SAFETY 

 

 

When  in  use,  all  the  appliance  surfaces  are  hot:  Beware  of  burns!!  Avoid  installing  the  appliance  in  a  location 
where there is a lot of passage. 

 

If a chimney fire were to break out, first close the loading door, then the primary and secondary air intakes, then 
immediately contact your local fire & rescue services (In the UK, dial 999). 

 

Never  load  the  appliance with more wood  than  indicated  in the  “use  advice”  (i.e. less than  half  the  combustion 
chamber height). Using the appliance as an incinerator is prohibited. 

 

The use of non-recommended fuels or fuel not adapted to it, including liquid fuels, is prohibited. 

 

The combustion chamber should always remain closed, except during re-loading. Do not overheat the appliance. 

 
CONNECTION 
 

DETAIL ADAPTATEUR FUMISTERIE

POUR GARANTIR LE BON FONCTIONNEMENT
DE LA CLE DE BUSE, MERCI DE DECOUPER
L'ADAPTATEUR FUMISTERIE AUTOUR DE
L'AXE DU VOLET

 

 

Firing rate control

 

 
 
 
 
 
 

 

 

 

 

 
 
 
 

 
 
 
 
 
 
 
 
 

CLOSED POSITION

 | 

OPEN POSITION

 

FLUE ADAPTER DETAIL

 

TO GUARANTEE THE CORRECT OPERATION 
OF THE FLUE KEY. PLEASE CUT THE FLUE 
ADAPTER AROUND THE FLAP SHAFT

 

Summary of Contents for 6771 75

Page 1: ...Foyer 700 OPT cl de buse r f rence 677175 R dacteur FL le 13 11 2018 Page 1 sur 10 Foyer 700 Optimis avec cl de buse ref 6771 75...

Page 2: ...Combustible recommand Bois b ches de 25 cm longueur maximale possible 53 cm D bit massique des fum es 7 6 g s Distance par rapport aux mat riaux combustibles adjacents Lat ralement 13 cm dont 5 cm d i...

Page 3: ...de respecter le principe des dispositions du sch ma ci apr s Respecter les dimensions minimales d encastrement et du circuit d air de convection section d entr e de l air chauffer et section de sortie...

Page 4: ...Foyer 700 OPT cl de buse r f rence 677175 R dacteur FL le 13 11 2018 Page 4 sur 10 2 3 4 5 7 8 9 10 11 12 14 17 18 19 21 22 23 24 25 26 27 28 29 30 31 16 11 12 15 16 16 20 1 6 13 16...

Page 5: ...TEUR AT700160A 9 1 REGISTRE AT700363A 10 1 BOUTON AS610318A 11 4 RONDELLE M M06 AV4100060 12 8 RONDELLE L M6 AV4110060 13 1 RONDELLE ONDULEE D8 AV417008 14 1 ECROU H M6 AV7130060 15 2 ECROU BORGNE M6...

Page 6: ...re des fum es REP QTE DESIGNATIONS REFERENCES 1 1 BOUTON INOX AS610232 2 1 AXE VOLET AS700100 3 1 TIGE VOLET AS700411 4 1 EQUERRE VOLET AT700679 5 2 RONDELLE M10 AV4100100 6 2 RONDELLE M6 AV4216250 7...

Page 7: ...eu mod r afin de permettre une dilatation normale de l ensemble de l appareil Pour faciliter l allumage nous vous conseillons de conserver un lit de cendres sur la grille qui par la m me occasion sero...

Page 8: ...allure au del de la position allure normale permet d obtenir un suppl ment d air pour l allumage Cette position est r serv e aux op rations d allumage et de reprise et ne doit pas tre maintenue plus...

Page 9: ...ttre dans l appareil des charges de bois sup rieures celles indiqu es dans les conseils d utilisation soit moins de la moiti de la hauteur de la chambre de combustion Il est interdit d utiliser l appa...

Page 10: ...r f rence 677175 R dacteur FL le 13 11 2018 Page 10 sur 10 DECENDRAGE Utiliser une pelle m tallique transversalement pour vider les cendres qui s accumulent dans la chambre de combustion au cours des...

Page 11: ...OPT 700 Insert flue key r f rence 677175 R dacteur FL le 13 11 2018 Page 1 sur 11 Optimised 700 Insert with flue key ref 6771 75...

Page 12: ...ture 304 C Running mode Intermittent Recommended fuel Wood 25 cm logs maximum possible length 53 cm Smoke mass flow 7 6 g s Distance from adjacent combustible materials Laterally 13 cm including 5 cm...

Page 13: ...be followed Respect the minimum embedding and convection air circuit dimensions size of the intake for the air to be heated and hot air outlet size The indicated minimum embedding dimensions guarante...

Page 14: ...OPT 700 Insert flue key r f rence 677175 R dacteur FL le 13 11 2018 Page 4 sur 11 2 3 4 5 7 8 9 10 11 12 14 17 18 19 21 22 23 24 25 26 27 28 29 30 31 16 11 12 15 16 16 20 1 6 13 16...

Page 15: ...0160A 9 1 CONTROL AT700363A 10 1 KNOB AS610318A 11 4 M06 M WASHER AV4100060 12 8 M6 W WASHER AV4110060 13 1 WAVED D8 WASHER AV417008 14 1 H M6 NUT AV7130060 15 2 M6 CAP NUT AV7140060 16 12 M6 FLANGE N...

Page 16: ...trol detail PART QTY NAME REFERENCE 1 1 STAINLESS STEEL KNOB AS610232 2 1 FLAP SHAFT AS700100 3 1 FLAP ROD AS700411 4 1 FLAP BRACKET AT700679 5 2 M10 WASHER AV4100100 6 2 M6 WASHER AV4216250 7 1 M5 NU...

Page 17: ...urning you can load your appliance During the first hours of use we recommend a moderate fire to allow the entire appliance to dilate normally To make lighting easier we recommend keeping a bed of ash...

Page 18: ...sing the firing rate control beyond the normal firing rate position provides additional air for lighting This position is reserved for lighting and re starting operations and must not be used for more...

Page 19: ...dicated in the use advice i e less than half the combustion chamber height Using the appliance as an incinerator is prohibited The use of non recommended fuels or fuel not adapted to it including liqu...

Page 20: ...700 Insert flue key r f rence 677175 R dacteur FL le 13 11 2018 Page 10 sur 11 REMOVING ASH Use a metal shovel and a side movement to empty the ash that accumulates in the combustion chamber during u...

Page 21: ...eil l installation doit avoir Une alimentation en air frais d di la combustion Une vacuation des produits de combustion L appareil et l installation doivent tre entretenus r guli rement Toutes les sur...

Reviews: