20. PROPERLY SUPPORT LONG OR WIDE WORKPIECES. Loss of control of the workpiece can cause serious
injury.
21. NEVER PERFORM LAYOUT, ASSEMBLY or set-up work on the table/work area when the machine is running.
Serious injury will result.
22. TURN THE MACHINE “OFF”, DISCONNECT IT FROM THE POWER SOURCE, and clean the table/work
area before leaving the machine. LOCK THE SWITCH IN THE “OFF” POSITION to prevent unauthorized use.
Someone else might accidentally start the machine and cause injury to themselves or others.
ADDITIONAL SPECIFIC SAFETY RULES
SAVE THESE INSTRUCTIONS.
Refer to them often and use them to instruct others.
POWER CONNECTIONS
A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and
should be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords
which have 3- prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before
connecting the machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the
electric current is of the same characteristics as indicated on the machine. All line connections should make good
contact. Running on low voltage will damage the machine.
DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.
MOTOR SPECIFICATIONS
The 22-610 has a 10 HP three phase motor that comes wired at 230 volts and 60 HZ alternating current. The motor
is also capable of being wired for 460 volt operation, but this connection must be done by a qualified electrician and
conform to the National Electric Code and all local codes and ordinances.
GROUNDING INSTRUCTIONS
These machines are not supplied with power cords and they are intended to be permanently connected to the
building’s electrical system. All wiring must be done by a qualified electrician and conform to the National Electric
Code and all local codes and ordinances. For wiring instructions, see section “ELECTRICAL CONNECTIONS” in
this manual.
FUNCTIONAL DESCRIPTION
FOREWORD
The Invicta Industrial Model DGI-63D Planer with a 10 HP, three-phase motor capable of 230 volt or 460volt
operation with an LVC magnetic starter and automatic reset overload protection; 4-knife cutterhead, infeed and
outfeed rollers, chipbreakers, dust chute, knife-setting gauge and wrench.
NOTICE: THE PHOTO ON THE MANUAL COVER ILLUSTRATES THE CURRENT PRODUCTION MODEL. ALL
OTHER ILLUSTRATIONS CONTAINED IN THE MANUAL ARE REPRESENTATIVE ONLY AND MAY NOT
DEPICT THE ACTUAL COLOR, LABELING OR ACESSORIES AND ARE INTENDED TO ILLUSTRATE
TECHNIQUE ONLY.