Series and Parallel of batteries

There are strict conditions under which the Invicta 
Lithium Range can be configured into Series OR Parallel 
systems. Please note these conditions below.
•   Not all SNL batteries can be configured into a Series 

or parallel system. Please note the part number of 
the battery. If the Part number contains an “S” suffix 
example SNL12V100S. Then this denotes that the 
battery can be configured into a system of up to, but 
not exceeding 4 batteries in Series.

•   If the part number does not end in an “S” for example 

SNL12V100BT, then series configuration is strictly 
prohibited.

•   All Invicta lithium batteries can be configured into a 

parallel configuration up to 4 units in parallel under the 
conditions outlined below.

Parallel Configuration

1.   Ensure all batteries to be in the parallel configuration 

have been fully charged individually by matched 
chargers.

2.   Ensure OCV of each battery is less than  

<0.2V of each other.

3.   After charging, set aside and allow to rest for 8 hours.
4.  Utilising wires of circumference large enough to carry 

required current (>100A), connect the batteries in 
the above (Fig 1) configuration. Ensure all connecting 
cables lengths are of the same length.

5.   Be careful not reverse connect the Positive and 

Negative.

6.   Ensure correct charge voltage and current is utilised 

for configuration.

7.   Max Charge Voltage -  SNL12V… 14.6V / SNL24V…. 

29.2V.  

8.   It is absolutely prohibited to series a paralleled 

configuration.

9.   Once in Parallel configuration ensure a full charge is 

completed a min of every 3months

10.  Once in Parallel configuration, the system must be 

charged and discharged as a system. If one batteries 
needs to be replaced, the whole system will require 
replacing.

Series Configuration

1.   Check Part number contains an “S” on end 

to ensure the battery is suitable for Series 
configuration.

2.   Ensure all batteries to be in the series 

configuration have been fully charged individually by 
matched chargers

3.   Ensure OCV of each battery is less than <0.2V of each 

other.

4.  After charging, set aside and allow to rest for 8 hours.
5.   Utilising wires of circumference large enough to carry 

required current (>100A), connect the batteries in the 
above (Fig 2) configuration. Ensure all connecting 
cables lengths are of the same length.

6.   Be careful not reverse connect the Positive and 

Negative.

7.   Ensure correct charge voltage and current is utilised 

for configuration:  
A. SNL12V… 14.6V / SNL24V…. 29.2V 
B. Two batteries in Series – 29.2 
C. Three Batteries in Series – 43.8V 
D. Four Batteries in Series – 58.4V

8.   It is absolutely prohibited to parallel a series 

configuration.

9.   Once in Series configuration ensure a full charge is 

completed a min of every 3months

10.  Once in Series configuration, the system must be 

charged and discharged as a system. If one batteries 
needs to be replaced, the whole system will require 
replacing.

ANODE

PACK 4

PACK 1

CATHODE

FIG 2

ANODE

PACK 4

PACK 1

CATHODE

FIG 1