background image

 

SOLAR WATER PUMP 

DC CONTROLLER

 

User Manual 

 

 

 
 
 
 
 

inverter

.com 

Email:

 [email protected] 

Web:

 https://www.inverter.com/ 

Tel:

 +1 800-585-1519 (Toll-free) 

Summary of Contents for DF-110

Page 1: ...SOLAR WATER PUMP DC CONTROLLER User Manual inverter com Email sales inverter com Web https www inverter com Tel 1 800 585 1519 Toll free...

Page 2: ...lity 4 For the perfect performance and long life working the DC controller should be kept away from strike shake sunshine salt mist oil mist and etc 5 Because of the power loss from cable try to use t...

Page 3: ...3 2 Solar Water Pumping System Installation Diagram 4 3 3 Solar DC Controller Wiring Diagram 4 3 4 Wiring Instructions 5 4 Operation 5 4 1 Operation Panel 5 4 2 Key Instructions 6 4 3 Test Running 6 4...

Page 4: ...l Property Controller and Pump Matching Method Controller Model Adaptable Pump Max Input Current A Max Open Voltage V MPPT Voltage Range V Working Temperature DF 12 Rated 12V Pump 15 48 30 48 15 60 DF...

Page 5: ...voltage will decrease this voltage is called working voltage Vmp The Vmp of solar cell needs to be selected according to the solar pump controller s working voltage and then to confirm the open circu...

Page 6: ...Current 9A Open Circuit Voltage 22V Max Power Current 8 4A Max Power Voltage 18V 265W Max power 265W Short Circuit Current 8 7A Open Circuit Voltage 36 6V Max Power Current 7 68A Max Power Voltage 30...

Page 7: ...4 3 2 Solar Water Pumping System Installation Diagram 3 3 Solar DC Controller Wiring Diagram...

Page 8: ...ery Be careful not to reverse or short the terminals We advise you remove all metal wrist bands or watches before you start 2 Solar PV panels connecting together can also produce a lot of energy So op...

Page 9: ...Before you testing the pump the controller box switch must be in the off position The pump must be under water at all times and should have been pre conditioned for at least 15minutes Water is the lu...

Page 10: ...tions 2 Key to start In shutdown state press the ON OFF key to turn on the pump without testing water tank without any shutdown conditions 3 Water shortage to start If the system boot but the pump sto...

Page 11: ...t is closer to the maximum working point If the flashing frequency is slower or not it indicates that the maximum power point is being tracked Solar power is insufficient the pump speed will continue...

Page 12: ...se rewiring to ensure it reliable contact Automatically remove after 30s P46 Stall Protection 1 Motor model is mismatch please choose matching pumps 2 Pump extension cord is too long please reduce the...

Page 13: ...mperature of controller MCU is more than 90 Automatically clear after the temperature is normal E8 Current Sampling Failure Cut off the power and restart after 30 seconds Restart the power PL Power Sh...

Reviews: