MECHANICAL INSTALLATION

 

 

1) Option Module inserted into Optidrive 
Option Module Port 
 
2) DO NOT use undue force in inserting the 
option module into the options port. 
 
3) Ensure the option module is fitted 
securely before powering on the Optidrive. 
 
4) Remove terminal block header from 
option module prior to tightening 
connections. Replace when wiring is 
completed. Tighten to Torque setting 
provided in Specifications. 

 

Option Module Slot 

 

 

 

          Option Module 

OPTION MODULE CONNECTION TERMINALS 

 

 

Pin 

Function 

Extended Digital Input 1 (DI6) 

Extended Digital Input 2 (DI7) 

Extended Digital Input 3 (DI8) 

NC 

Extended Relay Common 

Extended Relay Normally 
Open Contact 

 

Connection Example 

– Internal Supply Connection 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Connection Example 

– External Supply Connection 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 

 

 

LED STATUS INDICATION 

The Extended I/O module has a Status LED – LED A (Green). 

 

LED A: Constant Green Indication - Modular is OK 

 

LED A:

 Flashing

 Green Indication – No Communication with drive 

 

LED A:

 LED Off In

dication – No power to module 

 

LED B is not used. 

 

LED A 

(Green) 

CONFIGURATION 

Extended Digital Inputs: 

Functionality for the additional digital inputs on the extended I/O option module 
is configured through parameter group 9 of the drive standard parameter set. 
 
Menu group 9 parameters cannot be set until the Digital input function select 
parameter (P1-13) has been set to 0 (used defined I/O set-up).  
Access to Menu group 9 parameters is gained by first setting the advanced 
parameter security code into parameter P1-14. By default the advanced 
parameter security code is set to ‘201’ (P1-14 = 201). 
 
Digital inputs are assigned to drive functions using menu group 9. The following 
functions can be assigned to the extended I/O module digital inputs. The listed 
parameters (functions) should be set to 





, or 



 for configuration 

to the extended I/O option module digital inputs. 
 

Parameter Number 

Description 

P9-01 

Enable input source 

P9-02 

Fast stop input source 

P9-03 

Run (FWD) input source 

P9-04 

Run (REV) input source 

P9-05 

Latch function enable 

P9-06 

Reverse enable 

P9-07 

Reset input source 

P9-08 

External Trip input source 

P9-09 

Terminal ctrl override source 

P9-18 

Speed select input 0 

P9-19 

Speed select input 1 

P9-20 

Speed select input 2 

P9-21 

Preset speed select input 0 

P9-22 

Preset speed select input 0 

P9-23 

Preset speed select input 0 

P9-24 

Acc ramp select input 0 

P9-25 

Acc ramp select input 1 

P9-26 

Dec ramp select input 0 

P9-27 

Dec ramp select input 1 

P9-28 

Remote up input source 

P9-29 

Remote down input source 

P9-30 

Speed limit switch FWD 

P9-31 

Speed limit switch REV 

P9-32 

Fire mode input source 

 

Extended Relay Output: 

Functionality for the extended relay output is 

a fixed configuration set to ‘drive 

Healthy’ function on both the P2 and HVAC drive. 
Alternative functionality for the relay can only be configured through the PLC 
programming functionality in the OptiTools Studio software. The PLC 
functionality is a bolt-on software module available from your local Invertek 
distributor. Parameter 9-41 must be set to 1 (user defined PLC) for PLC 
functionality programming. 
Please refer to the OptiTools studio software for detail on configuring the relay 
functionality through the PLC programming function. 
 

For the Optidrive HVAC drive only

, the extended output relay can be used as 

part of the DOL cascade function and is automatically configured as such 
whenever the cascade function is enabled (P8-14 = 1). The default (drive 
healthy) function is automatically disabled once the cascade function is enabled. 
For a single pump DOL cascade the extended output relay is automatically 
configured for control of the DOL pump and the function of the standard drive 
relay 2 should not be set for DOL control (ensure P2-18 is not set to 8). 
For a dual pump DOL cascade the extended output relay is automatically 
configured for control of the DOL pump 2 when the standard drive relay 2 is set 
to control DOL pump 1 (P2-18 is set to 8). 
For Cascade control of more than two pumps (up to max 4) the Cascade option 
model (OPT-2-CASCD-IN) should be used in place of the extended I/O module. 
 

Optidrive Main Control Terminals

Extended I/O Control 

Terminals

7

4

3

2

1

17

18

16

15

14

1

2

3

5

6

+

2

4

V

D

ig

it

a

In

p

u

1

D

ig

it

a

In

p

u

2

D

ig

it

a

In

p

u

3

0

V

R

e

la

y

 2

 

C

o

m

m

o

n

R

e

la

y

 2

 

N

o

rm

a

lly

 O

p

e

n

R

e

la

y

 1

 

C

o

m

m

o

n

R

e

la

y

 1

 

N

o

rm

a

lly

 O

p

e

n

R

e

la

y

 1

 

N

o

rm

a

lly

 C

lo

s

e

d

E

x

te

n

d

e

d

 R

e

la

y

 

C

o

m

m

o

n

E

x

te

n

d

e

d

 R

e

la

y

 

N

o

rm

a

lly

 O

p

e

n

D

ig

it

a

In

p

u

3

D

ig

it

a

In

p

u

2

D

ig

it

a

In

p

u

1

Optidrive Main Control Terminals

Extended I/O Control 

Terminals

7

4

3

2

1

17

18

16

15

14

1

2

3

5

6

+

2

4

V

D

ig

it

a

In

p

u

1

D

ig

it

a

In

p

u

2

D

ig

it

a

In

p

u

3

0

V

R

e

la

y

 2

 

C

o

m

m

o

n

R

e

la

y

 2

 

N

o

rm

a

lly

 O

p

e

n

R

e

la

y

 1

 

C

o

m

m

o

n

R

e

la

y

 1

 

N

o

rm

a

lly

 O

p

e

n

R

e

la

y

 1

 

N

o

rm

a

lly

 C

lo

s

e

d

E

x

te

n

d

e

d

 R

e

la

y

 

C

o

m

m

o

n

E

x

te

n

d

e

d

 R

e

la

y

 

N

o

rm

a

lly

 O

p

e

n

D

ig

it

a

In

p

u

3

D

ig

it

a

In

p

u

2

D

ig

it

a

In

p

u

1

+

-

External Supply 

Source

8-30V DC

Reviews: