PREFACE

Thank you for choosing the InWin IW-RS316-07 storage server. This manual is written for system technicians who 
are responsible for installation, managing and repairing this server chassis. This document provides an overview of 
all the features of the chassis, a list of accessories or other components you may need to finish the installation and 
instructions on adding and removing components in the InWin IW-RS316-07. For the latest version of this manual, you 
may visit InWin’s server website.

SAFETY INFORMATION

To ensure a safe and smooth operation of your InWin IW-RS316-07, it is essential that you choose an appropriate 
location for the system, provide an appropriate operating environment and supply an adequate amount of power for 
all components of the system. As you plan for installation, follow the guidelines below to ensure that the system and its 
environment are safely and appropriately positioned for efficient operation and service. Your system should be installed 
and serviced only by a qualified technician.

Environment Selection:

The system is designed to operate in a typical office environment:
• The location should be clean, dry and free of airborne particles.
• It should be placed in a well-ventilated room, and away from sources of heat including direct sunlight and radiators.
• It should be kept away from sources of vibration or physical shock.
• The space should be accommodated with a properly grounded wall outlet, and with sufficient space to access the 
    power supply cords.
• The operating environment temperature should be around 0°C to 40°C (32°F to 104°F).

Heed Safety Instructions: 

Before working with InWin IPC/storage/SMB server products, we strongly recommend you use this guide as a reference 
and follow the safety instructions. The instructions in this manual will help you ensure and maintain compliance with 
existing product certifications and approvals. Follow the described, regulated components mentioned in this manual. 
Use of non-UL listing products or other regulators may not comply with product regulations in the region(s) in which 
the product is sold. 

System Power On/Off: 

The power button DOES NOT totally turn off the system AC power. To remove the power of the system, you must 
unplug the AC power cord from the outlet or the system’s power supply units. Make sure the power cord is unplugged 
before you open the chassis, add or remove any components.

Summary of Contents for Cobra IW-RS316-07

Page 1: ...3U NVMe Hybrid Storage Server User Manual IW RS316 07 ...

Page 2: ... typical office environment The location should be clean dry and free of airborne particles It should be placed in a well ventilated room and away from sources of heat including direct sunlight and radiators It should be kept away from sources of vibration or physical shock The space should be accommodated with a properly grounded wall outlet and with sufficient space to access the power supply co...

Page 3: ...to close open or bypass part of an electronic circuit Jumpers on InWin backplanes have a small tab on top that you can pick up with your fingertips Grip the jumper carefully and plug the jumper to cover the jumper pins on the backplane Once you need to remove the jumper grip the jumper and carefully pull without squeezing CAUTION To avoid damage and maintain your safety please read the following t...

Page 4: ...4 When you open the IW RS316 07 box the contents should include following 1 1 Box Contents 1 Product Introduction ...

Page 5: ...1 2 Accessories Box No Item No Item 1 Label x 1 4 Power LED 3 pin to 2 pin Adapter x 1 2 Motherboard Stand off Sockets and Screws x 12 5 Cable Ties and Mounts x 5 3 2 5 HDD Screws x 60 6 Jumper for HDD Backplane x 2 ...

Page 6: ... ODD 2 Top cover screwless open button 3 80 x 38mm PWM hot swap fans x 4 10 Internal disk bracket for slim ODD 4 Backplane 11 80 Plus Platinum CRPS including PDB 5 Front controls and indicator 12 Rear 2 5 hot swap SSD trays x 2 6 2 5 3 5 hot swap trays x 16 13 ATX CEB EEB M B mounting area 7 Pull tab 14 Rear I O shield mounting area 8 USB 3 0 x 2 15 Full height PCI Slots x 7 16 Slide rail mounting...

Page 7: ...button to activate user defined function 3 Power On Off Button with LED Green Solid on System is powered on N A Off System is off 4 Chassis ID Button with LED Blue Solid on Press the button to activate system identification 5 Hard Disk LED Amber Blinking System HDD accessing 6 System Fail LED Amber Solid on System Status Green Solid on System Status 7 LAN LED From top to bottom ranked LAN1 LAN4 Gr...

Page 8: ...in OS disk backup module which supports two 2 5 12G SSDs and features hot swap function 4 System I O Depends on M B Specifications The I O shield should come with the motherboard or is provided by motherboard vendors 5 Full height PCIe slots x 7 The slots support full height cards The bracket should be removed before using 8 1 3 2 Rear Panel Configuration ...

Page 9: ...DD The extra storage spaces can provide users to meet their storage demands For a quick installation video please visit 07 Series HDD Tray Installation 2 2 HDD Tray Installation 2 2 1 Internal HDD Installation The IW RS316 07 s built in fan modules feature a tool less design which makes it easy to maintain For a quick installation video please visit 07 Series Fan Installation 2 3 Fan Installation ...

Page 10: ...rmation Length Unit mm PMBUS 24 Pin Main Motherboard 4 Pin Rear 2 5 HDD BP 8 Pin CPU PMBus 340mm 280mm 350mm 450mm 150mm 150mm 250mm 6 Pin BP 430mm SATA 15 pin Internal HDD 8 Pin CPU 380mm 8 Pin BP 380mm 8 Pin BP 450mm 6 Pin BP 680mm ...

Page 11: ...2 ID LED ID LED RED BLACK Chassis ID Button with LED CN3 SYSTEM LED SYS LED RED BLACK System Fail LED CN4 ID Switch ID SW RED BLACK Chassis ID Button with LED CN5 Power LED PW LED RED BLACK Power ON OFF Button with LED CN6 LAN 1 LED LAN1 LED RED BLACK LAN LED CN7 HDD LED HDD LED RED BLACK HDD Active LED CN8 Power Switch PW SW RED BLACK Power ON OFF Button with LED CN9 Reset Switch RESET SW RED BLA...

Page 12: ...nue pulling the inner rail until the second stops Release the white slide tab to remove the inner rail Pull the latch on the middle rail upward and retract the middle rail back Align the chassis sidewall standoffs to the inner rail keyholes Slide the inner rail toward the front until the standoffs snap into place securing the rail to the chassis Repeat the same action on the other side When removi...

Page 13: ...Hang the front hooks of the outer rail at the front of the rack post holes Pull the rail bracket pins that go into the front post holes on the rack until they click The other side is the same process Repeat the installation steps 1 4 Once you would like to detach the bracket pull outward on the front and the rear hooks of the outer rail to release the bracket Repeat the same action to the other si...

Page 14: ...is to the stop position and then release the blue slide tab by either pulling the tab forward or pushing the tab back to continue Until reaching the second stop position release the blue slide tab again to continue Push the chassis into position on the rack completely Make sure that the front end of the chassis is aligned with the edge of the rack to complete the installation Step 1 Step 2 Step 3 ...

Page 15: ...MD EPYC family by adding NVMe support The active backplanes support state of the art SAS3 12Gbps HDD SSD and are also backward compatible with SAS 6Gbps SATA 6Gps and SATA 3Gps HDD SSD The backplane varies by order Please reference the backplane user guide to complete the installation The download link is at the download section of each product Please visit the InWin website ipc in win com Host Si...

Page 16: ...8 or Slimline x 8 connectors and these two independent backplanes equipped with expander onboard are backward compatible with Mini SAS HD For a quick installation video please visit 07 Series SAS SATA Backplane Connection and 07 Series Oculink and Slimline Backplane Connection Please use the SFF 8643 cable to connect the expander port 1 and port 2 to the motherboard or RAID HBA controller card and...

Page 17: ...e and avoid system failure InWin strongly recommends customers to choose the components from InWin s compatibility list All the components are tested in InWin s lab and assured the components are compatible with InWin s chassis You can download the latest updated device compatibility list from InWin s website ipc in win com If you need help with installation or troubleshooting you can contact your...

Page 18: ...Copyright In Win Development Inc All Rights Reserved ...

Reviews: