INVT 4KW Quick Installation Manual Download Page 3

 

 

 

INVT 6-17kW

 Series   

PV Grid-tied Inverter

 

Quick Installation Guide 

 

 

 

 Only qualified electricians are allowed to install  the 

inverter. 

 Do not put and install the inverter on or close to 

combustible materials.   

 Install the inverter away from electronic devices with 

strong

 

electromagnetic interference. 

 Keep the installation  site away from children and 

other public places.   

 Remove the metal jewelry such as ring and bracelet 

before installation and electrical connection to avoid 

electric shock.   

 The inverter input voltage does not exceed the 

maximum input voltage; otherwise inverter  damage 

may occur.   

 The positive and negative pole of solar modules can 

not be grounded, otherwise irrecoverable damage 

may occur.   

 Ensure  the proper grounding  of the inverter, 

otherwise, improper connection or no grounding may 

cause stop of the inverter. 

 Ensure reliable installation and electrical connection.   

 

Unpacking inspection 

Inspect the information of the order and the name plate to ensure the 

product are the ordered one and no damage to the package. If any 

problem, contact the supplier as soon as possible.   

Table 

Packing list of three-phase inverter: 

Models 

6kW/7kW/

8kW/9kW 

10kW  12kW  15kW  17kW 

Inverter

 

Installation bracket

 

Quick installation guide

 

Communication 

connector

 

Expansion bolt   

6(M8*60) 

Hex bolt M8*20 

Hex bolt M6*16 

DC connector 

AC connector 

Hole template 

Before installation 

2.1 Installation place 

Select installation place based on the following considerations:

  

 

Figure 1 Installation space(mm) 

(1) The environment temperature is between -25

~60

(2) The installation surface should be perpendicular to the horizontal 

line. Refer to Figure 2. 

 

Figure 2 Installation position 

2.2 Cable specifications 

The user can select connection cable according the table below: 

Table 2 Cable specifications 

Models 

DC side 

AC side 

Cross-section 

mm² 

  (length

≤50m)

 

Cross-section 

mm² 

  (length >50m)

 

Cross-section 

mm²

 

(length

≤50m)

   

L

 

N/PE

 

6kW/7kW/ 

8kW /9kW /     

10kW /12kW / 

15kW/17kW   

10 

Mechanical installation 

Take the typical installation environment as the example, the manual   

describes how to install the inverter on concrete wall. . 

 

Figure 3 Installation bracket of the inverter

 

Table 3 Size of installation bracket 

Model

 

Installation hole

 

A(mm)

×

B(mm) 

6kW / 7kW / 8kW /9kW / 

10kW /12kW / 15kW/17kW

 

400

×400 

Installation steps of three-phase inverter: 

(1) Locate the installation hole with the installation bracket, and then 

use expansion bolts to fix the installation bracket at the proper 

location of the walls;   