Invicta tipi Installation Manual Download Page 1

tipi: 

model specifications

1. Technical DaTa 

2

2. PRe-insTallaTion 

3

3. insTallaTion 

5

4. oPeRaTion 

9

5. TesTinG 

10

Keep for future use

Summary of Contents for tipi

Page 1: ...tipi model specifications 1 Technical Data 2 2 PRE Installation 3 3 INSTALLATION 5 4 Operation 9 5 TestING 10 Keep for future use...

Page 2: ...ta Determined under test conditions Nominal thermal output 10kW Efficiency Australian Test 57 Emissions Australian Test 1 6 g Kg FLUE Standard8 754 1585 Weight and dimensions Dimensions Firebox W754 x...

Page 3: ...flue and engage the firebox Ensure the floor has adequate protection Caution Using components or parts other than those provided by the manufacturer or modifying the specification of components may re...

Page 4: ...please contact our office on 03 9416 0400 or email info oblica com au IMPORTANT Frames must also be considered Timber window frames must be treated as combustible surfaces see 2 3 Aluminium frames ca...

Page 5: ...Installation and User Manual 3 InstallATION 3 1 Typical flue kit installation Cowl Chinaman Hat 10 Outer Case 12 Outer Case 10 Outer Case 12 Outer Case 8 Active Flue 8 Active Flue CEILING RING RUBBER...

Page 6: ...stalled as per Australian standards see diagrams below The top of the flue must be 400mm higher than the highest point of the roof Alternatively there must be a minimum distance of 8 meters from any h...

Page 7: ...the combustible material with non combustible material laid directly onto the concrete 100mm Joist Insulative board 6mm non combustible finish Non combustible fin eg tiles Concrete Combustible floor e...

Page 8: ...Combustible floor eg timber 100mm 300mm DOORS Combustible floor eg Timber Floor protector 100mm 100mm Non combustible finish eg tiles Concrete Combustible floor eg timber 100mm 300mm DOORS Combustible...

Page 9: ...s to start or rekindle the fire Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating Do not store fuel within prescribed installation clearance distances The use of...

Page 10: ...determination of Power Output and Efficiency and AS NZS 4013 1999 for Flue Gas Emission using hardwood fuel issue DATE 8 7 2014 INVESTIGATING OFFICER Steve Marland RESULTS The appliance particulate em...

Reviews: