b. If the DMX LED is on and no response to the channel, check the
address settings and DMX polarity.
c. If you have intermittent DMX signal problems, check the pins on
connectors or on PCB of the unit or the previous one.
d. Try to use another DMX controller.
e. Check if the DMX cables run near or run alongside to high voltage
cables that may cause damage or interference to DMX interface circuit.
3. Some units don’t respond to the easy controller
a. You may have a break in the DMX cabling. Check the LED for the
response of the master/slave mode signal.
b. Wrong DMX address in the unit. Set the proper address.
4. One of the channels is not working well
a. The stepper motor might be damaged or the cable connected to
the PCB is broken.
b. The motor’s drive IC on the PCB might be out of condition
5. Fixture Cleaning
The cleaning of internal and external optical lenses and/or mirrors must be
carried out periodically to optimize light output. Cleaning frequency depends
on the environment in which the fixture operates: damp, smoky or particularly
dirty surrounding can cause greater accumulation of dirt on the unit’s optics.
12