Power saving mode
enable/disable
Saving mode disable
(default)
If disabled, no matter connected load
is low or high, the on/off status of
inverter output will not be effected.
Saving mode enable
If enabled, the output of inverter will
be off when connected load is pretty
low or not detected.
05
Battery type
AGM (default)
User-Defined
If “User-Defined” is selected, battery
charge voltage and low DC cut-off
voltage can be set up in program 19,
20 and 21.
Flooded
Lithium
(Only suitable when communicated with BMS)
06
Auto restart when
overload occurs
Restart disable (default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable (default)
Restart enable
08
Output voltage
230V (default)
220V
240V
208V
09
Output frequency
50Hz (default)
60Hz
10
Number of series
batteries connected
(e.g. Showing batteries are connected in 2 series)
11
Maximum utility
charging current
24V 3KVA model: default 20A, 20A/30A Settable
(If Li is selected in Program 5, this program can’t be set up)