Goodrive3000 series medium voltage VFD
Product overview
-9-
Description
Specifications
Temperature of
running
environment
-10°C
– +50°C. Derating is required when the ambient temperature exceeds
40°C.
Relative humidity 5%95%
Storage
temperature
-40°C
–+70°C
Altitude
Less than 1000 meters
When the VFD installation site altitude exceeds 1000 meters, derate by 1%
for every increase of 100 meters.
IP rating
Main module: IP00
Cabinet of a standard product: IP20, IP54
2.4 Product ratings
2.4.1 Goodrive3000 two-quadrant VFD main ratings
Table 2-5 Goodrive3000 two-quadrant VFD main ratings
VFD model
Rated power (kW)
Rated input current (A) Rated output current (A)
U
N
=660V
GD3000-01-110G-06
110
118
120
GD3000-01-160G-06
160
165
175
GD3000-01-200G-06
200
210
220
GD3000-01-250G-06
250
255
270
GD3000-01-315G-06
315
334
350
GD3000-01-400G-06
400
411
430
GD3000-01-500G-06
500
518
540
GD3000-01-630G-06
630
668
700
GD3000-01-800G-06
800
822
860
VFD model
Rated power (kW)
Rated input current (A) Rated output current (A)
U
N
=1140V
GD3000-01-055G-12
55
34
36
GD3000-01-075G-12
75
47
50
GD3000-01-090G-12
90
56
60
GD3000-01-110G-12
110
68
73
GD3000-01-132G-12
132
82
85
GD3000-01-160G-12
160
98
104
GD3000-01-200G-12
200
122
128
GD3000-01-250G-12
250
150
160
GD3000-01-315G-12
315
185
195
GD3000-01-400G-12
400
235
250
GD3000-01-500G-12
500
300
310
GD3000-01-630G-12
630
380
395
GD3000-01-800G-12
800
480
500
GD3000-01-1000G-12
1000
600
620
VFD model
Rated power (kW)
Rated input current (A) Rated output current (A)
U
N
=3300V
GD3000-01-1250G-33
1250
260
280