WHEN USING ELECTRICAL APPLIANCES, BASIC SAFETY PRECAUTIONS
SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, AND INJURY TO PERSONS, INCLUDING THE
FOLLOWING:
1. Check the household voltage to ensure it matches the unit’s rated specification
before operating.
2. Children should be supervised to ensure that they do not play with the
appliance.
3. DO NOT refill the unit from the mist outlet directly, or it will damage the unit.
4. DO NOT allow children to play with any product packaging, such as plastic
bags.
5. To avoid fire hazards, NEVER put the cord under rugs, near heat registers,
radiators, stoves, or heaters.
6. DO NOT place humidifier near heat sources such as stoves, radiators, and
heaters. Do locate your humidifier on an inside wall near an electrical outlet.
The humidifier should be at least 4 inches away from the wall for best results.
7. DO NOT attempt to refill humidifier without unplugging the unit from its electrical
outlet first.
8. DO NOT operate any appliance with a damaged cord or plug, after the
appliance malfunctions, or if it has been dropped or damaged in any manner.
Return appliance to manufacturer for examination, electrical or mechanical
adjustment, or repair.
9. Always place humidifier on a firm, flat, level surface at least 2 feet away from the
floor.
10. DO NOT allow the moisture outlet to directly face the wall.
11. NEVER tilt, move, or attempt to empty unit while it is operating.
12. Shut off and unplug before removing the water tank and moving the unit.
13. DO NOT attempt to repair or adjust any electrical or mechanical functions on
this unit. Doing so will void your warranty. The inside of the unit contains no user
serviceable parts. All servicing should be performed by qualified personnel only.
14. NEVER use detergents, gasoline, glass cleaner, furniture polish, and paint
thinner, or other household solvents to clean any part of the humidifier.
15. Do NOT pour water in any openings other than the water tank.
16. Excessive humidity in a room can cause water condensation on windows and
furniture. If this happens, turn the humidifier OFF.
17. Never place housing under water flow or immerse in liquid.
18. DO NOT use essential oils, hot water, and other additives. For best results, use
filtered or distilled water only.
19. DO NOT operate without tank or if leaking occurs.
20. Clean and dry unit after each use. Always plug and unplug the unit with dry
hands to avoid electric shock.
TROUBLESHOOTING
If your humidifier is not working correctly please check the following causes:
PROBLEM
PROBABLE CAUSE
SOLUTION
Humidifier does not
operate.
Power cable not plugged
in.
Plug in power cable.
The power light is
on, but there is no
mist.
No water in water tank.
Fill tank with water.
The water mist
produces an
unpleasant smell.
Dirty water or the water
was left in the water tank
for too long.
Open the water tank and
leave it for 12 hours in a
shady and cool place.
Clean the water tank and
change the water.
The power light is
on, but the
humidifier doesn’t
work
Too much water in the
basin.
Turn off the unit and remove
water from basin. Check if
O-ring seal in the water cap is
seated properly. Check for
leaks before use.
The mist output
volume is low
The transducer is dirty.
Clean transducer with a
soft-bristle brush.
Water is too dirty or
water was kept too long
in the tank
Clean water tank and change
the water
Abnormal noise
Resonance caused
when water level is too
low.
Fill the water tank.
Unit is on an unstable
surface.
Move the unit to a flat stable
surface.
Very tight tank cap
Cap Overtightened.
Add liquid soap to O-ring on
the water cap to ease
opening for future use.
Water leaking
Water tank gasket not
seated properly or water
tank/basin has been
compromised.
Check if O-ring seal on the
water cap is seated properly
in the water cap to prevent
leaking. Check for leaks
before use. If leak continues,
do not use. Unplug and
contact manufacturer.
Model No: 2516