STIMO Wood burner
reference P610144
Author: XD , 18/02/2020
Page 3 of 11
APPLIANCE INSTALLATION INSTRUCTIONS.
To limit heating the walls neighbouring the wood burner to 65K (K = degrees Celsius above room temperature), the minimum
distances indicated in the diagram below must be followed.
If the neighbouring walls are made from non-combustible materials that are not damaged by heat ( the wall temperature can reach
200°C), these distances can be reduced to 150 mm.
WOOD BURNER INSTALLATION TOP VIEW
500
mm
Back
wall
Side
wall
500
mm
500 mm
Back wall
Concrete slab
Stainless
steel plate