IPE300 series engineering VFD
Technical data
-336-
You can learn the maximum length of the motor cable through the running parameters of the VFD. To
understand the accurate maximum cable length for using an external EMC filter, contact the local
INVT office.
For details about the environment categories, see section “EMC regulations”.
B.5 Application standards
The following table describes the standards that VFDs comply with.
EN/ISO 13849-1
Safety of machinery
––Safety-related parts of control systems––Part 1:
General principles for design
IEC/EN 60204-1
Safety of machinery. Electrical equipment of machines. Part 1: General
requirements
IEC/EN 62061
Safety of machinery
––Safety-related functional safety of electrical,
electronic, and programmable electronic control systems
IEC/EN 61800-3+A1
Adjustable speed electrical power drive systems. Part 3: EMC
requirements and specific test methods
IEC/EN 61800-5-1+A1
Adjustable speed electrical power drive systems
––Part 5-1: Safety
requirements
—Electrical, thermal and energy
IEC/EN 61800-5-2
Adjustable speed electrical power drive systems
––Part 5-2: Safety
requirements
––Function
B.5.1 CE marking
The CE marking on the VFD nameplate indicates that the VFD is CE-compliant, meeting the
regulations of the European low-voltage directive (2014/35/EU) and EMC directive (2014/30/EU).
B.5.2 EMC compliance declaration
European union (EU) stipulates that the electric and electrical devices sold in Europe cannot generate
electromagnetic disturbance that exceeds the limits stipulated in related standards, and can work
properly in environments with certain electromagnetic interference. The EMC product standard (EN
61800-3) describes the EMC standards and specific test methods for adjustable speed electrical
power drive systems. Our products have been compliant with these EMC regulations.
B.6 EMC regulations
The EMC product standard (EN 61800-3) describes the EMC requirements on VFDs.
Application environment categories:
First environment: Civilian environments, including application scenarios where VFDs are directly
connected to the civil power supply low-voltage grids without intermediate transformers.
Second environment: All environments except those in Category I.
VFD categories:
C1: Rated voltage lower than 1000 V, applied to environments of Category I.
Summary of Contents for IPE300 Series
Page 1: ...IPE300 Series Engineering VFD...
Page 3: ......