tray Repeat this step to install...

Page 14: ...Step 1 Unplug the HDD cables Step 2 Refer to step 1 of 2 2 4 to remove the HDD trays Step 3 Loosen 4 screws on the bottom of the tray then remove the 2 5 HDD Repeat this step to uninstall the second 2...

Page 15: ...ing the Middle Fan Modules Step 1 Choose the fan that needs to be replaced and unplug the fan cables Release both sides clips of the fan holder to pull out the fan bracket Step 2 Push the new fan back...

Page 16: ...4 screws on the fan housing corners to remove the fan from the chassis Step 2 Place the new fan into the position and tighten the 4 screws to secure it Step 3 Connect the fan to the motherboard cable...

Page 17: ...h the power supply module into the PSU mounting area 2 4 1 Installing a Single PSU Step 1 Secure the PSU mounting bracket to the middle of the chassis Step 2 Tighten the 2 screws to secure the single...

Page 18: ...Use the 2 screws to secure the rear bracket to the back of the redundant PSU Step 3 Place the PSU with the bracket to the rear of the chassis Step 4 Align the screws holes to the redundant PSU front...

Page 19: ...ard Before installing the motherboard please find the I O shield from your motherboard package and install it into the system I O window Refer to 1 2 2 If you cannot find the I O shield please check w...

Page 20: ...1 Connecting the HDD Backplane Through SAS Connectors Connect the SAS cable to the backplane and your motherboard or RAID controller InWin provides a verified SAS cable for installation please contac...

Page 21: ...Purple White LAN LED USB 3 0 Connector Black Flat USB 3 0 If the LED power connector on the motherboard is 3 pin please use the 2 to 3 Pin convertor from the accessory box 2 7 Close the Chassis Step 1...

Page 22: ...InWin website https www in win com en ipc server Top Side Bottom Side 4 Compatibility Lists To reach the best performance and avoid system failure InWin strongly recommends users to choose the compone...

Page 23: ...IW MS08 supports 2 internal disks yet the disk mirroring is defined by your motherboard or your RAID 1 controller card Please check the vendor s guide to mirror your OS disks properly f Can it suppor...

Reviews: