 | tipi installation and User ManUal

2. pre-installation

congratulations on your purchase of the Tipi. This appliance should be installed and checked by a qualified 
professional. ensure you have read the operation guidelines thoroughly prior to first use. For any questions or concerns 
please contact oblica on 03 9416 0400. 
The installation process is outlined below:
 

– Determine position of firebox and flue carefully observing the clearances described within this section

 

– install the external flue

 

– install the internal flue and engage the firebox

 

– ensure the floor has adequate protection

caution:

Using components or parts other than those provided by the manufacturer or modifying the specification of components 
may result in inferior or unsafe operation. if such action is necessary, consult the manufacturer in the first instance. 
 

Warning: 

•  The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the 

relevant building code or codes.

•  Any modification of the appliance that has not been approved in writing by the testing authority 

will be in breach of the approval granted for compliance with AS/NZS 4013.

•  Once the flue has been installed and approved by a professional installer, the flue must not be 

modified in any way.

Summary of Contents for tipi

Page 1: ...tipi model specifications 1 Technical Data 2 2 PRE Installation 3 3 INSTALLATION 5 4 Operation 9 5 TestING 10 Keep for future use...

Page 2: ...ta Determined under test conditions Nominal thermal output 10kW Efficiency Australian Test 57 Emissions Australian Test 1 6 g Kg FLUE Standard8 754 1585 Weight and dimensions Dimensions Firebox W754 x...

Page 3: ...flue and engage the firebox Ensure the floor has adequate protection Caution Using components or parts other than those provided by the manufacturer or modifying the specification of components may re...

Page 4: ...please contact our office on 03 9416 0400 or email info oblica com au IMPORTANT Frames must also be considered Timber window frames must be treated as combustible surfaces see 2 3 Aluminium frames ca...

Page 5: ...Installation and User Manual 3 InstallATION 3 1 Typical flue kit installation Cowl Chinaman Hat 10 Outer Case 12 Outer Case 10 Outer Case 12 Outer Case 8 Active Flue 8 Active Flue CEILING RING RUBBER...

Page 6: ...stalled as per Australian standards see diagrams below The top of the flue must be 400mm higher than the highest point of the roof Alternatively there must be a minimum distance of 8 meters from any h...

Page 7: ...the combustible material with non combustible material laid directly onto the concrete 100mm Joist Insulative board 6mm non combustible finish Non combustible fin eg tiles Concrete Combustible floor e...

Page 8: ...Combustible floor eg timber 100mm 300mm DOORS Combustible floor eg Timber Floor protector 100mm 100mm Non combustible finish eg tiles Concrete Combustible floor eg timber 100mm 300mm DOORS Combustible...

Page 9: ...s to start or rekindle the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of...

Page 10: ...determination of Power Output and Efficiency and AS NZS 4013 1999 for Flue Gas Emission using hardwood fuel issue DATE 8 7 2014 INVESTIGATING OFFICER Steve Marland RESULTS The appliance particulate em...