SPECIFICATIONS

 

Max Relay switching voltage:      
                                 250V AC / 220V DC 
 
Max Relay switching current:              1A 
Max input voltage :                 +/- 50V DC 
Environmental :               -10ºC … +50ºC 
Conformity :                     IP00,  UL94V-0
 

 

 

 

 

OPTION COMPONENT LAYOUT

 

 
 
 
 
 
 
 
 
 

 

 

EXPLANATION 

 

The HVAC Relay Option Module can be used in applications 
where two indicators are required showing “drive running” 
and “drive tripped”. 
 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Product Suitability 

 

There are 2 variants of this option. The correct variant must be used 
with the following products: 
 

 

Optidrive  

OD-HVACO-IN 

 

 

Optidrive E 

ODE-HVACO-IN 

 
 

Optidrive size 2

Option PCB inserted into 

Optidrive control terminal 

strip. 

 

All 11 terminal screws on 

the Optidrive must be 

tightened to ensure good 

electrical contact and 

correct functionality. 

OPTION MODULE CONTROL TERMINALS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

* Analog inputs should be connected to terminals 6 & 7.   

 

 

 

 

 

 1     2    3    4     5    6     7    8     9   10   11 

0V 

Dig

ita

l In

pu

1

 

   D

ig

it

al

 I

npu

t 2 

   D

ig

it

al

 I

npu

t 3 

+

10V O

u

*

 Anal

og  

Inp

u

*0V 

Analo

g

 Ou

tpu

t

 

0V 

Relay con

tact

 

Re

la

y co

mmo

n

 

 

 

NOTES 

 

 

OPERATION 

 

Programming the first relay output  
 
 

For typical operation set P-18 = 1, eg Relay 2 closed on enable 

(Drive running – Green Light), Relay 1 closed when drive tripped 
(Red Light). 
 
Use the following information to set P-18 for other types of Relay 
output:

 

Since the first relay output (fitted within the Optidrive) is 
programmed using P-18 in the Optidrive, two completely 
independent relay outputs are available.  The following options are 
supported for Relay 1 : 
 
P-18 = 0 

Relay 1 closed when Optidrive disabled 

P-18 = 1 

Relay 1 closed when Optidrive tripped  

P-18 = 2 

Relay 1 closed when Optidrive output not at set 

(requested) speed 

P-18 = 3 

Relay 1 closed when Optidrive output is at zero speed 

P-18 = 4 

Relay 1 closed when Optidrive output is not at maximum 

speed 

P-18 = 5 

Relay 1 closed when Optidrive output is not in overload 

 

Programming the second relay output  

 

The second relay output has only one practical setting - 
 

When P-18 = 1, Relay 2 is closed when Optidrive is running 

 
 

+10

V

 O

/P

 

D

igi

ta

l I

/P 1 

D

igi

ta

l I

/P 2 

D

igi

ta

l I

/P 3 

+10

V

 O

/P

 

An

a

lo

g

 I

/P

 

0V 

An

a

lo

g

 O

/P

 

0V 

R

e

la

y c

ont

ac

R

e

la

y c

o

mmo

n

 

Cl

os

ed

: E

n

a

b

le

; O

p

e

n

: D

is

a

b

le

50

Ω 

m

in. 

0-

10

V an

a

log

 O

/P 

Re

la

y 1 c

o

n

ta

c

ts

 

1 2 3 4 5 6 7 8 9 10 

11 

A

n

a

log

 I

/P

 -

 Cl

os

e

d

: A

; O

p

e

n

 :

V

Cl

o

s

e

d

: P

re

s

et 1; O

p

en

A

n

al

o

g

 I

/P

 

Relay 2 contacts

Relay 2 contacts

 

Reviews: