2

 

Quick Configuration 

2.1

 

System Login and Logout   

Enter the device IP address in the address bar of the Firefox browser or Google Chrome 
(device default IP:192.168.0.120, the IP is showing on device panel.), press Enter to open 
the login page, as shown in Figure 2-1. 

Figure 2-1

 

Login interface 

 

Enter the username and password (the default username is admin),    user must activation at 
first to login, set the Passwoard and security configuration questions, as shown in Figure 2-
2. 

Switch the language at the page as shown in Figure 2-1.. 

Summary of Contents for SEC-TEMPTERMINALTP

Page 1: ...Issue V1 0 Date 2021 02 22 Face Recognition Terminal SEC TEMPTERMINALTP User Manual...

Page 2: ......

Page 3: ...rs which if not avoided may cause minor or moderate injuries It alerts you to risks Neglect of these risks may cause device damage data loss device performance deterioration or unpredictable results I...

Page 4: ...half hour so that the measurement temperature is normal powered on for more than 1 5 hours is the best status Avoid heavy loads intensive shakes and soaking to prevent damages during transportation an...

Page 5: ...nformation that is not accurate enough or product function and operation description that is slightly inconsistent with the actual product The manufacturer will update this manual according to product...

Page 6: ......

Page 7: ...strctions 15 2 Quick Configuration 16 2 1 System Login and Logout 16 2 2 Modify the Password 18 2 3 Preview Interface 20 2 3 1 Download VLC 20 2 3 2 Live Video Interface 21 3 Configuration Setting 23...

Page 8: ...ice 38 3 6 4 SMTP 39 3 7 UI Sound Settings 40 3 8 Temperature Parameters 44 3 9 Access Condition 45 3 10 Upgrade and Maintenance 48 4 Face Database 51 4 1 Add Face 51 5 Capture History 54 6 UI Panel S...

Page 9: ...camera Anti fake function for pictures and videos Temperature measuring distance 0 5 to 1 2 m response speed 100ms Face recognition distance 0 3 to 2 0 m Use of deep learning algorithms to support a...

Page 10: ...xceed 20 m If 1 5 mm standard cable is used 12V switching power supply is used and the wiring distance from the site construction switching power to equipment distance does not exceed 30 m If 2 0 mm s...

Page 11: ...Cable description ID Description Description Remarks 1RJ45 Network port Connect to Ethernet Doesn t support POE 2POWER Power Connect to DC 12V 3GATE COM Connect to Access control s COM Access control...

Page 12: ...ine 2 3 Connect to alarm device line 3 G GND 6ALARM OUT Alarm out COM negative Alarm OUT Alarm out positive 7GATE 485 G GND P Connect to alarm light negative The positive of alarm light needs be conne...

Page 13: ...cover on forehead It is recommended to start measure temperature after 30 minutes being powered on Please wait for 2 3 minutes before measuring temperature when coming from outdoors or other environme...

Page 14: ...Face Recognition Terminal User Manual 8 Issue V1 1 2021 02 22 Figure 1 4 Dimensions unit mm...

Page 15: ...the steel plate opening is 34 mm the specific position depends on the situation When the all in one is installed in the factory configuration the elevation angle is about 5 Figure 1 6 Position of ope...

Page 16: ...umn Procedure of installing at the gate Drill a hole with the diameter of 34mm on the gate machine according to Table 1 2 Figure 1 Remove the nut on the column of the integrated machine and pass the t...

Page 17: ...Face Recognition Terminal User Manual Issue V1 1 2021 02 22 11 Figure 1 7 Fix steel plate 1 2 3 4...

Page 18: ...the accessory is optional following with the different installment Figure 1 8 Dimensions 53 9 28 75 44 75 15 19 36 35 32 75 4 5 68 1 4 1 4 3 5 12 1 32 25 80 2 The installation method is to first inst...

Page 19: ...the wall as the dimensions of the wall bracket insert the rubber plug into the hole and reserve a cable hole on the wall Fix the wall mount bracket to the wall plug with 4 self tapping screws and firs...

Page 20: ...4 Issue V1 1 2021 02 22 After the device falls to the final position tighten the middle screw at the bottom of the device Figure 1 10 Wall mounting no the passing cables hole Groo ve Wa ll bra cket s...

Page 21: ...o the groove on the back of the camera After the device falls to the final position tighten the middle screw at the bottom of the device The installation height should choose the appropriate face heig...

Page 22: ...Chrome device default IP 192 168 0 120 the IP is showing on device panel press Enter to open the login page as shown in Figure 2 1 Figure 2 1 Login interface Enter the username and password the defau...

Page 23: ...the login page by clicking the Exit button in the top right corner of the page If you have forgotten your password you can answer the security configuration questions to verify identity set the new p...

Page 24: ...gnition Terminal User Manual 18 Issue V1 1 2021 02 22 Figure 2 4 Forgetting password End 2 2 Modify the Password At Configuration System User Management interface to modify the password as shown in Fi...

Page 25: ...ition Terminal User Manual Issue V1 1 2021 02 22 19 Figure 2 5 User Management Choose the user name from the user list click Modify to change a new password as shown in Figure 2 6 Figure 2 6 Modify pa...

Page 26: ...eview Interface 2 3 1 Download VLC Enter the web interface as shown in Figure 2 7 User need to download the VLC player at first login Figure 2 7 Download VLC Following the reminder to download the VLC...

Page 27: ...not user can Click to preview the live video will showing 2 3 2 Live Video Interface The page setting items of the notify sound and interface are as shown in Figure 2 9 Figure 2 9 Preview interface 1...

Page 28: ...Face Recognition Terminal User Manual 22 Issue V1 1 2021 02 22 4 Logout leave out the current account End...

Page 29: ...iew the device model device serial number hardware version web version thermal serial thermal SDK version as shown in Figure 3 1 Figure 3 1 Basic information 3 2 System Setting At System interface use...

Page 30: ...ssue V1 1 2021 02 22 Figure 3 2 Time configuration page There are two modes to set time NTP timing and manual timing 3 2 2 Logo Settings At Configuration System Logo Setting interface User can custom...

Page 31: ...erminal User Manual Issue V1 1 2021 02 22 25 Figure 3 3 Logo settings End 3 2 3 User Management At Configuration System User Management interface user can modify the security question and password as...

Page 32: ...nal User Manual 26 Issue V1 1 2021 02 22 Figure 3 4 User management interface Click Security question the pop up window shows as following input the password to enter security configuration questions...

Page 33: ...27 Figure 3 5 Security qusetion Choose the questions and input the answers if the password was forgot you can use the security questions to verify identity and set the new password Choose the admin u...

Page 34: ...Figure 3 6 User modify End 3 2 4 System Parameters At Configuration System System Parameters interface set the parameters of system Normal Setting Attribute Settings Recognize Settings Capture Timing...

Page 35: ...gnize Settings Set the recognition interval milliseconds Setting method Drag the slider EMMC storage Validity Enable the validity you can set the timing duration day Setting method Tick Input the valu...

Page 36: ...delete all snapshot history Setting method Click End 3 2 5 Questionnaire At Configuration System Questionnaire interface as shown in Figure 3 8 Figure 3 8 Questionnaire interface Enable the function...

Page 37: ...ure 3 9 Questionnaire User can add the questions input the question into the input box click Add to add the question the questions will show in list End 3 3 Video Settings At Configuration Video inter...

Page 38: ...ings The device is restarted login again and the settings take effect End 3 4 Image Settings At Configuration Image interface user can set display settings and exposure Area ROI as shown in Figure 3 1...

Page 39: ...of an image As the value increases the borders become clearer and the number of noise points increases Setting method Drag the slider Default value 50 Saturation It indicates the color saturation of...

Page 40: ...2 Figure 3 12 Digital wide dynamic page Exposure Settings Tick Enable Exposure Limit to enable the function as shown in Figure 3 13 Figure 3 13 Exposure settings page Face Auto Exposure Settings Figur...

Page 41: ...mask link no match alarm link questionnaire alarm link set alarm duration as shown in Figure 3 16 User should connect the alarm IO output port to external alarm device at first Figure 3 16 Alarm linka...

Page 42: ...m linkage Email End 3 5 3 Alarm Input At Configuration Alarm Alarm Input interface user can enable the alarm input Choose the alarm index it depends on which alarm input port is used choose the trigge...

Page 43: ...3 6 Network Service 3 6 1 TCP IP At Configuration Network Service TCP IP interface user can set the TCP IP parameters as shown in Figure 3 19 Figure 3 19 TCP IP configuration interface You can tick t...

Page 44: ...3 20 Device Port Configuration interface Input the http port default is 80 and RTSP port default is 554 Click Save to save the settings You will need to login the web using the new port after changin...

Page 45: ...Server settings interface Picture Upload Settings User can choose different pictures to upload tick background image upload capture image upload infrared image upload register image upload End 3 6 4 S...

Page 46: ...server address of Email SMTP Server Port The server port of Email Username Password The username of Email The password of Email Sender Email Address The sender address of Email Recipient Email Address...

Page 47: ...Face Recognition Terminal User Manual Issue V1 1 2021 02 22 41 Figure 3 23 UI Sound interface...

Page 48: ...prompt sound settings The camera will broadcast the set voices when it detects mask is not worn as shown Figure 3 24 Setting method Tick and choose the file Normal Temperature Scene Enable choose sou...

Page 49: ...ce Match Result compare the captured face with the person in the registered database if it is a registered person display relevant information on the UI interface such as name work ID etc Show Tempera...

Page 50: ...inal User Manual 44 Issue V1 1 2021 02 22 Figure 3 28 Questionnaire Warning Scene End 3 8 Temperature Parameters At Configuration Temperature Parameters interface set the parameters of temperature as...

Page 51: ...how on the UI panel Click Shutter Adjust to test the sheet of infrared Setting method Tick Click to restart the shutter Temperature Parameters Set the unit of temperature min temperature max temperatu...

Page 52: ...Face Recognition Terminal User Manual 46 Issue V1 1 2021 02 22 Figure 3 30 Access condition interface...

Page 53: ...perature meets the set conditions the door can be opened Mask guest No need to register person who only just wear a mask can open the door Body temperature mask Only registered personnel who meet the...

Page 54: ...48 Issue V1 1 2021 02 22 Figure 3 31 Wiegand input interface Figure 3 32 Wiegand output interface End 3 10 Upgrade and Maintenance At Configuration Upgrade and Maintenance interface user can upgrade a...

Page 55: ...ge of web as shown in figure Reboot Reboot the device click Reboot on the pop up window click OK wait few seconds the device will restart Reset Reset the device click System Recovery to recover device...

Page 56: ...50 Issue V1 1 2021 02 22 Browse the local folder where the upgrade software locates click Upgrade to upgrade the device The upgrade process takes 1 10 minutes do not power off the device it will auto...

Page 57: ...ce database as shown in Figure 4 1 Click to edit the face database Click to delete database 4 1 Add Face At Face Database interface user can add the person to database one by one or import the face da...

Page 58: ...sword is used for UI panel to unlock by password Tick the persons want to be delete click Delete to delete Click Export to export the data to local folder the status is showing as Figure 4 3 Figure 4...

Page 59: ...21 02 22 53 Figure 4 4 Search person Click to modify the information as shown in Figure 4 5 Click OK to save the changes Figure 4 5 Modify personal information Click to delete the person information t...

Page 60: ...ions such as temperature range name ID mask it will show capture time FIG sheet mask temperature and the scanning result as shown in Figure 5 1 Figure 5 1 Capture History interface The char of tempera...

Page 61: ...Face Recognition Terminal User Manual Issue V1 1 2021 02 22 55 Figure 5 2 Set detail time User can set the detail time to search End...

Page 62: ...iguration data record temperature measurement configuration access control settings network configuration system settings and so on the home page as shown in Figure 6 1 Figure 6 1 UI panel settings 6...

Page 63: ...guration Click to add face library Enter one library to operate add modify or edit person information to library or set filter to search personnel 6 2 Data Record At data record interface user can ret...

Page 64: ...Face Recognition Terminal User Manual 58 Issue V1 1 2021 02 22 Figure 6 3 Data record Input the conditions of querying click start search to search the result will show on screen...

Page 65: ...nt Configuration At temperature measurement configuration interface user can set FFC control and temperature parameters as shown in Figure 6 4 Temperature measurement configuration 6 4 Access Control...

Page 66: ...ss control Set the unlock condition such as enable temperature enable mask enable guest or set weigand weigand out or weigand in more detail can refer to chapter 3 9 6 5 Network Configuration At netwo...

Page 67: ...e V1 1 2021 02 22 61 Figure 6 6 Network configuration 6 6 System Settings At system settings interface user can view the information of device set date and time set privilege of user set local configu...

Page 68: ...mation device name device number device model device serial number hardware version SDK version ARSTACK version software version Date and time includes set time zone start NTP set time Local configura...

Reviews: